{"product_id":"diferencial-2p-50a-30ma-tipo-a-tongou-tord4-63","title":"Type A Differential 2P 50A 30mA Tongou TORD4-63","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Tipo A 2P 50A 30mA Tongou TORD4-63 Residual Current Device is designed to increase the safety of single-phase installations with high current demand. As a class A residual current circuit breaker (RCCB), it detects sinusoidal residual currents and \u003cstrong\u003epulsating direct current\u003c\/strong\u003e, offering superior protection compared to type AC devices in the presence of domestic power electronics (induction, rectifier power supplies, variable speed drives, etc.). With 2 poles, \u003cstrong\u003e50 A\u003c\/strong\u003e rated current, and \u003cstrong\u003e30 mA\u003c\/strong\u003e sensitivity, it is ideal for kitchen lines, water heaters, air conditioning, and subpanels that require higher capacity while maintaining safety and reliability.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass A: detection of AC and pulsating DC leakage, with test button for periodic verification.\u003c\/li\u003e\n  \u003cli\u003e2P, 50 A, IΔn 30 mA; operating voltage 110–240 V AC; 50\/60 Hz.\u003c\/li\u003e\n  \u003cli\u003eConditional capacity (IΔc) 6 kA and impulse withstand voltage (Uimp) 6 kV.\u003c\/li\u003e\n  \u003cli\u003eModular enclosure IP40 (device) and IP20 (terminals); clip-on mounting on 35 mm DIN rail.\u003c\/li\u003e\n  \u003cli\u003eLarge terminals for high cross-sections: rigid 1–35 mm², flexible\/ferrule 1–25 mm²; torque 2.5 Nm.\u003c\/li\u003e\n  \u003cli\u003eDurability: ≥20,000 electromechanical cycles; use up to 2000 m and −5 °C…+60 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePersonal protection\u003c\/strong\u003e with 30 mA tripping, reducing the risk of electrocution and fire.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e with modern electronic loads that may inject a pulsating DC component.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional installation\u003c\/strong\u003e thanks to its 4-module format (≈71.6 mm) and large-section terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobustness\u003c\/strong\u003e against transients (Uimp 6 kV) and simple selectivity with upstream circuit breakers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy maintenance\u003c\/strong\u003e with clear status indication and integrated functional test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-load single-phase circuits in homes, businesses, and offices: ceramic hobs, ovens, water heaters, air conditioning, general outlets, subpanels, and small technical rooms. If the application may generate \u003cem\u003epure DC\u003c\/em\u003e (some electric vehicle chargers, specific variable speed drives), use a \u003cstrong\u003eType B\u003c\/strong\u003e residual current device as prescribed by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles \/ Current\u003c\/td\u003e\n\u003ctd\u003e2P \/ 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSensitivity (IΔn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage \/ Frequency\u003c\/td\u003e\n\u003ctd\u003e110–240 V AC \/ 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConditional capacity (IΔc)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eImpulse withstand (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCable cross-section\u003c\/td\u003e\n\u003ctd\u003eRigid 1–35 mm² | With ferrule 1–25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e2.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 module \/ IP20 terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e≈71.6 × 85 × 75.1 mm (4 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail · “Toggle” lever\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePermissible environment\u003c\/td\u003e\n\u003ctd\u003e−5 °C…+60 °C · ≤2000 m · pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eComplete the installation with \u003ca href=\"\/en\/products\"\u003ecircuit breakers\u003c\/a\u003e suitable for 50 A, \u003ca href=\"\/en\/products\"\u003eAC surge protection devices\u003c\/a\u003e, watertight enclosures (e.g., Schneider Kaedra), and copper ferrules\/terminals for cross-sections of 16–35 mm².\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eTipo A 2P 50A 30mA Tongou TORD4-63 Residual Current Device\u003c\/strong\u003e combines high capacity, class A detection, and compact format for demanding residential and commercial projects.\u003c\/p\u003e","brand":"Tongou","offers":[{"title":"Default Title","offer_id":51503345074517,"sku":"TONGPRO019","price":32.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TONGOU-TORD4-63_059f6e71-aa05-48bf-99b1-1d0a8a276975.png?v=1762630365","url":"https:\/\/aurensol.net\/en\/products\/diferencial-2p-50a-30ma-tipo-a-tongou-tord4-63","provider":"Aurensol","version":"1.0","type":"link"}