{"product_id":"caja-protecciones-ac-gave-act-e1c-enphase-trifasico","title":"AC Protection Box Enphase Three-phase GAVE ACT-E1C 20A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEnphase Three-Phase AC Protection Box GAVE ACT-E1C 20A 30mA\u003c\/strong\u003e is a 3F+N connection and safety panel that integrates, in a single Class II enclosure, all the key functions of a three-phase Enphase IQ system: isolation, circuit breaker and residual current protection, overvoltage protection, and the environment for three-phase Q-Relay, IQ Gateway\/Envoy (metered), and current transformers (CT) for production and consumption. Designed to streamline installation and ensure regulatory compliance, it offers a professional and robust finish (IK08) suitable for demanding locations.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3F+N configuration for 1 AC circuit with capacity up to 20 A per phase (≈ 13.9 kVA at 3×400\/230 V).\u003c\/li\u003e\n  \u003cli\u003e4P 20 A circuit breaker, curve C, 6 kA (EN 60898-1) for protection against short circuits and overloads.\u003c\/li\u003e\n  \u003cli\u003e4P Type A 30 mA residual current device with immunity to unwanted tripping, compatible with electronic loads.\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) for grid interface protection.\u003c\/li\u003e\n  \u003cli\u003ePlug \u0026 play preparation for the Enphase ecosystem: Q-Relay 3F, IQ Gateway\/Envoy (Metered), and split-core CT.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure, double insulation Class II, IK08 resistance, and field-ready design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSaves time and reduces errors by concentrating protections, measurement, and communications in a single panel.\u003c\/li\u003e\n  \u003cli\u003eMaximum safety with 30 mA RCD and Type II SPD that reduce risks from indirect contact and overvoltages.\u003c\/li\u003e\n  \u003cli\u003eReady for advanced monitoring, power control, and export limitation via Envoy (metered).\u003c\/li\u003e\n  \u003cli\u003eFacilitates compliance with distributor requirements thanks to the three-phase Q-Relay disconnection.\u003c\/li\u003e\n  \u003cli\u003eClean and maintainable installation: streamlined wiring, accessible terminals, and clear labeling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eOriented towards residential and small commercial (C\u0026I) three-phase self-consumption with Enphase HMT\/MIT microinverters or Enphase three-phase strings in Europe, both in installations with grid export and those requiring export limitation. Also suitable for setups with AC-coupled batteries (e.g., Enphase IQ Battery 5P) where the panel acts as the central point for protection and measurement on the AC side.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eUp to ≈ 13.9 kVA (20 A\/phase at 3×400\/230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (three-phase 3F+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eModular polycarbonate enclosure, Class II, IK08\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMagnetothermal protection\u003c\/td\u003e\n\u003ctd\u003e4P 20 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4P · immunized (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 three-phase AC PV circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 586 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with the Enphase IQ three-phase ecosystem (EU\/INT): HMT\/MIT microinverters, IQ Gateway\/Envoy with metering, Q-Relay 3F, and production\/consumption CTs. Integrable in systems with Enphase IQ Battery 5P in three-phase AC coupling.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEnphase AC Protection Box Three-phase GAVE ACT-E1C 20A 30mA\u003c\/strong\u003e is the professional option for centralizing protection, measurement, and control in Enphase 3F+N installations, improving safety, organization, and efficiency from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502777205077,"sku":"GAVEPRO012","price":959.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-E1C.png?v=1762626044","url":"https:\/\/aurensol.net\/en\/products\/caja-protecciones-ac-gave-act-e1c-enphase-trifasico","provider":"Aurensol","version":"1.0","type":"link"}