{"product_id":"magnetotermico-2p-400v-63a-tongou-tod10-125","title":"2P 400V 63A Miniature Circuit Breaker Tongou TOD10-125","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMagnetothermic 2P 400V 63A Tongou TOD10-125\u003c\/strong\u003e is a two-pole load break switch (isolator) for 400 V AC lines. Designed for safe operation and isolation, it allows switching of mixed loads with AC-22 category, providing visible disconnection, long service life, and robust connections for generous cable sections. Its modular DIN rail format facilitates integration as a general bipolar switch or as an isolation point upstream of automatic protections.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2 poles, \u003cstrong\u003e63 A\u003c\/strong\u003e rated, \u003cstrong\u003e400 V AC\u003c\/strong\u003e, 50\/60 Hz.\u003c\/li\u003e\n  \u003cli\u003eUtilization category \u003cstrong\u003eAC-22\u003c\/strong\u003e for switching mixed loads (inductive and resistive).\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand: 1500 A for 1 s; electro-mechanical life: 10,000 operations.\u003c\/li\u003e\n  \u003cli\u003eHigh-pressure screw terminals; accepts rigid conductor up to 35 mm².\u003c\/li\u003e\n  \u003cli\u003eMounting on 35 mm DIN rail; approximate width 36 mm (2 modules) for compact panels.\u003c\/li\u003e\n  \u003cli\u003eCompliance with IEC\/EN 60947-3 and GB 14048.3 for load break isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOperational safety with visible disconnection and galvanic isolation of both poles.\u003c\/li\u003e\n  \u003cli\u003eQuick and tidy installation thanks to its modular DIN format.\u003c\/li\u003e\n  \u003cli\u003eLarge-section connections minimize losses and overheating.\u003c\/li\u003e\n  \u003cli\u003eDurability and reliability in periodic operations (10,000 cycles).\u003c\/li\u003e\n  \u003cli\u003eVersatile use as a general 2P switch or isolator upstream of protections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for single-phase 2P or two-phase 400 V AC panels in residential, commercial, and light industrial settings: subpanels, pumps, HVAC, light machinery, IT\/UPS racks, and photovoltaic systems where reliable bipolar isolation is required before automatic circuit breakers and residual current devices.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTongou TOD10-125\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUtilization category\u003c\/td\u003e\n\u003ctd\u003eAC-22\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShort-time withstand\u003c\/td\u003e\n\u003ctd\u003e1500 A \/ 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectro-mechanical life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection capacity\u003c\/td\u003e\n\u003ctd\u003eRigid up to 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eScrew \/ pillar with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. dimensions\u003c\/td\u003e\n\u003ctd\u003eW. 36 mm; H. 77–80 mm; D. 70–75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60947-3; GB 14048.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eFits standard modular enclosures and panels (e.g., Kaedra-type families). Complements downstream automatic protections (residual current devices and circuit breakers) and professional connection accessories such as ferrules and tubular terminals.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eMagnetothermic 2P 400V 63A Tongou TOD10-125\u003c\/strong\u003e provides reliable, durable, and compact bipolar isolation for modern panels requiring safe operation at 400 V AC.\u003c\/p\u003e","brand":"Tongou","offers":[{"title":"Default Title","offer_id":51503349924181,"sku":"TONGPRO038","price":22.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TONGOU-MAGNETOTERMICO-2P-1_e7caffaa-91f9-40a5-8169-85a76e4d2d4e.png?v=1762630449","url":"https:\/\/aurensol.net\/en\/products\/magnetotermico-2p-400v-63a-tongou-tod10-125","provider":"Aurensol","version":"1.0","type":"link"}