{"product_id":"diferencial-2p-16a-30ma-tipo-a-tongou-tord4-63","title":"Type A Differential 2P 16A 30mA Tongou TORD4-63","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Diferencial Tipo A 2P 16A 30mA Tongou TORD4-63 is a residual current circuit breaker (RCCB) designed for single-phase 230 V distribution that protects against indirect contact and reduces fire risk. Its 30 mA sensitivity and Type A tripping curve ensure detection of \u003cstrong\u003esine wave AC and pulsating DC\u003c\/strong\u003e residual currents, common in modern electronic equipment (rectifier power supplies, induction hobs, domestic variable speed drives, etc.). With 2 poles and 16 A capacity, it is the safe choice for general circuits and residential distribution boards.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eType A: detection of AC and pulsating DC; greater immunity than type AC.\u003c\/li\u003e\n  \u003cli\u003e2P, 16 A, IΔn 30 mA; voltage 110–240 V AC; frequency 50\/60 Hz.\u003c\/li\u003e\n  \u003cli\u003eConditional capacity IΔc 6 kA; Uimp 6 kV to withstand transient overvoltages.\u003c\/li\u003e\n  \u003cli\u003eModular housing with \u003cstrong\u003eIP40 (device) and IP20 (terminals)\u003c\/strong\u003e; clip-on mounting on 35 mm DIN rail.\u003c\/li\u003e\n  \u003cli\u003eTightening torque 2 Nm; sections: rigid 1–25 mm² and with ferrule\/flexible 1–16 mm².\u003c\/li\u003e\n  \u003cli\u003eDurability: ≥20,000 electromechanical cycles; altitude up to 2000 m; −5 °C…+60 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReal safety\u003c\/strong\u003e for people and equipment with appropriate sensitivity (30 mA).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e with electronic loads that generate a pulsating DC component.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple installation\u003c\/strong\u003e: 4-module format (≈71.6 mm) and wide terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliability and long life\u003c\/strong\u003e even in demanding residential environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliance\u003c\/strong\u003e IEC\/EN 61008-1 for audits and professional projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for use in household circuits (sockets, small appliances, lighting, water heater, kitchen, light air conditioning) and secondary panels in offices or shops. For electric vehicle chargers or equipment that may inject continuous residual DC, use Type B or manufacturer-specific solutions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles \/ Current\u003c\/td\u003e\n\u003ctd\u003e2P \/ 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSensitivity (IΔn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage \/ Frequency\u003c\/td\u003e\n\u003ctd\u003e110–240 V AC \/ 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConditional capacity (IΔc)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eImpulse withstand (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCable section\u003c\/td\u003e\n\u003ctd\u003eRigid 1–25 mm² | With ferrule 1–16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 module \/ IP20 terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e≈71.6 × 85 × 75.1 mm (4 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail · “Toggle” lever\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e−5 °C…+60 °C · ≤2000 m altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCombine it with suitable \u003ca href=\"\/en\/products\"\u003eminiature circuit breakers\u003c\/a\u003e, modular watertight enclosures (e.g., Schneider Kaedra), AC surge protection, and ferrules\/terminals for professional wiring. Do not use in applications requiring \u003cem\u003epure DC\u003c\/em\u003e detection.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDiferencial Tipo A 2P 16A 30mA Tongou TORD4-63\u003c\/strong\u003e offers reliable and modern protection for your residential and light commercial circuits.\u003c\/p\u003e","brand":"Tongou","offers":[{"title":"Default Title","offer_id":51503344681301,"sku":"TONGPRO017","price":32.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TONGOU-TORD4-63.png?v=1762630357","url":"https:\/\/aurensol.net\/en\/products\/diferencial-2p-16a-30ma-tipo-a-tongou-tord4-63","provider":"Aurensol","version":"1.0","type":"link"}