{"product_id":"descargador-sobretensiones-sma-dc-spd-kit5-t1t2-core1","title":"DC Surge Arrester SMA DC-SPD-KIT5-T1T2 Core1 Type 1+2","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSMA DC-SPD-KIT5-T1T2\u003c\/strong\u003e is a direct current surge arrester of \u003cstrong\u003eType 1+2\u003c\/strong\u003e (Class I+II), developed specifically for integration in the three-phase inverter \u003cstrong\u003eSMA Sunny Tripower CORE1\u003c\/strong\u003e. This advanced protection kit safeguards against direct and indirect surges, ensuring the safety and continuity of the photovoltaic installation even in areas with a high risk of lightning strikes.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eType 1+2 SPD arrester for DC up to 1100 VDC\u003c\/li\u003e\n  \u003cli\u003eExclusive design for SMA CORE1 STP 50-40\u003c\/li\u003e\n  \u003cli\u003eDirect mounting in the internal space of the inverter\u003c\/li\u003e\n  \u003cli\u003eIntegrated monitoring via the inverter electronics\u003c\/li\u003e\n  \u003cli\u003eTotal protection of PV strings (PV+, PV– and PE)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRobust protection against direct lightning strikes and induced overvoltages\u003c\/li\u003e\n  \u003cli\u003eNo need for external panels or additional wiring\u003c\/li\u003e\n  \u003cli\u003eQuick and safe installation, without modifying the inverter\u003c\/li\u003e\n  \u003cli\u003eSPD status monitoring from the CORE1 platform\u003c\/li\u003e\n  \u003cli\u003eAllows compliance with electrical regulations such as ITC-BT-40 or REBT in risk areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eThis surge arrester is recommended for \u003cstrong\u003ecommercial or industrial\u003c\/strong\u003e photovoltaic installations using the \u003cstrong\u003eSMA CORE1 STP 50-40\u003c\/strong\u003e inverter, especially in areas with a high risk of lightning strikes or sensitive environments. Ideal for projects on flat roofs or solar parks where regulations require Type 1+2 SPD protection on the DC side.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Class\u003c\/td\u003e\n\u003ctd\u003eSPD Type 1+2 (Class I+II)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUse\u003c\/td\u003e\n\u003ctd\u003eProtection on inverter DC inputs (PV+)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of modules\u003c\/td\u003e\n\u003ctd\u003e9 DIN modules (6 PV+, 2 PV–, 1 PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eInternal to the CORE1 inverter (reserved space)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEthernet protection\u003c\/td\u003e\n\u003ctd\u003eNot included (can be added externally)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC protection\u003c\/td\u003e\n\u003ctd\u003eRequires additional kit (AC-SPD-KIT-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003e✅ Internal electronic path of the CORE1 inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd\u003e1100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61643-31, UL 1449 Ed.4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eThis product is compatible with:  \n\u003ca href=\"\/en\/products\/inversor-sma-sunny-tripower-core1-50-41\" title=\"Inversor solar trifásico sma stp50-41 50kw core1\" aria-label=\"Inversor solar trifásico sma stp50-41 50kw core1\"\u003eSMA Sunny Tripower CORE1 STP 50-40\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSMA DC-SPD-KIT5-T1T2\u003c\/strong\u003e is the ultimate protection for the CORE1 inverter. It enhances the safety of your installation against direct lightning strikes, with no installation complications or loss of functionality. Compatible, certified, and designed to last.\u003c\/p\u003e\n\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSMA DC-SPD-KIT5-T1T2\u003c\/strong\u003e is a direct current surge arrester of \u003cstrong\u003eType 1+2\u003c\/strong\u003e (Class I+II), developed specifically for integration in the three-phase inverter \u003cstrong\u003eSMA Sunny Tripower CORE1\u003c\/strong\u003e. This advanced protection kit safeguards against direct and indirect surges, ensuring the safety and continuity of the photovoltaic installation even in areas with a high risk of lightning strikes.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eType 1+2 SPD arrester for DC up to 1100 VDC\u003c\/li\u003e\n  \u003cli\u003eExclusive design for SMA CORE1 STP 50-40\u003c\/li\u003e\n  \u003cli\u003eDirect mounting in the internal space of the inverter\u003c\/li\u003e\n  \u003cli\u003eIntegrated monitoring via the inverter electronics\u003c\/li\u003e\n  \u003cli\u003eTotal protection of PV strings (PV+, PV– and PE)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRobust protection against direct lightning strikes and induced overvoltages\u003c\/li\u003e\n  \u003cli\u003eNo need for external panels or additional wiring\u003c\/li\u003e\n  \u003cli\u003eQuick and safe installation, without modifying the inverter\u003c\/li\u003e\n  \u003cli\u003eSPD status monitoring from the CORE1 platform\u003c\/li\u003e\n  \u003cli\u003eAllows compliance with electrical regulations such as ITC-BT-40 or REBT in risk areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eThis surge arrester is recommended for \u003cstrong\u003ecommercial or industrial\u003c\/strong\u003e photovoltaic installations using the \u003cstrong\u003eSMA CORE1 STP 50-40\u003c\/strong\u003e inverter, especially in areas with a high risk of lightning strikes or sensitive environments. Ideal for projects on flat roofs or solar parks where regulations require Type 1+2 SPD protection on the DC side.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Class\u003c\/td\u003e\n\u003ctd\u003eSPD Type 1+2 (Class I+II)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUse\u003c\/td\u003e\n\u003ctd\u003eProtection on inverter DC inputs (PV+)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of modules\u003c\/td\u003e\n\u003ctd\u003e9 DIN modules (6 PV+, 2 PV–, 1 PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eInternal to the CORE1 inverter (reserved space)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEthernet protection\u003c\/td\u003e\n\u003ctd\u003eNot included (can be added externally)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC protection\u003c\/td\u003e\n\u003ctd\u003eRequires additional kit (AC-SPD-KIT-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003e✅ Internal electronic path of the CORE1 inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd\u003e1100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61643-31, UL 1449 Ed.4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eThis product is compatible with:  \n\u003ca href=\"\/en\/products\/inversor-sma-sunny-tripower-core1-50-41\" title=\"Inversor solar trifásico sma stp50-41 50kw core1\" aria-label=\"Inversor solar trifásico sma stp50-41 50kw core1\"\u003eSMA Sunny Tripower CORE1 STP 50-40\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSMA DC-SPD-KIT5-T1T2\u003c\/strong\u003e is the ultimate protection for the CORE1 inverter. It enhances the safety of your installation against direct lightning strikes, with no installation complications or loss of functionality. Compatible, certified, and designed to last.\u003c\/p\u003e","brand":"SMA","offers":[{"title":"Default Title","offer_id":51503226782037,"sku":"SMAACCE008","price":155.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/SMA-SPD-KIT5.png?v=1762628188","url":"https:\/\/aurensol.net\/en\/products\/descargador-sobretensiones-sma-dc-spd-kit5-t1t2-core1","provider":"Aurensol","version":"1.0","type":"link"}