{"product_id":"caja-protecciones-ac-gave-acm16sda-3-7kw-16a-30ma","title":"AC Protection Box Single-phase GAVE ACM16SDA 3.7kW 16A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACM16SDA 3.7kW 16A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is a compact panel that integrates all critical safety functions for an AC branch of up to 3.7 kW in a single enclosure. It combines circuit breaker protection, high-sensitivity residual current protection, and transient overvoltage limitation (Type II SPD), offering a professional, clean, and quick-to-install solution for connecting single-phase inverters or microinverters to the main panel of a home or small business.\u003c\/p\u003e\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase 230 V, 1 dedicated AC circuit, continuous capacity up to 16 A (≈ 3.68 kVA\/kW).\u003c\/li\u003e\n  \u003cli\u003e2P 16 A MCB, curve C, breaking capacity 6 kA for protection against overloads and short circuits.\u003c\/li\u003e\n  \u003cli\u003eType A RCD 30 mA, sensitivity for personal protection and immunity against unwanted tripping.\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) to safeguard the grid interface.\u003c\/li\u003e\n  \u003cli\u003eClass II enclosure (double insulation) in polycarbonate, suitable for indoor or protected outdoor use, with DIN rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster installation: “turnkey” panel that centralizes protections and sectioning of the PV\/AC branch.\u003c\/li\u003e\n  \u003cli\u003eAdvanced safety: 30 mA RCD for personal protection and Type II SPD to mitigate grid transients.\u003c\/li\u003e\n  \u003cli\u003eFacilitated regulatory compliance: selection of switchgear and coordination of protections in accordance with best practices.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: front access to switches and terminals, clear labeling, and streamlined wiring.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust design: ideal where space is limited without sacrificing selectivity with the main panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for residential single-phase self-consumption and small commercial applications with inverters up to 3.7 kW, microinverter branches grouped at 16 A, and systems with AC-coupled batteries whose branch does not exceed the nominal current. Acts as a safe interconnection point between generation\/backup and the main panel, both in installations with grid export and in configurations with export limitation.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 3.7 kW (16 A at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e230 V~ 50 Hz (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eClass II modular enclosure (double insulation) with DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMiniature circuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e2P 16 A · curve C · 6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 231 × 238 × 118 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with single-phase inverters up to 3.7 kW and strings of microinverters whose aggregate does not exceed 16 A at 230 V. Integrable with monitoring systems via external CTs and can be coordinated with upstream protections (main circuit breaker, main residual current device, and main SPD) according to the project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGAVE ACM16SDA 3.7kW 16A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is the professional choice for centralizing safety, order, and reliability in the AC branch of your installation, optimizing assembly time and the protection of equipment and people.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502777270613,"sku":"GAVEPRO001","price":146.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACM-SDA.png?v=1762626045","url":"https:\/\/aurensol.net\/en\/products\/caja-protecciones-ac-gave-acm16sda-3-7kw-16a-30ma","provider":"Aurensol","version":"1.0","type":"link"}