{"product_id":"diferencial-tipo-b-2p-25a-30ma-tongou-tord4b-63","title":"Type B Differential 2P 25A 30mA Tongou TORD4B-63","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Tongou TORD4B-63 Type B RCCB 2P 25A 30mA is designed for single-phase 230–240 V networks that include electric vehicle chargers, AC-connected photovoltaic inverters, and variable speed drives. As a \u003cstrong\u003eType B\u003c\/strong\u003e device, it detects sinusoidal, pulsating, and direct residual currents, providing the highest level of personal and fire protection when power electronics are present. Its modular DIN rail construction, robust electrical characteristics (6 kA conditional, Ui 250 V, Uimp 6 kV), and mechanical\/electrical durability make it the professional choice for residential and commercial distribution boards.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUniversal leakage protection: AC, A (pulsating DC), and smooth DC in accordance with IEC\/EN 62423.\u003c\/li\u003e\n  \u003cli\u003e2P configuration, rated current 25 A and sensitivity 30 mA; voltage 230–240 V, 50 Hz.\u003c\/li\u003e\n  \u003cli\u003eConditional short-circuit capacity: 6 kA; Ui 250 V and Uimp 6 kV.\u003c\/li\u003e\n  \u003cli\u003eIP40\/IP20 ratings, status indication, and toggle actuator.\u003c\/li\u003e\n  \u003cli\u003eService life: 20,000 mechanical operations and 15,000 electrical; tightening torque 2 Nm.\u003c\/li\u003e\n  \u003cli\u003eOperating range: −25 °C to +60 °C; installation height up to 2000 m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eComplies with EV manufacturer requirements and applicable regulations for the presence of residual DC.\u003c\/li\u003e\n  \u003cli\u003eClean and quick installation on DIN rail, with terminals prepared for rigid cable or with ferrule.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety in environments with converters, preventing nuisance tripping and improving service continuity.\u003c\/li\u003e\n  \u003cli\u003eCompact format that optimizes electrical panel space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for domestic and professional charging points, solar self-consumption with AC injection\/disconnection, HVAC, pumps, and processes with variable speed drives. Recommended when class B is required by equipment specification or due to the presence of harmonics and direct current components.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eType B RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles \/ Current\u003c\/td\u003e\n\u003ctd\u003e2P \/ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage \/ Frequency\u003c\/td\u003e\n\u003ctd\u003e230–240 V AC \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConditional capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUi \/ Uimp\u003c\/td\u003e\n\u003ctd\u003e250 V \/ 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 (module) \/ IP20 (terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCable section\u003c\/td\u003e\n\u003ctd\u003eRigid 1–25 mm² | With ferrule 1–16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd\u003e≈85 × 35.7 × 75.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−25 °C…+60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61008-1, IEC\/EN 62423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eUse with charging points (for example, Tesla Wall Connector Gen 3) and with inverters\/AC networks with power electronics. Complement with watertight enclosures and modular panels (Schneider Kaedra), ferrules and copper terminals (Sofamel), and main circuit breakers rated at 25 A. When you provide internal URLs for these accessories, they will be linked here.\u003c\/p\u003e\n\n\u003cp\u003eWith the \u003cstrong\u003eTongou TORD4B-63 Type B RCCB 2P 25A 30mA\u003c\/strong\u003e you get reliable, compact class B residual current protection, ready for EV and self-consumption panels.\u003c\/p\u003e","brand":"Tongou","offers":[{"title":"Default Title","offer_id":51503345697109,"sku":"TONGPRO002","price":68.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TONGOU-TORD4B-63-2P-1_25fe911d-c6d4-4628-ad07-310a36ae0188.png?v=1762630380","url":"https:\/\/aurensol.net\/en\/products\/diferencial-tipo-b-2p-25a-30ma-tongou-tord4b-63","provider":"Aurensol","version":"1.0","type":"link"}