{"product_id":"regulador-pwm-victron-bluesolar-light-48-10","title":"Victron BlueSolar Light 48-10 10A PWM Charge Controller","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron BlueSolar Light 48-10 10A\u003c\/strong\u003e is a PWM charge controller specifically designed for 48 V photovoltaic systems seeking simplicity, reliability, and battery protection. It incorporates a three-stage charging algorithm (bulk, absorption, and float), output with low voltage disconnect (LVD), and day\/night lighting control with integrated timer. Its seven-segment display makes it easy to set the timer and check the charging status in seconds. Thanks to its low self-consumption and comprehensive electronic protection, it is a robust solution for solar lighting, small off-grid systems, and auxiliary applications at 48 V.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10 A charging current\u003c\/strong\u003e for 48 V systems.\u003c\/li\u003e\n  \u003cli\u003eThree-stage charging: bulk 58.0 V (immediate switch to absorption), absorption 56.8 V, and float 55.2 V.\u003c\/li\u003e\n  \u003cli\u003eLow voltage disconnect (LVD) at 44.8 V with manual reconnection at 50.4 V or automatic at 52.4 V.\u003c\/li\u003e\n  \u003cli\u003eIntegrated lighting control: day\/night detection with programmable timer from the display.\u003c\/li\u003e\n  \u003cli\u003eMaximum PV voltage 100 V, common positive, self-consumption \u0026lt;10 mA.\u003c\/li\u003e\n  \u003cli\u003eProtections: PV\/battery reverse polarity, overload, output short circuit, and overtemperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProtects and extends the life of lead-acid batteries (AGM\/GEL) at 48 V thanks to stage management and precise LVD.\u003c\/li\u003e\n  \u003cli\u003eSimple installation and operation: accessible terminals, clear interface, and settings without the need for external accessories.\u003c\/li\u003e\n  \u003cli\u003eAutomates solar lighting with the built-in timer, reducing costs and components in the panel.\u003c\/li\u003e\n  \u003cli\u003eLow self-consumption maximizes the energy available for loads.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design, ideal for locations with limited space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for autonomous lighting at 48 V, signage, remote stations with low-consumption sensors, small telecom installations, camper\/marine at 48 V, and auxiliary systems requiring a reliable PWM controller with lighting control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharging current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharging stages\u003c\/td\u003e\n\u003ctd\u003eBulk 58.0 V · Absorption 56.8 V · Float 55.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLVD \/ Reconnection\u003c\/td\u003e\n\u003ctd\u003e44.8 V \/ 50.4 V (manual) · 52.4 V (automatic)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. PV (Voc)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLoad output\u003c\/td\u003e\n\u003ctd\u003eManual control + LVD + day\/night timer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCommon positive\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eReverse polarity, overload, short circuit, overtemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-20…+50 °C (full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePermissible humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e6 mm² \/ AWG10 terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e95 × 140 × 33.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with PV panels for 48 V within the 100 V open-circuit limit and with lead-acid batteries (AGM\/GEL) at 48 V. Recommended accessories: DC fuses, disconnectors, surge protection devices, and suitable cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVictron BlueSolar Light 48-10 10A\u003c\/strong\u003e offers simple and safe PWM management, ideal for 48 V systems that prioritize reliability and integrated lighting control.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":51503386034517,"sku":"VICTREG048","price":41.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VICTRON-PWM-LIGHT-48V.png?v=1762631243","url":"https:\/\/aurensol.net\/en\/products\/regulador-pwm-victron-bluesolar-light-48-10","provider":"Aurensol","version":"1.0","type":"link"}