{"product_id":"descargador-sobretension-600vdc-2p","title":"DC Surge Protector XLSPD-PV 600V 2P","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC Surge Protector XLSPD-PV 600V 2P\u003c\/strong\u003e is a specific protector for the DC side of photovoltaic installations. Designed to divert transient overvoltages to ground caused by grid switching, inverter commutations, or indirect lightning strikes, it safeguards modules, wiring, and power electronics. Its modular architecture for DIN rail and plug-in cartridges with visual indicator allow for quick replacement when the protective element reaches end of life, reducing downtime and maintenance costs.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUc 600 V DC\u003c\/strong\u003e: suitable for panel strings with working voltage up to 600 V in direct current.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2 poles (2P)\u003c\/strong\u003e: typical protection of positive\/negative string against transients to ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 2 (Class II)\u003c\/strong\u003e: effective discharge of temporary and transient overvoltages in PV systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug-in cartridges\u003c\/strong\u003e with end-of-life window: quick maintenance without rewiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e with screw terminals: clean integration in combiner or DC panel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP40\u003c\/strong\u003e on front and self-extinguishing heat-resistant housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProtects critical equipment (modules, inverter, meters, and DC wiring) by limiting overvoltage impulses.\u003c\/li\u003e\n  \u003cli\u003eGreater \u003cstrong\u003eservice continuity\u003c\/strong\u003e and reduction of failures due to electrical surges.\u003c\/li\u003e\n  \u003cli\u003eSimple diagnosis: the \u003cstrong\u003estatus indicator\u003c\/strong\u003e allows you to see at a glance when to replace the cartridge.\u003c\/li\u003e\n  \u003cli\u003eQuick and tidy installation thanks to the DIN format and its compact design.\u003c\/li\u003e\n  \u003cli\u003eSolution aligned with best practices for photovoltaic protection according to low voltage regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eProtection of \u003cstrong\u003ephotovoltaic strings\u003c\/strong\u003e in field panels or combiner boxes, DC inputs of residential and commercial inverters, self-consumption systems, solar pumping, and light industrial applications where it is necessary to limit transients at \u003cstrong\u003e600 V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXLSPD-PV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (positive and negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaximum continuous voltage (Uc)\u003c\/td\u003e\n\u003ctd\u003e600 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Class\u003c\/td\u003e\n\u003ctd\u003eType 2 \/ Class II (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 (front)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCartridges\u003c\/td\u003e\n\u003ctd\u003ePlug-in with end-of-life indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal for rigid or flexible cable with ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUse\u003c\/td\u003e\n\u003ctd\u003ePV strings and DC inverter inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eResidential, commercial, light industrial (DC side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eIntegrates into HT series watertight panels such as the \u003ca href=\"\/en\/products\/cuadro-estanco-ip65-ht-24ways-24-modulos-2-filas\"\u003eHT-24WAYS IP65 24 modules 2 rows\u003c\/a\u003e. Complements standard DC protections such as \u003cstrong\u003e10×38 gPV fuse holders\u003c\/strong\u003e (without link), DC disconnectors, and MC4 connectors. On the AC side, it can be coordinated with residual current devices \u003ca href=\"\/en\/products\/diferencial-xid-63-4p-40a-30ma-tipo-a-400v\"\u003eXID-63 4P Type A 30 mA\u003c\/a\u003e and XL8-63 circuit breakers (according to rating).\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC Surge Protector XLSPD-PV 600V 2P\u003c\/strong\u003e is the essential defense for DC photovoltaic strings: compact, reliable, and with agile maintenance, for durable and safe solar installations.\u003c\/p\u003e","brand":"WorldSunLight","offers":[{"title":"Default Title","offer_id":51503357591893,"sku":"WORLPRO018","price":5.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/SOBRETENSIONES-WORLDSUNLIGH-TIENSOL-600V.png?v=1762630636","url":"https:\/\/aurensol.net\/en\/products\/descargador-sobretension-600vdc-2p","provider":"Aurensol","version":"1.0","type":"link"}