{"product_id":"modulo-bateria-litio-hv-pylontech-fh10050-force-h3","title":"Lithium Battery Module Pylontech HV 5.12kWh FH10050 Force H3","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003ePylontech Lithium Battery Module HV 5.12kWh FH10050 Force H3\u003c\/strong\u003e is the energy block of the high-voltage Force H3 family. Each 5.12 kWh LFP module is installed in series under the BMS FC1000-FH3 to build HV stacks of 204.8–716.8 V with high efficiency, safety, and seamless integration with high-voltage hybrid inverters via CAN\/RS485\/Modbus RTU. Its floor-standing design with IP55 rating, high density, and guided assembly simplifies commissioning and future expansion.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnergy per module: \u003cstrong\u003e5.12 kWh\u003c\/strong\u003e (≈102.4 V nominal, LiFePO4 chemistry).\u003c\/li\u003e\n  \u003cli\u003eSeries operation with BMS FC1000-FH3: 2–7 modules per string (204.8–716.8 V).\u003c\/li\u003e\n  \u003cli\u003eHigh safety: LiFePO4 with electronic protections and balancing managed by BMS.\u003c\/li\u003e\n  \u003cli\u003eFloor-standing format \u003cstrong\u003eIP55\u003c\/strong\u003e with robust structure and front access.\u003c\/li\u003e\n  \u003cli\u003eComprehensive telemetry (SoC\/SoH, voltages, temperature) via CAN\/RS485.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue scalability\u003c\/strong\u003e: expand energy by adding modules without reworking the system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: high voltage = lower currents and less cable loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety\u003c\/strong\u003e: stable LFP chemistry and active BMS protections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimal maintenance\u003c\/strong\u003e: modular design with updatable firmware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional integration\u003c\/strong\u003e: standard communications that prevent alarms and shutdowns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eResidential and light commercial with HV hybrid inverters: self-consumption, backup for critical loads, time-of-use arbitrage, and peak reduction. Ideal when reliability, future growth, and a tidy technical room are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnergy per module\u003c\/td\u003e\n\u003ctd\u003e5.12 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal module voltage\u003c\/td\u003e\n\u003ctd\u003e≈102.4 V (LFP)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSystem architecture\u003c\/td\u003e\n\u003ctd\u003eSeries of 2–7 modules with \u003cstrong\u003eBMS FC1000-FH3\u003c\/strong\u003e (204.8–716.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTypical usable capacity\u003c\/td\u003e\n\u003ctd\u003e≈95% DoD (controlled by BMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharge\/discharge current\u003c\/td\u003e\n\u003ctd\u003eNominal 50 A; max. short 55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCAN \/ RS485 \/ Modbus RTU (via BMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel\u003c\/td\u003e\n\u003ctd\u003eUp to 6 groups in parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOV\/UV, OC, temperature, short circuit, cell balancing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP55 (Force H3 assembly, protected indoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003eCharge −10…55 °C · Discharge −20…45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eHumidity\/Altitude\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing · \u0026lt;4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLifespan\/cycles\u003c\/td\u003e\n\u003ctd\u003eDesign \u0026gt;15 years · \u0026gt;8000 cycles (25 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003eForce H3 cabinet: module ≈540×350×530 mm · ≈92 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UN38.3, IEC62619, IEC63056, UL1973, UL9540A, VDE-AR-E 2510-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility with \u003cstrong\u003eBMS FC1000-FH3\u003c\/strong\u003e and other FH10050 modules. Integration with HV hybrid inverters via CAN\/RS485 (see official list by model). Accessories: Force H3 rack\/base and interconnection cabling.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ePylontech Lithium Battery Module HV 5.12kWh FH10050 Force H3\u003c\/strong\u003e is the safe, efficient, and scalable foundation for building high-performance HV systems for self-consumption and backup.\u003c\/p\u003e","brand":"Pylontech","offers":[{"title":"Default Title","offer_id":51503161540949,"sku":"PYLOBAT008","price":1461.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/PYLONTECH-FH10050.png?v=1762627114","url":"https:\/\/aurensol.net\/en\/products\/modulo-bateria-litio-hv-pylontech-fh10050-force-h3","provider":"Aurensol","version":"1.0","type":"link"}