{"product_id":"magnetotermico-2p-400v-125a-tongou-tod10-125","title":"2P 400V 125A Miniature Circuit Breaker Tongou TOD10-125","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMagnetothermic 2P 400V 125A Tongou TOD10-125\u003c\/strong\u003e is a two-pole load break switch capable of handling high currents on 400 V AC lines. Its AC-22 category makes it suitable for switching mixed loads commonly found in real installations (motors with moderate starting, resistors, switched-mode power supplies), providing a defined disconnection and safe circuit isolation. It is designed to function as a main switch, maintenance switch, or as an isolation point before automatic protections.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2 poles with \u003cstrong\u003e125 A\u003c\/strong\u003e rated and \u003cstrong\u003e400 V AC\u003c\/strong\u003e at 50\/60 Hz.\u003c\/li\u003e\n  \u003cli\u003eUtilization category \u003cstrong\u003eAC-22\u003c\/strong\u003e for mixed loads with good switching capacity.\u003c\/li\u003e\n  \u003cli\u003eShort-term thermal withstand: 1500 A\/1 s; electro-mechanical life 10,000 cycles.\u003c\/li\u003e\n  \u003cli\u003eReinforced screw terminals and rigid conductor capacity up to 35 mm².\u003c\/li\u003e\n  \u003cli\u003eModular format for 35 mm DIN rail with a narrow design that saves space.\u003c\/li\u003e\n  \u003cli\u003eConstruction in accordance with IEC\/EN 60947-3 and GB 14048.3 for maximum reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOperational safety: visible disconnection and galvanic isolation of the circuit.\u003c\/li\u003e\n  \u003cli\u003ePrepared for high currents with low voltage drop and robust terminals.\u003c\/li\u003e\n  \u003cli\u003eSimple installation and maintenance; ideal for frequent switching operations.\u003c\/li\u003e\n  \u003cli\u003eVersatile use as a main switch for subpanels or equipment.\u003c\/li\u003e\n  \u003cli\u003eFully compatible with standard market enclosures and DIN rails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for distribution panels in commercial and light industrial settings, pumping systems, HVAC, workshops, UPS\/inverters, and subpanels of photovoltaic systems where high-current bipolar isolation and frequent operation are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTongou TOD10-125\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eAC-22 (mixed loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShort-circuit withstand\u003c\/td\u003e\n\u003ctd\u003e1500 A for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectro-mechanical life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection capacity\u003c\/td\u003e\n\u003ctd\u003eRigid conductor up to 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eScrew\/pillar with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApproximate dimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 36 mm (2 modules), height 77–80 mm, depth 70–75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60947-3; GB 14048.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eSuitable for surface-mounted\/flush-mounted modular enclosures and panels (e.g., Kaedra-type ranges). Complements residual current devices and automatic circuit breakers, as well as professional connection terminals and ferrules.\u003c\/p\u003e\n\u003cp\u003eWith the \u003cstrong\u003eMagnetothermic 2P 400V 125A Tongou TOD10-125\u003c\/strong\u003e you obtain robust and durable bipolar isolation, ideal for safe switching in high-load installations.\u003c\/p\u003e","brand":"Tongou","offers":[{"title":"Default Title","offer_id":51503349465429,"sku":"TONGPRO028","price":22.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TONGOU-MAGNETOTERMICO-2P-1_4a2c6c2d-3607-4e90-916b-d2c66f194182.png?v=1762630446","url":"https:\/\/aurensol.net\/en\/products\/magnetotermico-2p-400v-125a-tongou-tod10-125","provider":"Aurensol","version":"1.0","type":"link"}