{"product_id":"cargador-victron-centaur-12-30-3","title":"Victron Centaur Charger 12V 30A (3 outputs) 3-stage Charging","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Centaur Charger 12V 30A (3 outputs)\u003c\/strong\u003e is designed for applications where reliability and continuous power are mandatory. Its industrial architecture with protected electronics, active ventilation, and epoxy-painted aluminum housing ensures a long service life in marine or industrial environments. It allows charging three 12 V banks simultaneously with maximum efficiency.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e30 A at 12 V\u003c\/strong\u003e with \u003cstrong\u003e3 fully isolated full-power outputs\u003c\/strong\u003e for service, starter, and auxiliary banks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3-stage charging\u003c\/strong\u003e IUoU (bulk, absorption ~14.3 V, float ~13.5 V) with temperature compensation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal input 90–265 VAC\u003c\/strong\u003e (45–65 Hz) and power factor 1; stable even with generators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFront ammeter\u003c\/strong\u003e for direct monitoring of charging current.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtections\u003c\/strong\u003e against overtemperature (automatic derating) and output short circuit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust IP20 design\u003c\/strong\u003e, stainless steel screws, and coated electronics against salt mist.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBalances and maintains multiple banks without losing current on any output.\u003c\/li\u003e\n  \u003cli\u003eExtends battery life thanks to IUoU management and AGM\/GEL\/lead selection.\u003c\/li\u003e\n  \u003cli\u003eGlobal installation: operates on any grid (90–265 V) and with generator sets.\u003c\/li\u003e\n  \u003cli\u003eSimple monitoring with clear indicators and minimal maintenance.\u003c\/li\u003e\n  \u003cli\u003eReliable operation in extreme climates and ventilated technical spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for recreational or charter boats, camper vans, intervention vehicles, mobile workshops, and 12 V power panels in industry and telecommunications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal charging current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd\u003e3 fully isolated full-power outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharging curve\u003c\/td\u003e\n\u003ctd\u003eIUoU (3 stages): bulk, absorption ~14.3 V, float ~13.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd\u003e-2 mV\/°C per cell (internal sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e90–265 VAC, 45–65 Hz, PF=1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRecommended battery capacity\u003c\/td\u003e\n\u003ctd\u003e120–300 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOvertemperature (derating), output short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVentilation\u003c\/td\u003e\n\u003ctd\u003eForced, controlled by temperature\/current\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP20, “ignition protected”\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery connection\u003c\/td\u003e\n\u003ctd\u003eM6 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd\u003e355×215×110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≈ 3.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 60 °C (derating at ≥50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eAluminum RAL 5012 with coated electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with open lead-acid, AGM, and GEL batteries via internal selector. Recommended accessories: BMV monitor and Battery Alarm module. Features triple output; no external distributors required for three banks.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Centaur Charger 12V 30A (3 outputs)\u003c\/strong\u003e offers power, control, and safety for 12 V systems that require continuous and reliable service.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":51503138603349,"sku":"VICTCAR036","price":389.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CENTAUR-12-30-3.png?v=1762626707","url":"https:\/\/aurensol.net\/en\/products\/cargador-victron-centaur-12-30-3","provider":"Aurensol","version":"1.0","type":"link"}