{"product_id":"interruptor-diferencial-xid-63-4p-40a-30ma-tipo-a","title":"Residual Current Circuit Breaker XID-63 4P 40A 30mA Type A","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eXID-63 4P 40A 30mA Type A Residual Current Circuit Breaker\u003c\/strong\u003e is a 4-pole RCCB (three phases + neutral) designed to protect people and installations against earth leakage currents. With a sensitivity of 30 mA and \u003cstrong\u003eType A\u003c\/strong\u003e technology, it detects alternating and pulsating DC residual currents, making it ideal for lines with electronic loads (inverters, variable speed drives, chargers, rectified power supplies, etc.). Its reliable operation, the operating lever with clear ON\/OFF indication, and the “TEST” button facilitate periodic verification of the device. The unit operates at 400 V~ (50\/60 Hz) and is prepared for quick installation on DIN rail in residential, commercial, or industrial panels.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 poles, 40 A, 30 mA, Type A\u003c\/strong\u003e: effective protection in three-phase networks with neutral.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eService voltage 400 V~ 50\/60 Hz\u003c\/strong\u003e and clear front labeling with electrical diagram.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTEST button\u003c\/strong\u003e with “TEST MONTHLY” indication to verify correct tripping.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN\/IEC 61008-1 standards\u003c\/strong\u003e: safety and performance in accordance with international standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e with quick snap-in and accessible terminals for clean wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConditional short-circuit capacity\u003c\/strong\u003e with SCPD (fuse) as indicated by the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIncreased safety for people: 30 mA sensitivity limits exposure time to dangerous currents.\u003c\/li\u003e\n  \u003cli\u003eCompatibility with electronic loads: \u003cstrong\u003eType A\u003c\/strong\u003e technology detects pulsating DC leakage that a Type AC might not trip on.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: the test button allows checking operation without tools.\u003c\/li\u003e\n  \u003cli\u003eQuick and tidy installation: modular format for DIN rail and clearly identified connections.\u003c\/li\u003e\n  \u003cli\u003eVersatile use: suitable for homes, small businesses, service panels, EV chargers (where applicable), and inverter\/grid panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eResidual current protection in three-phase panels with neutral: homes with three-phase supply, commercial premises, small workshops, charging centers, technical rooms, AC distribution in self-consumption systems, control cabinets, and main or secondary panels where detection of alternating and pulsating leakage is required.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXID-63\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4P (L1–L2–L3–N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated current (In)\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual sensitivity (IΔn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTripping type\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e (AC + pulsating DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage\/frequency\u003c\/td\u003e\n\u003ctd\u003e400 V~; 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1 \/ IEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest\/verification\u003c\/td\u003e\n\u003ctd\u003eTEST button (monthly use recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConditional short-circuit capacity\u003c\/td\u003e\n\u003ctd\u003eWith SCPD (fuse) according to manufacturer’s datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eResidential, commercial, and light industrial panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eInstallable in modular panels and HT series weatherproof boxes (for example: HT-12WAYS, HT-18WAYS, HT-24WAYS), together with C\/D curve circuit breakers, busbar combs, earth\/neutral terminals, and type II AC surge protectors. In charging stations or equipment with electronics, confirm selectivity and, if required by the manufacturer, consider \u003cem\u003eType A-EV\u003c\/em\u003e or \u003cem\u003eType B\u003c\/em\u003e in the protection chain.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eXID-63 4P 40A 30mA Type A Residual Current Circuit Breaker\u003c\/strong\u003e offers reliable and standard-compliant protection for modern three-phase networks, combining personal safety, ease of installation, and preventive maintenance through periodic testing.\u003c\/p\u003e","brand":"WorldSunLight","offers":[{"title":"Default Title","offer_id":51503351988565,"sku":"WORLPRO002","price":6.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/DIFERENCIAL-XID-4P-1.png?v=1762630479","url":"https:\/\/aurensol.net\/en\/products\/interruptor-diferencial-xid-63-4p-40a-30ma-tipo-a","provider":"Aurensol","version":"1.0","type":"link"}