{"product_id":"inversor-hibrido-trifasico-azzurro-hyd20000-zss-20kw-hv","title":"Azzurro HYD20000 ZSS Three-Phase Hybrid Inverter 20kW IP65 2 MPPT HV","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAzzurro HYD20000 ZSS 20kW IP65 2 MPPT HV Three-Phase Hybrid Inverter\u003c\/strong\u003e is an “all-in-one” device for three-phase self-consumption that integrates a grid inverter, high-voltage battery charger, and EPS backup. With two MPPT and two HV battery channels, it intelligently manages flows between photovoltaics, storage, and grid to maximize savings, comply with zero-feed-in regulations, and ensure service continuity. Its \u003cstrong\u003eIP65\u003c\/strong\u003e rating, high efficiency (up to 98.2%), and HV platform (200–750 V) make it a robust solution ready for 20 kW commercial and industrial projects.\u003c\/p\u003e\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power 20 kW (22 kVA max.) on three-phase output 3×230\/400 V with active power control 0–100% and reactive management (programmable PF ±0.8).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2 independent MPPT\u003c\/strong\u003e with up to 2 strings per MPPT (4 strings total); MPPT range 180–960 V and full load 450–850 V.\u003c\/li\u003e\n  \u003cli\u003eBattery platform \u003cstrong\u003eHV 200–750 V\u003c\/strong\u003e: two configurable channels (independent or parallel) with up to 20 kW total charge\/discharge.\u003c\/li\u003e\n  \u003cli\u003eThree-phase \u003cstrong\u003e20 kW EPS backup\u003c\/strong\u003e (22 kVA 60 s) with switching \u0026lt; 20 ms to maintain critical loads in case of grid failure.\u003c\/li\u003e\n  \u003cli\u003eOn-board Energy Meter, zero-feed-in function, and parallel-ready option to increase system power.\u003c\/li\u003e\n  \u003cli\u003eLocal and remote monitoring: RS485\/USB\/Bluetooth as standard; optional Wi-Fi\/4G\/Ethernet; CAN 2.0 for HV battery BMS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutonomy and savings\u003c\/strong\u003e: prioritizes PV energy to supply loads and charge batteries; exports only when convenient or permitted.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eService continuity\u003c\/strong\u003e: the three-phase EPS keeps critical lines (lighting, ICT, light pumping, partial HVAC) operational during outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDesign flexibility\u003c\/strong\u003e: two MPPT to optimize roofs with different orientations\/inclinations and two HV channels to adapt power and capacity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient HV platform\u003c\/strong\u003e: higher voltages → lower currents, less loss, and more contained cable sections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal export control\u003c\/strong\u003e: programmable injection limit and compatibility with CT\/external meters for zero-export.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable operation\u003c\/strong\u003e: IP65, integrated DC\/AC protections, diagnostics via app, and detailed logs for efficient O\u0026amp;M.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for three-phase self-consumption 230\/400 V in SMEs, commerce, agri-food, carports, and energy communities requiring HV storage and backup. The \u003cstrong\u003eAzzurro HYD20000 ZSS 20kW IP65 2 MPPT HV Three-phase Hybrid Inverter\u003c\/strong\u003e is especially useful in installations with multiple capture zones (E\/W\/S), with zero-export requirements, and with the need to increase power through parallel operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e20 kW AC (max. 22 kVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e3\/N\/PE 220\/380–230\/400 V · 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eThree-phase hybrid · IP65 · 2 MPPT · 2 HV battery channels\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT \/ strings\u003c\/td\u003e\n\u003ctd\u003e2 \/ up to 2 per MPPT (4 in total)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT window\u003c\/td\u003e\n\u003ctd\u003e180–960 V (full load 450–850 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. DC voltage PV\u003c\/td\u003e\n\u003ctd\u003e1000 V · Vstart 250 V · Vnom 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent per MPPT\u003c\/td\u003e\n\u003ctd\u003e25 A max. (30 A absolute)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eHV Battery\u003c\/td\u003e\n\u003ctd\u003eLi-ion ZCS 200–750 V · 2 channels (independent\/parallel) · 20 kW max. charge\/discharge · 25 A per channel (35 A peak 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThree-phase EPS\u003c\/td\u003e\n\u003ctd\u003e20 kW (22 kVA 60 s) · \u0026lt; 20 ms transfer · 3×230\/400 V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eMax. 98.2% · EU 97.7% · MPPT 99.9% · battery 97.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eAnti-islanding, RCMU, ground fault, overcurrent\/overtemp., DC isolator, SPD T2 on DC\/AC, DC reverse polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eRS485, USB, Bluetooth; opt. Wi-Fi\/4G\/Ethernet · CAN 2.0 for HV BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMeasurement\/IO\u003c\/td\u003e\n\u003ctd\u003eOn-board Energy Meter · RS485 for external meters · 6 digital inputs · CT input\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIP65 · −30…+60 °C (derating \u0026gt; ~45 °C) · \u0026lt; 45 dB · altitude ≤ 4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions \/ Weight\u003c\/td\u003e\n\u003ctd\u003e515 × 571 × 264 mm \/ ≈ 37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with mono, poly, PERC, and bifacial PV modules within Voc\/Isc limits and with ZCS high-voltage batteries (CAN communication). Supports meters\/CT for export control and communication with management platforms via RS485 or Wi-Fi\/4G\/Ethernet modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAzzurro HYD20000 ZSS 20kW IP65 2 MPPT HV Three-phase Hybrid Inverter\u003c\/strong\u003e is a professional solution for three-phase storage and self-consumption projects that require safety, efficiency, and comprehensive energy control.\u003c\/p\u003e\n","brand":"Azzurro","offers":[{"title":"Default Title","offer_id":51502730838357,"sku":"AZZUINV021","price":3071.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/AZZURRO-HYD2000-ZSS.png?v=1762624967","url":"https:\/\/aurensol.net\/en\/products\/inversor-hibrido-trifasico-azzurro-hyd20000-zss-20kw-hv","provider":"Aurensol","version":"1.0","type":"link"}