{"product_id":"magnetotermico-3p-400v-63a-tongou-tod10-125","title":"3P 400V 63A Circuit Breaker Tongou TOD10-125","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMagnetothermic 3P 400V 63A Tongou TOD10-125\u003c\/strong\u003e is a three-phase load break switch (isolator) designed to operate and isolate 400 V AC circuits with a rated current of 63 A. Its AC-22 utilization category makes it suitable for switching mixed loads (inductive and resistive) with complete reliability, ensuring a defined break and safe isolation before maintenance tasks or as a main line switch.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase 3P with \u003cstrong\u003e63 A\u003c\/strong\u003e rated and \u003cstrong\u003e400 V AC\u003c\/strong\u003e (50\/60 Hz).\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAC-22\u003c\/strong\u003e category for switching mixed loads in service.\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand: 1500 A for 1 s; electro-mechanical life of 10,000 cycles.\u003c\/li\u003e\n  \u003cli\u003eConnection for rigid conductors up to 35 mm²; robust screw terminals.\u003c\/li\u003e\n  \u003cli\u003eMounting on 35 mm symmetrical DIN rail; modular format of 3 units (≈54 mm).\u003c\/li\u003e\n  \u003cli\u003eCompliant with IEC\/EN 60947-3 and GB 14048.3 for load break isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOperational safety with visible break and galvanic isolation of the circuit.\u003c\/li\u003e\n  \u003cli\u003eHigh durability for frequent operations and planned maintenance.\u003c\/li\u003e\n  \u003cli\u003eQuick and clean installation in existing panels thanks to its DIN format.\u003c\/li\u003e\n  \u003cli\u003eWiring flexibility: accepts large cross-sections and reliable tightening.\u003c\/li\u003e\n  \u003cli\u003eVersatile use as a main switch, maintenance switch, or upstream of automatic protections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for three-phase panels in commercial and light industrial settings, pumps, HVAC, machinery, IT racks, and photovoltaic subsystems where reliable 3-pole 63 A isolation is required, prior to fuses or automatic circuit breakers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTongou TOD10-125\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUtilization category\u003c\/td\u003e\n\u003ctd\u003eAC-22\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShort-circuit withstand\u003c\/td\u003e\n\u003ctd\u003e1500 A \/ 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectro-mechanical life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection capacity\u003c\/td\u003e\n\u003ctd\u003eRigid conductor up to 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eScrew \/ pillar with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. dimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 54 mm; height 77–80 mm; depth 70–75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60947-3; GB 14048.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eInstallable in surface-mounted or flush modular enclosures and panels (e.g., Kaedra-type families). Complements residual current devices and automatic circuit breakers, as well as terminals and ferrules for professional wiring.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eMagnetothermic 3P 400V 63A Tongou TOD10-125\u003c\/strong\u003e provides reliable three-phase isolation in a compact format, ideal for operation and safety of 63 A lines.\u003c\/p\u003e","brand":"Tongou","offers":[{"title":"Default Title","offer_id":51503350415701,"sku":"TONGPRO029","price":27.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TONGOU-MAGNETOTERMICO-3P-1_a94c4151-dea7-4396-a67b-9a62ec628f8e.png?v=1762630456","url":"https:\/\/aurensol.net\/en\/products\/magnetotermico-3p-400v-63a-tongou-tod10-125","provider":"Aurensol","version":"1.0","type":"link"}