{"product_id":"bateria-tab-12v-6-opzs-600-903ah","title":"12V Stationary Battery TAB 6 OPZS 600 | 903Ah","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e12V Stationary Battery TAB 6 OPZS 600 | 903Ah\u003c\/strong\u003e consists of six TAB 6 OPZS 600 cells of 2 V connected in series. The OPzS tubular construction provides excellent retention of active material, low self-discharge, and great stability in float mode, making it a robust solution for solar banks, UPS, and telecom. It is supplied with the necessary \u003cstrong\u003ebridges and screws\u003c\/strong\u003e for interconnection.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBank capacity: C100 ≈ 903 Ah (C10 ≈ 600 Ah at 12 V).\u003c\/li\u003e\n  \u003cli\u003eComposition: 6× TAB 6 OPZS 600 cells (2 V) – tubular positive plate.\u003c\/li\u003e\n  \u003cli\u003eDesign life: up to 20 years at 20 °C in float mode; self-discharge ≈2–3 %\/month.\u003c\/li\u003e\n  \u003cli\u003eTranslucent SAN container with level marks and cap with ceramic filter.\u003c\/li\u003e\n  \u003cli\u003eModular architecture that allows parallel expansions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh autonomy per cell to reduce the total number of banks.\u003c\/li\u003e\n  \u003cli\u003eLow operating cost due to lower water consumption and extended maintenance intervals.\u003c\/li\u003e\n  \u003cli\u003eQuick visual inspection of electrolyte level.\u003c\/li\u003e\n  \u003cli\u003eVoltage stability for critical 24\/7 loads.\u003c\/li\u003e\n  \u003cli\u003eExcellent performance in long discharges typical of photovoltaics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for medium-high capacity off-grid\/hybrid photovoltaic installations, data centers and UPS, telecommunications stations, emergency lighting, and industrial control\/monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eVented lead-acid OPzS (tubular plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBank voltage\u003c\/td\u003e\n\u003ctd\u003e12 V (6×2 V in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003eC100 ≈ 903 Ah | C10 ≈ 600 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesign life\u003c\/td\u003e\n\u003ctd\u003e≈20 years (20 °C, float mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelf-discharge\u003c\/td\u003e\n\u003ctd\u003e≈2–3 %\/month at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-20 °C…+55 °C (optimal 10–30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCell protection type\u003c\/td\u003e\n\u003ctd\u003eIP25\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectrolyte\u003c\/td\u003e\n\u003ctd\u003eH₂SO₄ 1.24 ± 0.01 kg\/l (20 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCell container\u003c\/td\u003e\n\u003ctd\u003eTranslucent SAN; SAN\/ABS lid\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eSealed sliding pole; M10 hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions per cell (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e191×206×536 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight per cell (wet)\u003c\/td\u003e\n\u003ctd\u003e≈45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBank weight\u003c\/td\u003e\n\u003ctd\u003e≈270 kg (6 cells, without rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIntercell bridges and connection hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with DIN racks\/stands for OPzS 2 V, float chargers\/rectifiers, and maintenance and monitoring accessories. Possible parallel connection with identical banks to increase capacity.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e12V Stationary Battery TAB 6 OPZS 600 | 903Ah\u003c\/strong\u003e stands out for its high capacity, reliability, and reduced maintenance, making it ideal for critical mission solar and industrial projects.\u003c\/p\u003e","brand":"TAB","offers":[{"title":"Default Title","offer_id":51503166685525,"sku":"TABBATE048","price":1794.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TAB-OPZS-12V_2ad5d35a-3c47-4a47-93f4-0184bbcbf452.png?v=1762627207","url":"https:\/\/aurensol.net\/en\/products\/bateria-tab-12v-6-opzs-600-903ah","provider":"Aurensol","version":"1.0","type":"link"}