{"title":"Inverters with Charger + MPPT","description":"\u003ch2\u003eWhat is an inverter with charger + MPPT?\u003c\/h2\u003e\n\u003cp\u003eAn \u003cstrong\u003einverter with charger + MPPT\u003c\/strong\u003e combines three key functions in a single chassis: it converts DC→AC (230 V), \u003cstrong\u003erecharges batteries\u003c\/strong\u003e from the grid or generator through a multi-stage charger, and \u003cstrong\u003emanages the photovoltaic input\u003c\/strong\u003e via an integrated \u003cstrong\u003eMPPT solar charge controller\u003c\/strong\u003e. This approach reduces external components, simplifies wiring, and improves system reliability.\u003c\/p\u003e\n\n\u003ch3\u003eMain advantages\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCleaner installation\u003c\/strong\u003e: fewer devices, fewer connections, and lower probability of errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive management\u003c\/strong\u003e: prioritization of sources (PV, grid\/generator, battery) and fast switching (depending on model).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: the integrated MPPT optimizes the output of the \u003ca href=\"\/en\/collections\/paneles-solares\"\u003epanels\u003c\/a\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpace saving\u003c\/strong\u003e and better organization in the technical room, camper, or engine room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWho is this solution for?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHomes in \u003ca href=\"\/en\/collections\/energia-solar-aislada\"\u003eoff-grid\u003c\/a\u003e setups seeking an \u003cstrong\u003eall-in-one\u003c\/strong\u003e with generator backup.\u003c\/li\u003e\n  \u003cli\u003eCaravans and campers where space and simplicity are critical.\u003c\/li\u003e\n  \u003cli\u003eRecreational boating with the need for stable AC and charging from shore\/generator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey selection criteria\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInverter power\u003c\/strong\u003e (kW): size according to simultaneous loads and peaks (motors\/compressors).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPPT range\u003c\/strong\u003e: PV voltage (Voc\/Vmp) and input current suitable for the panel string.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC charger\u003c\/strong\u003e: charging current (A) appropriate for the \u003ca href=\"\/en\/collections\/baterias\"\u003ebattery\u003c\/a\u003e bank and desired recharge times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e: profiles for AGM, GEL, OPzS and, if applicable, communication with \u003ca href=\"\/en\/collections\/baterias-litio\"\u003elithium\u003c\/a\u003e (CAN\/RS485).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunications\u003c\/strong\u003e and monitoring: RS485\/CAN, Wi-Fi\/Bluetooth, and manufacturer portal\/app.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtections\u003c\/strong\u003e: DC\/AC, SPD, low\/high voltage, overtemperature; \u003cstrong\u003eIP rating\u003c\/strong\u003e according to location.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGeneral specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eSine wave inverter + AC charger + MPPT controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input\u003c\/td\u003e\n\u003ctd\u003eIntegrated MPPT (Vmp\/Voc range and current according to model)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12\/24\/48 V depending on version; AGM\/GEL\/OPzS\/Lithium*\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC output\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eSource priority, generator relay, monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:0.9em\"\u003e\u003cem\u003e* Check compatibility and, for lithium, if communication with BMS is required.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eInstallation best practices\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProtect the battery–equipment section with a \u003cstrong\u003eDC fuse\u003c\/strong\u003e and \u003cstrong\u003edisconnect switch\u003c\/strong\u003e close to the battery.\u003c\/li\u003e\n  \u003cli\u003eSize cable sections to keep \u003cstrong\u003evoltage drop \u0026lt;3%\u003c\/strong\u003e in DC; use \u003cstrong\u003ebusbars\u003c\/strong\u003e for distribution.\u003c\/li\u003e\n  \u003cli\u003eAdjust \u003cstrong\u003echarge\/discharge thresholds\u003c\/strong\u003e and the corresponding battery profile.\u003c\/li\u003e\n  \u003cli\u003eFor PV, respect \u003cstrong\u003eVoc\u003c\/strong\u003e limits at minimum temperature and current per MPPT input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf you are looking for a compact solution that combines \u003cstrong\u003einverter, charger, and MPPT\u003c\/strong\u003e in a single device, this category offers the best balance between \u003cstrong\u003esimplicity\u003c\/strong\u003e, \u003cstrong\u003eperformance\u003c\/strong\u003e, and \u003cstrong\u003ereliability\u003c\/strong\u003e. For variants by voltage or alternative configurations, see \u003ca href=\"\/en\/collections\/inversores-aislada-cargador-12v\"\u003ewith charger 12V\u003c\/a\u003e, \u003ca href=\"\/en\/collections\/inversores-aislada-cargador-24v\"\u003e24V\u003c\/a\u003e, \u003ca href=\"\/en\/collections\/inversores-aislada-cargador-48v\"\u003e48V\u003c\/a\u003e, and \u003ca href=\"\/en\/collections\/inversores-aislada-mppt\"\u003ewith MPPT\u003c\/a\u003e.\u003c\/p\u003e\n","products":[{"product_id":"inversor-cargador-tbb-riio-sun-ii-1kw-12v","title":"TBB Riio Sun II Inverter Charger 1 kW 12V 1KVA-L MPPT 150V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 1 kW 12 V 1KVA-L MPPT 150 V Inverter Charger\u003c\/strong\u003e is an all-in-one off-grid device that integrates a pure sine wave inverter, \u003cstrong\u003eMPPT 150 V\/60 A\u003c\/strong\u003e solar charge controller, and \u003cstrong\u003e40 A\u003c\/strong\u003e AC charger. Designed to maximize the performance of 12 V systems, it combines high efficiency, advanced protections, and BMS communication for safe operation with AGM, GEL, or LiFePO₄ batteries. Its compact architecture simplifies wiring, reduces costs, and accelerates commissioning for residential, light commercial, and backup installations.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous power: \u003cstrong\u003e1 kW (1 kVA)\u003c\/strong\u003e at 230 V AC, pure sine wave.\u003c\/li\u003e\n\u003cli\u003eIntegrated solar controller: \u003cstrong\u003eMPPT 150 V \/ 60 A\u003c\/strong\u003e with wide PV range for series strings.\u003c\/li\u003e\n\u003cli\u003eGrid or generator charger: \u003cstrong\u003e40 A\u003c\/strong\u003e with programmable charging stages for lead-acid and lithium.\u003c\/li\u003e\n\u003cli\u003eSystem battery: \u003cstrong\u003e12 V\u003c\/strong\u003e, compatible with AGM\/GEL\/FLA and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e with dedicated profiles.\u003c\/li\u003e\n\u003cli\u003eIntelligent management: solar\/grid priority, equalization (lead-acid), dry contact relay, and \u003cstrong\u003eRS485\u003c\/strong\u003e for monitoring.\u003c\/li\u003e\n\u003cli\u003eComprehensive protections: over\/under voltage, overload, temperature, short circuit, reverse PV polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum solar utilization\u003c\/strong\u003e thanks to the MPPT 150 V, which allows higher input voltage and reduces losses over long distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower system cost\u003c\/strong\u003e by integrating inverter, AC charger, and controller in a single chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety and lifespan\u003c\/strong\u003e: appropriate charging profiles and BMS communication protect the batteries, especially lithium types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational flexibility\u003c\/strong\u003e: selection of priorities (solar, batteries, or grid) and the possibility of use with a generator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick installation\u003c\/strong\u003e: accessible terminals, intuitive menu, and compact format for small panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for 12 V off-grid homes, field cabins, telecommunications, camper\/marine (at 230 V), domestic backup systems, and small critical loads. Also useful for light pumping with battery and in projects with auxiliary generator.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e1 kW (1 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 150 V \/ 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e40 A (multi-stage, lead-acid and lithium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, dry contact relay; BMS ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging curve\u003c\/td\u003e\n\u003ctd\u003eAbsorption\/Float; equalization for lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, short circuit, thermal, PV\/reverse, battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temp. range\u003c\/td\u003e\n\u003ctd\u003eSuitable for domestic\/light industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIndoor use (ventilated enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003eCompact all-in-one format (approx. 1 kVA class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 12 V AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e batteries with BMS. Supports PV strings as long as the \u003cstrong\u003etotal Voc ≤ 150 V\u003c\/strong\u003e and input currents and recommended cable section are respected. Can be integrated with backup generators and DC\/AC protection panels, fuses, disconnectors, and solar cabling.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 1 kW 12 V 1KVA-L MPPT 150 V Inverter Charger\u003c\/strong\u003e is the compact and professional option to start or upgrade a reliable and efficient off-grid system.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241232725,"sku":"TBBINVE001","price":453.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2.png?v=1762628528"},{"product_id":"inversor-cargador-tbb-riio-sun-ii-1-5kw-24v","title":"TBB Riio Sun II Inverter Charger 1.5 kW 24V 1.5KVA-M MPPT 150V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 1.5 kW 24 V 1.5KVA-M MPPT 150 V Inverter Charger\u003c\/strong\u003e is a state-of-the-art device for 24 V solar systems that combines a 1.5 kW pure sine wave inverter, \u003cstrong\u003eMPPT 150 V\/60 A\u003c\/strong\u003e solar charge controller, and a grid\/generator charger of \u003cstrong\u003e35 A\u003c\/strong\u003e. It provides comprehensive energy management with configurable priority modes, charging profiles for lead-acid and lithium, and RS485 communication for advanced monitoring, offering maximum reliability and performance in off-grid self-consumption and backup solutions.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous power: \u003cstrong\u003e1.5 kW (1.5 kVA)\u003c\/strong\u003e at 230 V AC, pure sine wave.\u003c\/li\u003e\n\u003cli\u003eIntegrated photovoltaic controller: \u003cstrong\u003eMPPT 150 V \/ 60 A\u003c\/strong\u003e for high input voltage series strings.\u003c\/li\u003e\n\u003cli\u003eAC charger: \u003cstrong\u003e35 A\u003c\/strong\u003e with programmable profiles (AGM, GEL, FLA, and LiFePO₄).\u003c\/li\u003e\n\u003cli\u003eBattery system: \u003cstrong\u003e24 V\u003c\/strong\u003e with BMS compatibility and adjustable parameters.\u003c\/li\u003e\n\u003cli\u003eIntelligent management: priority modes, dry contact relay, \u003cstrong\u003eRS485\u003c\/strong\u003e, and remote alarm options.\u003c\/li\u003e\n\u003cli\u003eProtections: over\/under voltage, overload, short circuit, thermal, and PV polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMore usable energy\u003c\/strong\u003e by operating the photovoltaic array at higher voltage with the MPPT 150 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery protection\u003c\/strong\u003e thanks to appropriate charging curves and BMS compatibility for lithium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplified system\u003c\/strong\u003e: fewer devices, fewer failure points, and reduced installation time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e: operates with grid or generator to ensure service continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring and control\u003c\/strong\u003e via RS485 and dry contact relay for automation and notifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for off-grid 24 V homes and businesses, shelters, mobile offices, telecommunications, workshops, and backup systems for critical loads. An excellent option for upgrading existing installations from PWM to high-voltage MPPT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e1.5 kW (1.5 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 150 V \/ 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e35 A (multi-stage, lead and lithium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, dry contact; BMS integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eSolar\/Battery\/Grid priority; generator compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, undervoltage, overload, thermal, PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIndoor use (ventilated enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003eCompact all-in-one format (class 1.5 kVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003e24 V\u003c\/strong\u003e AGM, GEL, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e battery banks with BMS. PV array in series as long as the \u003cstrong\u003etotal Voc ≤ 150 V\u003c\/strong\u003e. Direct integration with generator and \u003cem\u003eDC\/AC protection panels\u003c\/em\u003e, fuses, disconnectors, and solar cabling suitable for 60 A charging current.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 1.5 kW 24 V 1.5KVA-M MPPT 150 V Inverter Charger\u003c\/strong\u003e offers an excellent balance between power, efficiency, and ease of installation for demanding off-grid projects.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241331029,"sku":"TBBINVE002","price":479.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_15452ffd-2d10-453e-889b-6c23380fbe0a.png?v=1762628534"},{"product_id":"inversor-solar-tbb-riio-sun-ii-2kw-24v","title":"TBB Riio Sun II 2 kW 24V 2KVA-M Inverter Charger MPPT 150V 80A","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 2 kW 24 V 2KVA-M MPPT 150 V 80 A Inverter Charger\u003c\/strong\u003e integrates a pure sine wave inverter, 150 V\/80 A MPPT solar charge controller, and 40 A grid\/generator charger in a single unit. Designed for 24 V installations that demand performance and reliability, it reduces installation time and simplifies the electrical panel by concentrating conversion, charging, and energy management functions with comprehensive protections and communications for monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous power: \u003cstrong\u003e2 kW (2 kVA)\u003c\/strong\u003e at 230 V AC, pure sine wave.\u003c\/li\u003e\n  \u003cli\u003ePhotovoltaic controller: \u003cstrong\u003eMPPT 150 V \/ 80 A\u003c\/strong\u003e for series strings with lower voltage drop.\u003c\/li\u003e\n  \u003cli\u003eAC charger: \u003cstrong\u003e40 A\u003c\/strong\u003e multi-stage, programmable for lead-acid and LiFePO₄.\u003c\/li\u003e\n  \u003cli\u003eBattery system: \u003cstrong\u003e24 V\u003c\/strong\u003e with dedicated profiles and BMS compatibility.\u003c\/li\u003e\n  \u003cli\u003eAdvanced management: Solar\/Battery\/Grid priorities, dry relay, and \u003cstrong\u003eRS485\u003c\/strong\u003e communication.\u003c\/li\u003e\n  \u003cli\u003eIntegrated protections: overload, short circuit, over\/under voltage, and temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMore solar energy\u003c\/strong\u003e thanks to the high current MPPT (80 A) and 150 V input.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFewer components\u003c\/strong\u003e: inverter, controller, and charger in one chassis, saving space and wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery care\u003c\/strong\u003e with optimized charging curves and lithium (BMS) compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eService continuity\u003c\/strong\u003e: operates with grid or generator when solar irradiation is low.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e and alarms via RS485 and dry contact for automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHomes and businesses in off-grid 24 V, shelters, mobile offices, telecommunications, and backup systems where 2 kW continuous and an 80 A MPPT are required for medium-sized PV arrays with series strings.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e2 kW (2 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 150 V \/ 80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e40 A (multi-stage, lead and lithium)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, dry relay; BMS compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating modes\u003c\/td\u003e\n\u003ctd\u003eSolar \/ Battery \/ Grid-Generator priority\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, thermal, reverse PV, over\/under voltage, short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use, ventilated enclosure, compact all-in-one format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 24 V AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e batteries with BMS. Photovoltaic array in series as long as the \u003cstrong\u003etotal Voc ≤ 150 V\u003c\/strong\u003e and the current does not exceed the MPPT's allowable (80 A). Integrable with generators, \u003cem\u003eDC\/AC protection\u003c\/em\u003e panels, fuses, disconnectors, and solar cabling sized for 80 A operation.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 2 kW 24 V 2KVA-M MPPT 150 V 80 A Inverter Charger\u003c\/strong\u003e provides power, control, and safety in 24 V projects seeking efficiency and ease of installation.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241462101,"sku":"TBBINVE003","price":536.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_8fbffa1e-6a56-493b-a025-447eba9dae65.png?v=1762628539"},{"product_id":"inversor-cargador-tbb-riio-sun-ii-2kw-48v","title":"TBB Riio Sun II Inverter Charger 2 kW 48V 2KVA-S MPPT 250V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 2 kW 48 V 2KVA-S MPPT 250 V Inverter Charger\u003c\/strong\u003e integrates in a single device a 2 kW pure sine wave inverter, \u003cstrong\u003eMPPT 250 V\/60 A\u003c\/strong\u003e solar charge controller, and \u003cstrong\u003e20 A\u003c\/strong\u003e grid\/generator charger. Designed for 48 V battery banks, it simplifies the electrical panel, improves photovoltaic utilization, and provides advanced energy management with comprehensive protections and communication for professional monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous power: \u003cstrong\u003e2 kW (2 kVA)\u003c\/strong\u003e at 230 V AC, pure sine wave.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PV controller: \u003cstrong\u003eMPPT 250 V \/ 60 A\u003c\/strong\u003e for higher voltage series strings.\u003c\/li\u003e\n  \u003cli\u003eMulti-stage AC charger: \u003cstrong\u003e20 A\u003c\/strong\u003e with profiles for lead-acid and LiFePO₄.\u003c\/li\u003e\n  \u003cli\u003eBattery system: \u003cstrong\u003e48 V\u003c\/strong\u003e, compatible with AGM\/GEL\/FLA and lithium (BMS).\u003c\/li\u003e\n  \u003cli\u003eIntelligent management: Solar\/Battery\/Grid priorities, dry contact relay, and \u003cstrong\u003eRS485\u003c\/strong\u003e port.\u003c\/li\u003e\n  \u003cli\u003eProtections: over\/under voltage, overload, short circuit, temperature, and PV polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher solar performance\u003c\/strong\u003e thanks to the 250 V MPPT, which reduces wiring losses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact system\u003c\/strong\u003e: fewer devices and fewer points of failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized battery life\u003c\/strong\u003e with suitable charging curves and BMS compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible operation\u003c\/strong\u003e with grid or generator when irradiation is low.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e and automation via RS485 and dry contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHomes and businesses in 48 V off-grid, remote offices, telecommunications, and backup solutions where 2 kW continuous and a 60 A MPPT with high input voltage are required.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e2 kW (2 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePhotovoltaic controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 250 V \/ 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e20 A (multi-stage, lead and lithium)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 and dry relay; BMS compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eSolar \/ Battery \/ Grid-Generator priority\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, thermal, PV reverse, over\/under voltage, short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use, ventilated enclosure, all-in-one format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003e48 V\u003c\/strong\u003e AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e banks with BMS. Photovoltaic array in series respecting \u003cstrong\u003eVoc ≤ 250 V\u003c\/strong\u003e and the admissible current of the MPPT (60 A). Easily integrates DC\/AC \u003cem\u003eprotection panels\u003c\/em\u003e, fuses\/disconnectors, and auxiliary generators.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 2 kW 48 V 2KVA-S MPPT 250 V Inverter Charger\u003c\/strong\u003e offers efficiency, safety, and professional control in 48 V off-grid systems.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241593173,"sku":"TBBINVE005","price":523.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_642bce32-5f31-4c8d-aaec-26c011521c2c.png?v=1762628546"},{"product_id":"inversor-solar-tbb-riio-sun-ii-3kw-24v","title":"TBB Riio Sun II Inverter Charger 3 kW 24V 3KVA-M MPPT 150V 80A","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 3 kW 24 V 3KVA-M MPPT 150 V 80 A Inverter Charger\u003c\/strong\u003e is the natural evolution for 24 V installations that require more continuous power without sacrificing a compact system. It integrates a 3 kW pure sine wave inverter, a \u003cstrong\u003eMPPT 150 V\/80 A\u003c\/strong\u003e solar charge controller capable of managing larger PV arrays, and a \u003cstrong\u003e70 A\u003c\/strong\u003e grid\/generator charger for rapid battery recovery. With configurable priority modes, professional-level communications and protections, it ensures stable performance in off-grid self-consumption and demanding backup solutions.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous power: \u003cstrong\u003e3 kW (3 kVA)\u003c\/strong\u003e at 230 V AC, high-quality pure sine wave.\u003c\/li\u003e\n  \u003cli\u003eIntegrated solar controller: \u003cstrong\u003eMPPT 150 V \/ 80 A\u003c\/strong\u003e for series strings and reduced cable cross-section.\u003c\/li\u003e\n  \u003cli\u003eHigh-flow AC charger: \u003cstrong\u003e70 A\u003c\/strong\u003e with programmable profiles for lead-acid and lithium.\u003c\/li\u003e\n  \u003cli\u003eSystem batteries: \u003cstrong\u003e24 V\u003c\/strong\u003e, compatible with AGM\/GEL\/FLA and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e with BMS.\u003c\/li\u003e\n  \u003cli\u003eManagement and control: Solar\/Grid\/Battery priorities, dry contact relay, and \u003cstrong\u003eRS485\u003c\/strong\u003e port for monitoring.\u003c\/li\u003e\n  \u003cli\u003eProtections: overload, short circuit, temperature, PV reverse polarity, battery and AC over\/undervoltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreater load capacity\u003c\/strong\u003e with 3 kW continuous for appliances and critical loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e80 A MPPT\u003c\/strong\u003e that maximizes PV field performance and supports more photovoltaic peak power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFast recharge\u003c\/strong\u003e from grid or generator thanks to the 70 A AC charger.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized installation\u003c\/strong\u003e: fewer devices, less wiring, and a cleaner panel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLong battery life\u003c\/strong\u003e due to appropriate charging curves and compatibility with BMS in lithium.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIsolated homes with higher consumption, small businesses, workshops, remote offices, and telecommunications that require 3 kW continuous and an 80 A controller. Also excellent as a \u003cem\u003ebackup\u003c\/em\u003e solution with generator.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e3 kW (3 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 150 V \/ 80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e70 A (multi-stage, lead-acid and lithium)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, dry contact; integration with BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eSolar \/ Battery \/ Grid-Generator priority\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, thermal, PV reverse, over\/undervoltage, short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use, ventilated enclosure, compact all-in-one format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003e24 V\u003c\/strong\u003e AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e banks with BMS. Supports PV strings in series respecting \u003cstrong\u003eVoc ≤ 150 V\u003c\/strong\u003e and sizing wiring and protections to the MPPT current (80 A). Direct integration with generators and \u003cem\u003eDC\/AC protection\u003c\/em\u003e panels, NH\/MCB fuses, disconnectors, and SPD.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 3 kW 24 V 3KVA-M MPPT 150 V 80 A Inverter Charger\u003c\/strong\u003e offers power, versatility, and accelerated recharging for 24 V installations that demand greater capacity without complicating the installation.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241658709,"sku":"TBBINVE004","price":593.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_3bd98ae0-7bbd-47e4-b542-18ed83758a63.png?v=1762628550"},{"product_id":"inversor-solar-tbb-riio-sun-ii-3kw-48v","title":"TBB Riio Sun II Inverter Charger 3 kW 48V 3KVA-S MPPT 250V 60A","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eInverter Charger TBB Riio Sun II 3 kW 48 V 3KVA-S MPPT 250 V 60 A\u003c\/strong\u003e combines a 3 kW pure sine wave inverter with a \u003cstrong\u003eMPPT 250 V\/60 A\u003c\/strong\u003e solar charge controller and a grid\/generator charger of \u003cstrong\u003e35 A\u003c\/strong\u003e. Designed for 48 V battery banks, it provides higher continuous power, excellent utilization of the PV array due to high input voltage, and advanced energy management with professional-grade protections and communications.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous power: \u003cstrong\u003e3 kW (3 kVA)\u003c\/strong\u003e at 230 V AC, pure sine wave.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PV controller: \u003cstrong\u003eMPPT 250 V \/ 60 A\u003c\/strong\u003e suitable for long series strings.\u003c\/li\u003e\n  \u003cli\u003eAC charger: \u003cstrong\u003e35 A\u003c\/strong\u003e with programmable profiles for lead-acid and LiFePO₄.\u003c\/li\u003e\n  \u003cli\u003eBattery system: \u003cstrong\u003e48 V\u003c\/strong\u003e with BMS compatibility.\u003c\/li\u003e\n  \u003cli\u003eIntelligent control: Solar\/Grid\/Battery priorities, dry contact relay, and \u003cstrong\u003eRS485\u003c\/strong\u003e port.\u003c\/li\u003e\n  \u003cli\u003eProtections: overload, short circuit, thermal, over\/undervoltage, and PV polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreater capacity\u003c\/strong\u003e for critical loads with 3 kW continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPPT 250 V\u003c\/strong\u003e reduces cable size and losses, maximizing production.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStable recharging\u003c\/strong\u003e from grid or generator with 35 A to maintain autonomy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified installation\u003c\/strong\u003e by integrating inverter, charger, and controller in a single chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery protection\u003c\/strong\u003e and longer service life thanks to charging profiles and BMS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eOff-grid homes with medium-high consumption, small businesses, workshops, telecommunications, and 48 V backup systems requiring 3 kW continuous and a 60 A MPPT with high input voltage.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e3 kW (3 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePhotovoltaic controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 250 V \/ 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e35 A (multi-stage, lead and lithium)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 and dry contact relay; integration with BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eSolar \/ Battery \/ Grid-Generator priority\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, thermal, PV reverse, over\/undervoltage, short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use, ventilated enclosure, all-in-one format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003e48 V\u003c\/strong\u003e AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e battery banks with BMS. PV array in series respecting \u003cstrong\u003eVoc ≤ 250 V\u003c\/strong\u003e and the maximum current of the MPPT (60 A). Integrates generators and \u003cem\u003eDC\/AC protections\u003c\/em\u003e panels, fuses, disconnectors, and SPD.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eInverter Charger TBB Riio Sun II 3 kW 48 V 3KVA-S MPPT 250 V 60 A\u003c\/strong\u003e provides power, control, and efficiency for 48 V off-grid projects with higher demands.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241789781,"sku":"TBBINVE006","price":611.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_c9cc9c64-e510-462e-b4bf-7977a1dca52c.png?v=1762628555"},{"product_id":"inversor-solar-tbb-riio-sun-ii-5kw-48v","title":"TBB Riio Sun II 5 kW 48V 5KVA-S Inverter Charger MPPT 250V 100A","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 5 kW 48 V 5KVA-S MPPT 250 V 100 A Inverter Charger\u003c\/strong\u003e integrates a pure sine wave inverter, high-capacity solar charge controller, and powerful AC charger into a single unit. Designed for 48 V battery banks, it allows management of larger photovoltaic arrays with two \u003cstrong\u003eMPPT 250 V\u003c\/strong\u003e trackers providing up to \u003cstrong\u003e100 A\u003c\/strong\u003e of charging current, optimizing performance and reducing wiring losses. The \u003cstrong\u003e70 A\u003c\/strong\u003e grid\/generator charger accelerates battery recovery in adverse weather or during consumption peaks. With intelligent management, advanced communications, and protections, it is a robust solution for off-grid self-consumption, microgrids, and professional \u003cem\u003ebackup\u003c\/em\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous power: \u003cstrong\u003e5 kW (5 kVA)\u003c\/strong\u003e at 230 V AC, stable pure sine wave.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2 independent MPPT\u003c\/strong\u003e: \u003cstrong\u003e250 V \/ 100 A\u003c\/strong\u003e total for series strings and improved PV design.\u003c\/li\u003e\n  \u003cli\u003eIntegrated AC charger: \u003cstrong\u003e70 A\u003c\/strong\u003e multi-stage, profiles for lead-acid and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eBattery system: \u003cstrong\u003e48 V\u003c\/strong\u003e, adjustable parameters and BMS compatibility.\u003c\/li\u003e\n  \u003cli\u003eCommunications: \u003cstrong\u003eRS485\u003c\/strong\u003e, dry contact relay, and Solar\/Battery\/Grid priority control.\u003c\/li\u003e\n  \u003cli\u003eProtections: overload, short circuit, thermal, PV reverse, DC and AC over\/undervoltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior performance\u003c\/strong\u003e thanks to two MPPTs that maximize production on roofs with different orientations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower installation cost\u003c\/strong\u003e: high PV voltage (250 V) allows for smaller cable sections and less loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAssured autonomy\u003c\/strong\u003e with 70 A AC charger for fast recharging from grid or generator.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery lifespan\u003c\/strong\u003e protected by optimized charging curves and lithium BMS compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive management\u003c\/strong\u003e and monitoring via RS485 for reliable and traceable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHigh-consumption off-grid homes, businesses and workshops, telecommunications, installations with auxiliary generator, and 48 V backup systems requiring continuous 5 kW, high solar charging current, and reduced recovery times.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e5 kW (5 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBank voltage\u003c\/td\u003e\n\u003ctd\u003e48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT trackers\u003c\/td\u003e\n\u003ctd\u003e2 × MPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT current\u003c\/td\u003e\n\u003ctd\u003eUp to 100 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e70 A (multi-stage, lead-acid and LiFePO₄)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating modes\u003c\/td\u003e\n\u003ctd\u003eSolar \/ Battery \/ Grid-Generator priority\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, thermal, PV reverse, over\/undervoltage, short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use, all-in-one chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003e48 V\u003c\/strong\u003e AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e banks with BMS. Supports PV strings in series respecting \u003cstrong\u003eVoc ≤ 250 V\u003c\/strong\u003e and the total regulator current (100 A). Integrates generators, \u003cem\u003eDC\/AC protection\u003c\/em\u003e panels, fuses, disconnectors, and SPD.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 5 kW 48 V 5KVA-S Inverter Charger\u003c\/strong\u003e offers power, fast recharging, and professional control for high-performance off-grid projects.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241888085,"sku":"TBBINVE007","price":1062.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_561ab5c5-da07-405d-a4cb-5442e42e2e34.png?v=1762628559"},{"product_id":"inversor-solar-tbb-riio-sun-ii-8kw-48v","title":"TBB Riio Sun II 8 kW 48V 8KVA-S Inverter Charger MPPT 250V 100A","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 8 kW 48 V 8KVA-S MPPT 250 V 100 A Inverter Charger\u003c\/strong\u003e is the highest power option in the Riio Sun II family at 48 V. It features a pure sine wave inverter of \u003cstrong\u003e8 kW\u003c\/strong\u003e, two \u003cstrong\u003eMPPT 250 V\u003c\/strong\u003e trackers with up to \u003cstrong\u003e100 A\u003c\/strong\u003e total current, and a \u003cstrong\u003e90 A\u003c\/strong\u003e AC charger for very fast recharging from grid or generator. It is designed for demanding applications where high continuous loads, large photovoltaic arrays, and robust operation with lithium or lead-acid batteries are required, maintaining a clean installation by integrating inverter, regulator, and charger into a single chassis.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous power: \u003cstrong\u003e8 kW (8 kVA)\u003c\/strong\u003e at 230 V AC, pure sine wave.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2 independent MPPT\u003c\/strong\u003e: \u003cstrong\u003e250 V \/ 100 A\u003c\/strong\u003e total to optimize complex rooftops.\u003c\/li\u003e\n  \u003cli\u003eHigh-flow AC charger: \u003cstrong\u003e90 A\u003c\/strong\u003e multi-stage, profiles for lead-acid and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eBattery system: \u003cstrong\u003e48 V\u003c\/strong\u003e, adjustable parameters and BMS compatibility.\u003c\/li\u003e\n  \u003cli\u003eCommunications and control: \u003cstrong\u003eRS485\u003c\/strong\u003e, dry contact relay, and Solar\/Grid\/Battery priorities.\u003c\/li\u003e\n  \u003cli\u003eComprehensive protections: overload, short circuit, thermal, reverse PV, over\/under voltage DC\/AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial capacity\u003c\/strong\u003e to power multiple critical loads and demanding startups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized PV production\u003c\/strong\u003e with two MPPTs that maximize performance in different orientations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-fast recharge\u003c\/strong\u003e via 90 A charger, minimizing generator run times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLess complexity\u003c\/strong\u003e: a single unit reduces wiring, space, and failure points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAsset protection\u003c\/strong\u003e with appropriate charging curves and coordination with BMS for lithium.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eLarge homes and estates, small hotels, workshops and off-grid businesses, remote stations, telecommunications, and 48 V \u003cem\u003ebackup\u003c\/em\u003e systems where 8 kW continuous, high PV capture, and fast battery recharge are required.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e8 kW (8 kVA) 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBank voltage\u003c\/td\u003e\n\u003ctd\u003e48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT trackers\u003c\/td\u003e\n\u003ctd\u003e2 × MPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input (max Voc)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT current\u003c\/td\u003e\n\u003ctd\u003eUp to 100 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e90 A (multi-stage, lead-acid and LiFePO₄)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWave type\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating modes\u003c\/td\u003e\n\u003ctd\u003eSolar \/ Battery \/ Grid-Generator priority\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, thermal, reverse PV, over\/under voltage, short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use, all-in-one chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003e48 V\u003c\/strong\u003e AGM, GEL, open lead-acid, and \u003cstrong\u003eLiFePO₄\u003c\/strong\u003e banks with BMS. Photovoltaic array with series strings complying with \u003cstrong\u003eVoc ≤ 250 V\u003c\/strong\u003e and total regulator current (100 A). Simple integration with generators and \u003cem\u003eDC\/AC protection\u003c\/em\u003e panels, fuses, disconnectors, and SPD.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTBB Riio Sun II 8 kW 48 V 8KVA-S Inverter Charger\u003c\/strong\u003e is a high-performance all-in-one platform for large off-grid installations that demand reliability and continuous power.\u003c\/p\u003e","brand":"TBB","offers":[{"title":"Default Title","offer_id":51503241986389,"sku":"TBBINVE008","price":1246.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/TBB-RIIO-SUN-II-2_00a52f4a-b2bd-4ded-9d05-9b0a11c47331.png?v=1762628565"},{"product_id":"inversor-victron-easysolar-ii-gx-24v-3000va","title":"Inverter with Charger and MPPT Victron EasySolar-II GX 24V 3000VA 24\/3000\/70-32","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EasySolar-II GX 24V 3000VA 24\/3000\/70-32\u003c\/strong\u003e combines a MultiPlus-II inverter\/charger, a \u003cstrong\u003eSmartSolar MPPT 250\/70\u003c\/strong\u003e controller, and a GX interface with display, Wi-Fi, and Ethernet in a single unit. This integration simplifies wiring, saves installation time, and offers complete control via app or VRM portal. With 3000 VA (2400 W continuous) and \u003cem\u003ePowerAssist\u003c\/em\u003e, it stabilizes the grid or generator, prioritizes self-consumption, and maintains critical loads during outages.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAll-in-one: inverter\/charger, MPPT 250\/70 A, and GX device with display and connectivity.\u003c\/li\u003e\n  \u003cli\u003ePower: 3000 VA \/ 2400 W (peak 5500 W) with pure sine wave and high efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic 32 A switching\u003c\/strong\u003e (“no-break” output) for continuity \u0026lt;20 ms on critical loads.\u003c\/li\u003e\n  \u003cli\u003e24 V \/ 70 A charger with Absorption, Float, and Storage stages for lead-acid and lithium (via BMS-Can).\u003c\/li\u003e\n  \u003cli\u003eMPPT: 250 V max Voc, 70 A output, recommended PV power ≈ 2000 W, efficiency up to 98%.\u003c\/li\u003e\n  \u003cli\u003eInterfaces: BMS-Can, USB, Ethernet, VE.Direct, VE.Bus, and Wi-Fi with free monitoring on VRM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified installation\u003c\/strong\u003e with less space, less wiring, and fewer failure points.\u003c\/li\u003e\n  \u003cli\u003eOptimized self-consumption and \u003cem\u003ezero feed-in\u003c\/em\u003e possible using external clamp\/meter and ESS.\u003c\/li\u003e\n  \u003cli\u003eElectrical continuity for sensitive equipment thanks to ultra-fast transfer.\u003c\/li\u003e\n  \u003cli\u003eAdvanced remote management: configuration, alarms, and history from app and VRM portal with no fees.\u003c\/li\u003e\n  \u003cli\u003eScalable: parallel and three-phase via VE.Bus to grow with the installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHomes and businesses at 24 V with self-consumption and backup, boats and campers, technical or telecom cabins, and off-grid systems where start-up peaks, intelligent management, and remote control are required in a compact format.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInverter power\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W (25 °C); peak 5500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 V (range 19–33 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC transfer\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e32 A\u003c\/strong\u003e automatic; “no-break” output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003e70 A; Abs 28.8 V \/ Float 27.6 V \/ Storage 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003ctd\u003e250 V max Voc; 70 A; PV power ≈ 2000 W; efficiency 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInverter efficiency\u003c\/td\u003e\n\u003ctd\u003e≈ 94%; idle consumption 13 W (search 3 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eMain uninterrupted + auxiliary output (active only with AC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eBMS-Can, USB, Ethernet, VE.Direct, VE.Bus, Wi-Fi; VRM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003e≈ 499 × 268 × 237 mm; ≈ 26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection \/ IP\u003c\/td\u003e\n\u003ctd\u003eFull electronic protections; IP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with current meter\/sensor for zero feed-in, \u003cem\u003eDigital Multi Control\u003c\/em\u003e, \u003cem\u003eVE.Bus Smart Dongle\u003c\/em\u003e, \u003cem\u003eCerbo GX\u003c\/em\u003e, \u003cem\u003eBMV-712\u003c\/em\u003e, or \u003cem\u003eSmartShunt\u003c\/em\u003e. Integrates the solar controller; no external MPPT required.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EasySolar-II GX 24V 3000VA 24\/3000\/70-32\u003c\/strong\u003e concentrates power, management, and connectivity in a compact unit that maximizes self-consumption and ensures continuity at 24 V.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":51503242084693,"sku":"VICTINV054","price":1066.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VICTRON-EASYSOLAR-II-24-3000-1.png?v=1762628570"},{"product_id":"inversor-victron-easysolar-ii-gx-48v-3000va","title":"Inverter with Charger and MPPT Victron EasySolar-II GX 48V 3000VA 48\/3000\/35-32","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EasySolar-II GX 48V 3000VA 48\/3000\/35-32\u003c\/strong\u003e integrates MultiPlus-II, \u003cstrong\u003eSmartSolar MPPT 250\/70\u003c\/strong\u003e and GX device with display in a single chassis. With 3000 VA (2400 W continuous), Wi-Fi\/Ethernet and VRM, it is the compact solution for self-consumption with battery, backup and off-grid at 48 V. The \u003cem\u003ePowerAssist\u003c\/em\u003e function prevents tripping when the AC input is limited and the ESS mode allows zero feed-in with the appropriate meter.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-in-1 device: inverter\/charger, MPPT 250\/70 A and GX gateway with display.\u003c\/li\u003e\n  \u003cli\u003ePower: 3000 VA \/ 2400 W (peak 5500 W) with pure sine wave.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e32 A switching\u003c\/strong\u003e without interruption (\u0026lt;20 ms) for priority loads.\u003c\/li\u003e\n  \u003cli\u003e48 V \/ 35 A charger with lead and lithium profiles (BMS via CAN).\u003c\/li\u003e\n  \u003cli\u003eMPPT: 250 V max Voc, 70 A output; recommended PV power ≈ 4000 W; controller efficiency up to 98%.\u003c\/li\u003e\n  \u003cli\u003eTotal connectivity: VE.Bus, VE.Direct, USB, Ethernet, BMS-Can and Wi-Fi with free management in VRM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation and space savings\u003c\/strong\u003e by integrating inverter, charger and controller in a single unit.\u003c\/li\u003e\n  \u003cli\u003eSmart self-consumption with zero feed-in option and priority control.\u003c\/li\u003e\n  \u003cli\u003eElectrical continuity for sensitive electronics thanks to the “no-break” output.\u003c\/li\u003e\n  \u003cli\u003eScalability: parallel and three-phase via VE.Bus to increase power.\u003c\/li\u003e\n  \u003cli\u003eRemote control from smartphone or web: settings, alarms and history with no fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHomes and SMEs with 48 V battery, marine and special vehicles, technical cabins and off-grid systems that require high peaks, efficient charging and centralized management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInverter power\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W (25 °C); peak 5500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V (range 38–66 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC transfer\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e32 A\u003c\/strong\u003e automatic; “no-break” output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003e35 A; Abs 57.6 V \/ Float 55.2 V \/ Storage 52.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003ctd\u003e250 V max Voc; 70 A; PV power ≈ 4000 W; efficiency 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInverter efficiency\u003c\/td\u003e\n\u003ctd\u003e≈ 95%; idle consumption 11 W (search 2 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eMain uninterrupted + auxiliary output (active only with AC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eBMS-Can, USB, Ethernet, VE.Direct, VE.Bus, Wi-Fi; VRM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003e≈ 499 × 268 × 237 mm; ≈ 26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection \/ IP\u003c\/td\u003e\n\u003ctd\u003eFull electronic protections; IP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with energy sensor\/meter for ESS (zero feed-in), \u003cem\u003eDigital Multi Control\u003c\/em\u003e, \u003cem\u003eVE.Bus Smart Dongle\u003c\/em\u003e, \u003cem\u003eCerbo GX\u003c\/em\u003e, \u003cem\u003eBMV-712\u003c\/em\u003e or \u003cem\u003eSmartShunt\u003c\/em\u003e. The MPPT 250\/70 is integrated; no external controller required.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EasySolar-II GX 48V 3000VA 48\/3000\/35-32\u003c\/strong\u003e offers a compact and professional solution that maximizes self-consumption, ensures continuity and simplifies your 48 V system.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":51503242182997,"sku":"VICTINV055","price":1066.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VICTRON-EASYSOLAR-II-48-3000-1.png?v=1762628578"},{"product_id":"inversor-victron-easysolar-ii-gx-48v-5000va","title":"Inverter with Charger and MPPT Victron EasySolar-II GX 48V 5000VA 48\/5000\/70-50","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EasySolar-II GX 48V 5000VA 48\/5000\/70-50\u003c\/strong\u003e is an “all-in-one” solution that combines a 5 kVA MultiPlus-II inverter\/charger, a \u003cstrong\u003eSmartSolar MPPT 250\/100\u003c\/strong\u003e controller, and a GX interface with display, Wi-Fi, and Ethernet in a single chassis. Designed for demanding 48 V installations, it simplifies system design, reduces wiring and potential failure points, and offers full control via the app and VRM portal. With PowerAssist, it prioritizes self-consumption, prevents tripping when the grid or generator is limited, and maintains critical loads during outages with an ultra-fast 50 A transfer.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-in-1 integration: 5 kVA inverter\/charger, \u003cstrong\u003eMPPT 250\/100\u003c\/strong\u003e, and GX device with display and connectivity.\u003c\/li\u003e\n  \u003cli\u003eInverter power: 5000 VA (≈4000 W continuous at 25 °C) with peaks up to 9000 W for difficult starts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic 50 A switching\u003c\/strong\u003e (“no-break” output) with imperceptible transfer time (\u0026lt;20 ms).\u003c\/li\u003e\n  \u003cli\u003e48 V \/ 70 A battery charger with Absorption, Float, and Storage profiles for lead-acid and lithium (BMS via CAN).\u003c\/li\u003e\n  \u003cli\u003eHigh-performance MPPT: 250 V max Voc, 100 A output, and recommended PV power ≈ 5–6 kWp.\u003c\/li\u003e\n  \u003cli\u003eComprehensive connectivity: VE.Bus, VE.Direct, USB, Ethernet, BMS-Can, and Wi-Fi with free monitoring on VRM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact and clean installation\u003c\/strong\u003e: less space, less wiring, and fewer possible failures.\u003c\/li\u003e\n  \u003cli\u003eOptimized self-consumption and \u003cem\u003ezero feed-in\u003c\/em\u003e option with clamp\/energy meter and ESS mode.\u003c\/li\u003e\n  \u003cli\u003eElectrical continuity for sensitive equipment thanks to the “no-break” output and 50 A transfer.\u003c\/li\u003e\n  \u003cli\u003eRemote management and diagnostics from mobile or web, with history, alarms, and settings without fees.\u003c\/li\u003e\n  \u003cli\u003eProfessional scalability: parallel and\/or three-phase operation via VE.Bus to grow with demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for homes and businesses with 48 V systems seeking to maximize self-consumption with backup, high-consumption boats and special vehicles, technical cabins, and isolated microgrids with generators, where high peaks, efficient charging, and centralized control in a single device are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInverter power\u003c\/td\u003e\n\u003ctd\u003e5000 VA \/ ≈4000 W (25 °C); peak ≈9000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V (DC range ≈38–66 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC transfer\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e50 A\u003c\/strong\u003e automatic; main “no-break” output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003e70 A; Abs 57.6 V \/ Float 55.2 V \/ Storage 52.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIntegrated MPPT\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e250\/100\u003c\/strong\u003e: max Voc 250 V; I\u003csub\u003eout\u003c\/sub\u003e 100 A; recommended PV power ≈ 5–6 kWp; efficiency up to 98 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInverter efficiency\u003c\/td\u003e\n\u003ctd\u003e≈96 %; idle consumption ≈18 W (AES ≈12 W \/ search mode ≈2 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eMain uninterrupted + auxiliary output (active only with AC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eVE.Bus, VE.Direct, USB, Ethernet, BMS-Can, and Wi-Fi; VRM portal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection \/ IP\u003c\/td\u003e\n\u003ctd\u003eFull electronic protections; IP21\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003e≈565 × 308 × 237 mm; ≈30–34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +65 °C (active ventilation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with \u003cem\u003eDigital Multi Control\u003c\/em\u003e (current limit\/PowerAssist), \u003cem\u003eVE.Bus Smart Dongle\u003c\/em\u003e (Bluetooth), \u003cem\u003eCerbo GX\u003c\/em\u003e, \u003cem\u003eBMV-712\u003c\/em\u003e or \u003cem\u003eSmartShunt\u003c\/em\u003e monitors, and single\/three-phase energy meters for ESS and zero feed-in. As the MPPT 250\/100 is included, no external solar regulator is required.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron EasySolar-II GX 48V 5000VA 48\/5000\/70-50\u003c\/strong\u003e concentrates power, control, and monitoring in a single professional device that maximizes self-consumption and ensures continuity in 48 V systems.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":51503242281301,"sku":"VICTINV056","price":1498.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VICTRON-EASYSOLAR-II-48-5000-1.png?v=1762628579"},{"product_id":"inversor-victron-multi-rs-solar-48v-6000va","title":"Inverter with Charger and MPPT Victron Multi RS Solar 48V 6000VA 48\/6000","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVictron Multi RS Solar 48V 6000VA 48\/6000 Inverter with Charger and MPPT\u003c\/strong\u003e is a high-performance “all-in-one” for 48 V off-grid systems. It combines a 6 kVA pure sine wave inverter, a fully programmable 100 A battery charger, and a \u003cstrong\u003edual MPPT\u003c\/strong\u003e high-voltage solar charge controller (80–450 V), all in a compact unit with a front display and smart connectivity. Thanks to PowerControl and \u003cstrong\u003ePowerAssist\u003c\/strong\u003e, it prioritizes critical loads, prevents generator\/grid overload, and supplies extra power from the battery during demand peaks. Its high efficiency, wide operating range, and professional-grade protection electronics make it the ideal solution for off-grid homes, marine applications, or technical cabins requiring reliability and advanced control.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6 kVA inverter (≈4.8–5.3 kW depending on battery voltage) with \u003cstrong\u003e9 kW peak\u003c\/strong\u003e for demanding startups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual MPPT 80–450 V\u003c\/strong\u003e up to 6 kWp (≈3 kW per tracker), ideal for long strings and reduced cable cross-section.\u003c\/li\u003e\n  \u003cli\u003eIntegrated battery charger of \u003cstrong\u003e100 A\u003c\/strong\u003e with configurable absorption and float.\u003c\/li\u003e\n  \u003cli\u003ePowerControl\/PowerAssist: intelligent energy management with generator\/grid and 50 A transfer.\u003c\/li\u003e\n  \u003cli\u003eConnectivity: \u003cstrong\u003eBluetooth\u003c\/strong\u003e, \u003cstrong\u003eVE.Can\u003c\/strong\u003e and \u003cstrong\u003eVE.Direct\u003c\/strong\u003e; programmable relay and remote on\/off input.\u003c\/li\u003e\n  \u003cli\u003eFront display with battery, inverter, and solar data; analog I\/O for external sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue all-in-one\u003c\/strong\u003e: fewer devices, less wiring, and lower installation complexity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuality energy\u003c\/strong\u003e: pure sine wave to protect sensitive electronics and appliances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMore PV production\u003c\/strong\u003e: wide MPPT range (80–450 V) allowing higher voltage strings with less loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized autonomy\u003c\/strong\u003e: high efficiency and fine control of thresholds, alarms, and charging modes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntelligent management\u003c\/strong\u003e: configuration\/diagnostics via VictronConnect app or VRM portal through GX device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for off-grid homes with medium\/high consumption, vessels with a 48 V battery bank, telecom and technical cabins, mobile workshops or micro-businesses off-grid that require high continuous power, high peaks, and professional photovoltaic utilization with high-voltage strings.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMulti RS Solar 48\/6000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery (DC input)\u003c\/td\u003e\n\u003ctd\u003e48 V (≈38–62 V; typical start ≥41 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC Output\u003c\/td\u003e\n\u003ctd\u003e230 V ± 2 % | 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eContinuous power\u003c\/td\u003e\n\u003ctd\u003e≈4.8–5.3 kW at 25 °C (depending on Vbat); 4.5 kW at 40 °C; 3 kW at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e9 kW (3 s) \/ 7 kW (≈4 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eGrid transfer \/ pass-through\u003c\/td\u003e\n\u003ctd\u003e50 A switch | Maximum pass-through current 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. efficiency\u003c\/td\u003e\n\u003ctd\u003e≈96.5% (1 kW) | ≈94% (5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo-load consumption\u003c\/td\u003e\n\u003ctd\u003e≈20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV MPPT\u003c\/td\u003e\n\u003ctd\u003e2× (80–450 V; start 120 V) | Max. PV power 6 kWp (≈3 kW per tracker)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV current\u003c\/td\u003e\n\u003ctd\u003eI\u003csub\u003eoper\u003c\/sub\u003e max. ≈13 A (limit ≈20 A); I\u003csub\u003esc\u003c\/sub\u003e max. ≈16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003e100 A; Absorption approx. 57.6 V (adjustable); Float approx. 55.2 V (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eBluetooth, VE.Can, VE.Direct; analog I\/O; remote on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProgrammable relay\u003c\/td\u003e\n\u003ctd\u003eYes (alarm \/ DC undervoltage \/ generator start)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eMain AC-out + AC-out-2 for non-critical loads\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eShort circuit, overload, high\/low Vbat, overtemperature, 230 V on output, earth leakage (solar)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003e≈425 × 460 × 125 mm \/ ≈12.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel \/ Three-phase\u003c\/td\u003e\n\u003ctd\u003eSupports three-phase systems with 1 unit per phase (no parallel on the same phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eIntegration with Cerbo GX \/ Color Control GX (VRM monitoring), SmartShunt or BMV-712 Smart, VE.Direct-USB interface, Filax transfer switch, DC Lynx distribution (busbars and fuses), battery temperature\/voltage sensors, and remote input compatible with Victron BMS. Use MEGA\/MIDI fuses, DC isolator, and DC circuit breaker sized to the system.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eVictron Multi RS Solar 48V 6000VA 48\/6000 Inverter with Charger and MPPT\u003c\/strong\u003e provides professional-grade continuous power, dual high-voltage MPPT, and intelligent management to maximize the performance of your 48 V off-grid installation.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":51503242379605,"sku":"VICTINV097","price":1522.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VICTRON-MULTI-RS-48-6000-1.png?v=1762628586"},{"product_id":"inversor-voltronic-king-3k-3000w-24v-mppt","title":"Off-Grid Inverter Voltronic Axpert KING 3K 3000W 24V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING 3K 3000W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e is an “all-in-one” device designed for off-grid systems that require continuity, control, and high reliability. It integrates a 3000 W pure sine wave inverter, battery charger, and \u003cstrong\u003e60 A MPPT solar charge controller\u003c\/strong\u003e with a tracking window of 30–115 V and a \u003cstrong\u003emaximum Voc of 145 V\u003c\/strong\u003e. Its distinguishing feature is the \u003cstrong\u003e0 ms transfer\u003c\/strong\u003e, which protects critical loads by ensuring no perceptible interruption between sources. It includes \u003cstrong\u003eBluetooth\u003c\/strong\u003e for mobile monitoring, a \u003cstrong\u003eremovable LCD display\u003c\/strong\u003e that acts as a remote panel, and parallel operation capability for up to 9 units to increase power.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power: 3000 VA \/ 3000 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003eSolar charge controller: \u003cstrong\u003eMPPT 30–115 V, 60 A\u003c\/strong\u003e; max PV power 1500 W; max Voc 145 V.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e0 ms transfer\u003c\/strong\u003e and 6000 VA peak (5 s) for startups and sensitive loads.\u003c\/li\u003e\n  \u003cli\u003eAC charger up to 60 A; combined AC + solar charging up to 120 A.\u003c\/li\u003e\n  \u003cli\u003eCommunications: USB, RS232, RS485, \u003cstrong\u003eBluetooth\u003c\/strong\u003e, and dry contact; reserved port for BMS (RS485\/CAN\/RS232).\u003c\/li\u003e\n  \u003cli\u003eParallel operation for up to 9 units; removable LCD for remote installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal continuity\u003c\/strong\u003e for servers, routers, POS terminals, or sensitive electronics thanks to 0 ms transfer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreater harvesting\u003c\/strong\u003e compared to PWM with 60 A MPPT and strings up to 115 V in operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexibility\u003c\/strong\u003e to prioritize solar, battery, or grid\/generator and extend the life of the 24 V battery bank.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eScalability\u003c\/strong\u003e through parallel operation (up to 9) and progressive expansion of the PV array.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple management\u003c\/strong\u003e with APP (Bluetooth) and removable LCD that facilitates configuration and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for off-grid homes, country houses, farms, light workshops, telecom, and remote offices that require stable 230 VAC from a 24 V battery bank. Also useful as a backup system with generator in locations with unstable grid.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave, 230 VAC ±5 %, THDv ≤3 % (linear load)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e6000 VA (5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency (line \/ battery)\u003c\/td\u003e\n\u003ctd\u003e≈93 % \/ ≈90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e24 VDC (float 27 V; overload protection 34 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV charge controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 30–115 V, 60 A; max Voc 145 V; max PV 1500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax combined charging\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e230 VAC, 110–280 VAC; 50\/60 Hz auto\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ Bluetooth \/ dry contact; reserved BMS port\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 × 303 × 525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e13.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0–55 °C; 5–95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 24 V battery banks (AGM\/GEL lead-acid and lithium with suitable parameters), 230 VAC generator\/grid, and PV array within indicated limits. Recommended accessories (no URL): DC\/AC protections, battery fuses and fuse holders, disconnectors, solar and power cabling, panel mounting structures, and monitoring kits.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING 3K 3000W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e provides absolute continuity, advanced management, and excellent performance-to-price ratio for your 24 V off-grid installation.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503242641749,"sku":"VOLTINV007","price":540.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-KING.png?v=1762628592"},{"product_id":"inversor-voltronic-king-5k-5000w-48v-mppt","title":"Off-Grid Inverter Voltronic Axpert KING 5K 5000W 48V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING 5K 5000W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e is designed for off-grid installations that require higher continuous power and a high level of load protection. It integrates a 5000 W pure sine wave inverter, battery charger, and \u003cstrong\u003e80 A MPPT solar charge controller\u003c\/strong\u003e with a 60–115 V window and \u003cstrong\u003emaximum Voc 145 V\u003c\/strong\u003e, supporting up to \u003cstrong\u003e4000 W\u003c\/strong\u003e of photovoltaic power. Its \u003cstrong\u003e0 ms\u003c\/strong\u003e transfer ensures continuity for critical equipment; it also features \u003cstrong\u003eBluetooth\u003c\/strong\u003e, \u003cstrong\u003eremovable LCD\u003c\/strong\u003e, and parallel operation of up to 9 units for scalable growth.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 5000 VA \/ 5000 W at 230 VAC with \u003cstrong\u003epure sine wave\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003ePV controller: \u003cstrong\u003eMPPT 60–115 V, 80 A\u003c\/strong\u003e; max PV 4000 W; max Voc 145 V.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e0 ms\u003c\/strong\u003e transfer and \u003cstrong\u003e10,000 VA\u003c\/strong\u003e peak (5 s) for demanding startups.\u003c\/li\u003e\n  \u003cli\u003eAC charger 60 A; total charging current (AC + solar) up to 140 A.\u003c\/li\u003e\n  \u003cli\u003eInterface: USB, RS232, RS485, Bluetooth, and dry contact; reserved port for BMS (RS485\/CAN\/RS232).\u003c\/li\u003e\n  \u003cli\u003eParallel operation up to 9 units; removable LCD screen as remote panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior power\u003c\/strong\u003e for large homes, workshops, and SMEs with medium-high consumption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCritical load protection\u003c\/strong\u003e without perceptible interruptions thanks to 0 ms transfer and pure sine wave.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreater harvesting\u003c\/strong\u003e with 80 A MPPT and strings up to 115 V, optimizing daily performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue scalability\u003c\/strong\u003e with parallel operation (up to 9) and progressive photovoltaic expansion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConvenient management\u003c\/strong\u003e via APP (Bluetooth) and remote LCD for easy adjustments and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for larger off-grid residences, light agro-industry, remote offices, telecom, or small businesses seeking stable 230 VAC from a 48 V battery bank with guarantees of continuity and centralized control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e5000 VA \/ 5000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave, 230 VAC ±5 %, THDv ≤3 % (linear load)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e10,000 VA (5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency (line \/ battery)\u003c\/td\u003e\n\u003ctd\u003e≈93 % \/ ≈90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e48 VDC (float 54 V; overcharge protection 66 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller\u003c\/td\u003e\n\u003ctd\u003eMPPT 60–115 V, 80 A; max Voc 145 V; max PV 4000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax combined charging\u003c\/td\u003e\n\u003ctd\u003e140 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e230 VAC, 110–280 VAC; 50\/60 Hz auto\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ Bluetooth \/ dry contact; reserved BMS port\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 × 303 × 525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e13.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0–55 °C; 5–95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 48 V battery banks (AGM\/GEL lead-acid and lithium with suitable parameters), generator\/grid 230 VAC, and PV strings within 60–115 V in operation (Voc ≤ 145 V). Recommended accessories (no URL): DC\/AC protections, battery fuses and fuse holders, disconnectors, solar and power cabling, structures, and monitoring kits.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING 5K 5000W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e combines power, 0 ms continuity, and advanced control to reliably meet the demands of demanding and expanding 48 V off-grid installations.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503242740053,"sku":"VOLTINV008","price":562.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-KING_cc3243b2-3a53-487f-91c0-99cc484890d1.png?v=1762628596"},{"product_id":"inversor-voltronic-king-ii-5000-48-5000w-48v-mppt","title":"Off-Grid Inverter Voltronic Axpert KING II-5000-48 5000W 48V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING II-5000-48 5000W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e is an all-in-one solution for demanding solar systems, integrating a pure sine wave inverter, battery charger, and high-performance photovoltaic controller. Its key feature is \u003cstrong\u003e0 ms\u003c\/strong\u003e transfer, which keeps critical loads operational without noticeable interruptions when the power source changes. The wide input range of the \u003cstrong\u003eMPPT 120–430 V\u003c\/strong\u003e (max Voc 500 V) allows for higher voltage strings and more efficient wiring, while the integrated \u003cstrong\u003eWi-Fi\u003c\/strong\u003e and \u003cstrong\u003eremovable LCD display\u003c\/strong\u003e facilitate local and remote monitoring and configuration. In addition, it supports parallel operation of up to 9 units to scale power and redundancy in professional projects.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 5000 VA \/ 5000 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e output at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003eSolar controller: \u003cstrong\u003eMPPT 120–430 V\u003c\/strong\u003e, max Voc 500 V, \u003cstrong\u003e100 A\u003c\/strong\u003e and up to \u003cstrong\u003e6000 W\u003c\/strong\u003e PV power.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e0 ms\u003c\/strong\u003e transfer (AC→battery) and typical return 4 ms (inverter→bypass).\u003c\/li\u003e\n  \u003cli\u003eBattery bank: 48 V (range 40–66 V); float 54 V; overload protection 66 V.\u003c\/li\u003e\n  \u003cli\u003eProgrammable AC charging up to \u003cstrong\u003e100 A\u003c\/strong\u003e; efficiencies: line 94%, ECO 98%, battery 92%.\u003c\/li\u003e\n  \u003cli\u003eParallelizable \u003cstrong\u003eup to 9 units\u003c\/strong\u003e; removable LCD and \u003cstrong\u003eWi-Fi\u003c\/strong\u003e for mobile APP.\u003c\/li\u003e\n  \u003cli\u003eCommunications: USB, RS232, RS485, dry contact, and reserved port for \u003cstrong\u003eBMS (RS485\/CAN-Bus)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal continuity\u003c\/strong\u003e for sensitive equipment (IT, telecom, POS) thanks to 0 ms switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMore production\u003c\/strong\u003e and less loss with high-voltage PV strings and 100 A MPPT.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced management\u003c\/strong\u003e: monitor via Wi-Fi, configure from the remote LCD, and log events.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue scalability\u003c\/strong\u003e with parallel operation and high-current AC\/PV charging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified installation\u003c\/strong\u003e: inverter + charger + MPPT in a single compact unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for continuously used off-grid homes, light agro-industry, workshops, and remote offices with medium-high power needs. It is also suitable as a backup system in locations with an unstable grid or with an auxiliary generator where stability at 230 VAC and centralized management of the 48 V system are required.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e5000 VA \/ 5000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave, 230 VAC ±5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer\u003c\/td\u003e\n\u003ctd\u003e0 ms (AC→battery); 4 ms typical (inverter→bypass)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eLine 94%; ECO 98%; battery 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e48 VDC (40–66 V); float 54 V; protection 66 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eMPPT 120–430 V; max Voc 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax solar current\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAdmissible PV power\u003c\/td\u003e\n\u003ctd\u003e6000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e230 VAC; 110–280 VAC; 50\/60 Hz auto\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput THD\u003c\/td\u003e\n\u003ctd\u003e≤3% (linear load); ≤5% (non-linear)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232, RS485, Wi-Fi, dry contact; BMS port (RS485\/CAN)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e140 × 295 × 468 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C; 5–95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 48 V battery banks (AGM\/GEL lead-acid and lithium with compatible BMS), PV array within 120–430 V (Voc ≤ 500 V), and 230 VAC grid\/generator. Recommended accessories: DC\/AC protections, fuses and fuse holders for battery, disconnect switches, 1000\/1500 V solar cabling, panel mounting structures, and monitoring kits.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING II-5000-48 5000W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e combines 0 ms continuity, high PV performance, and professional connectivity to take your 48 V off-grid installations to a higher level of reliability and control.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503242838357,"sku":"VOLTINV009","price":608.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-KING-II.png?v=1762628601"},{"product_id":"inversor-voltronic-king-rack-5k-48v-5000w-48v-mppt","title":"Off-Grid Inverter Voltronic Axpert KING Rack 5K-48V 5000W 48V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING Rack 5K-48V 5000W 48V MPPT Isolated Inverter\u003c\/strong\u003e is designed for professional off-grid installations seeking continuous power, absolute continuity, and a clean cabinet-mounted setup. Its “all-in-one” architecture combines a 5000 W pure sine wave inverter, battery charger, and high-performance MPPT solar controller, reducing wiring, space, and installation time. The 19” rack format facilitates integration in technical rooms, micro data centers, or electrical cabinets, and its electronics with \u003cstrong\u003e0 ms transfer\u003c\/strong\u003e protect critical loads against micro-outages when the power source changes.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power: 5000 VA \/ 5000 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e output at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003ePhotovoltaic regulator: \u003cstrong\u003eMPPT 60–115 V\u003c\/strong\u003e, \u003cstrong\u003e80 A\u003c\/strong\u003e, \u003cstrong\u003emax Voc 145 V\u003c\/strong\u003e and up to 4000 W PV.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e0 ms transfer\u003c\/strong\u003e for sensitive loads (IT, routers, POS, industrial control).\u003c\/li\u003e\n  \u003cli\u003ePeak power: \u003cstrong\u003e10,000 VA (5 s)\u003c\/strong\u003e for motor startup and dynamic loads.\u003c\/li\u003e\n  \u003cli\u003eAC charger up to 60 A; combined charging (solar + AC) up to \u003cstrong\u003e140 A\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eParallel operation up to 9 units to increase power, redundancy, or phases.\u003c\/li\u003e\n  \u003cli\u003eCommunications: USB, RS232, RS485, dry contact, and Wi-Fi; \u003cstrong\u003ereserved port for BMS (RS485\/CAN\/RS232)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGuaranteed continuity\u003c\/strong\u003e: 0 ms avoids restarts and protects critical electronics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency and order\u003c\/strong\u003e: 19” rack format for standardized cabinets and agile maintenance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior solar performance\u003c\/strong\u003e with 80 A MPPT and strings up to 115 V in operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue scalability\u003c\/strong\u003e: parallelization up to 9 units for staged growth.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReady for lithium\u003c\/strong\u003e: dedicated BMS port simplifies integration with 48 V batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for high-consumption isolated homes and estates, telecom and radio links, technical rooms, pumping, and small businesses in areas without grid or with generator. Its rack mounting makes it perfect where organized, modular solutions with central supervision are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e5000 VA \/ 5000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e10,000 VA (5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency (line \/ battery)\u003c\/td\u003e\n\u003ctd\u003e≈93 % \/ ≈90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC (float 54 V; protection 66 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV regulator\u003c\/td\u003e\n\u003ctd\u003eMPPT 60–115 V, 80 A; max PV 4000 W; max Voc 145 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax total charge\u003c\/td\u003e\n\u003ctd\u003e140 A (AC + PV)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e230 VAC; 110–280 VAC; 50\/60 Hz auto\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTHDv output\u003c\/td\u003e\n\u003ctd\u003e≤3 % (linear load) \/ ≤8 % (non-linear)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ Wi-Fi \/ dry contact; BMS port (RS485\/CAN\/RS232)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (D × W × H)\u003c\/td\u003e\n\u003ctd\u003e466.3 × 438 × 130.8 mm (rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≈15.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C; RH 5–95 % (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 48 V battery banks (AGM\/GEL and lithium with BMS via RS485\/CAN), PV array within 60–115 V in operation (Voc ≤ 145 V), and generator\/grid 230 VAC. Recommended accessories: DC\/AC protections, battery fuses\/fuse holders, disconnectors, 1000\/1500 V solar cabling, ventilated 19” rack cabinet, and monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert KING Rack 5K-48V 5000W 48V MPPT Isolated Inverter\u003c\/strong\u003e provides stable power, 0 ms continuity, and a modular rack design that enhances the reliability and organization of any modern off-grid installation.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503242936661,"sku":"VOLTINV010","price":659.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-KING-RACK.png?v=1762628604"},{"product_id":"inversor-voltronic-axpert-ultra-11k-11000w-48v-mppt","title":"Off-Grid Inverter Voltronic Axpert Ultra 11K 11000W 48V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert Ultra 11K 11000W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e is the highest power version of the Ultra family, designed for large and demanding off-grid installations. It integrates an 11 kW pure sine wave inverter, battery charger, and \u003cstrong\u003etwo independent MPPTs\u003c\/strong\u003e (90–450 V) that support up to \u003cstrong\u003e12 kW PV\u003c\/strong\u003e (2×6 kW). Includes \u003cstrong\u003eWi-Fi\u003c\/strong\u003e for monitoring and OTA updates, 2.8” color touchscreen, \u003cstrong\u003einternal current sensor\u003c\/strong\u003e for self-consumption with export limitation, and \u003cstrong\u003edual AC outputs\u003c\/strong\u003e to prioritize critical loads. Its architecture allows parallel operation of up to 6 units to increase power or create three-phase systems.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power: 11,000 VA \/ 11,000 W; \u003cstrong\u003epure sine wave\u003c\/strong\u003e output 230 VAC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual MPPT 90–450 V\u003c\/strong\u003e, Voc 500 V, up to \u003cstrong\u003e12 kW PV\u003c\/strong\u003e and \u003cstrong\u003e150 A\u003c\/strong\u003e solar charging.\u003c\/li\u003e\n  \u003cli\u003ePV inputs: 2×27 A (max. 40 A); optimal for long strings and different orientations.\u003c\/li\u003e\n  \u003cli\u003eFast transfer 10\/20 ms; start-up peak of \u003cstrong\u003e22 kVA\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eParallelization up to \u003cstrong\u003e6 units\u003c\/strong\u003e; load management via dual AC outputs.\u003c\/li\u003e\n  \u003cli\u003eConnectivity: USB, RS232, RS485, Wi-Fi, and dry contact; reserved port for BMS (RS485\/CAN\/RS232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior capacity\u003c\/strong\u003e for large homes, workshops, agricultural operations, and SMEs with high demand.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximized PV production\u003c\/strong\u003e with two high-voltage MPPTs and up to 12 kW solar array.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControlled self-consumption\u003c\/strong\u003e thanks to the integrated CT and load prioritization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eScalability\u003c\/strong\u003e with parallel operation (up to 6) and the possibility of multiphase systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable operation\u003c\/strong\u003e with fast switching, pure sine wave, and comprehensive protections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for large off-grid residences, micro-industries, farms, rural hotels, telecom, and businesses seeking stable 230 VAC from 48 V, with high solar contribution and intelligent load management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e11,000 VA \/ 11,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e22 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e10 ms (PC) \/ 20 ms (Home)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e48 VDC; float 54 V; protection 63 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eDual MPPT 90–450 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. PV Voc\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. PV power\u003c\/td\u003e\n\u003ctd\u003e12 kW (2×6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. PV current\u003c\/td\u003e\n\u003ctd\u003e2×27 A (max. 40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. solar charging\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. AC charger\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. total charging\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eDual output for essential\/non-essential loads\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eExternal sensor\u003c\/td\u003e\n\u003ctd\u003eIntegrated CT for self-consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ Wi-Fi \/ dry contact \/ BTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e145 × 438 × 553.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e18.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C; 5–95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 48 V battery banks (AGM\/GEL and lithium with BMS via RS485\/CAN), generator\/grid 230 VAC, and PV arrays within 90–450 V (Voc ≤ 500 V). Recommended accessories: DC\/AC protections, battery fuses, disconnectors, 1000\/1500 V solar cabling, mounting structures, and monitoring solutions.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert Ultra 11K 11000W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e is a powerful, modern, and scalable solution to reliably tackle large-scale off-grid projects.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243034965,"sku":"VOLTINV012","price":1029.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-ULTRA-11K.png?v=1762628606"},{"product_id":"inversor-voltronic-axpert-ultra-8k-8000w-48v-mppt","title":"Voltronic Axpert Ultra 8K 8000W 48V MPPT Off-Grid Inverter","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert Ultra 8K 8000W 48V MPPT Isolated Inverter\u003c\/strong\u003e is designed for off-grid installations that require high power, flexibility, and advanced control. It combines an 8000 W pure sine wave inverter, battery charger, and \u003cstrong\u003etwo independent MPPT solar controllers\u003c\/strong\u003e with a wide range of 90–450 V, allowing for high-voltage strings, fewer cable sections, and a more efficient PV design. It features \u003cstrong\u003eWi-Fi\u003c\/strong\u003e for monitoring and OTA updates, a 2.8” color display with slide operation, \u003cstrong\u003edual AC outputs\u003c\/strong\u003e for intelligent load management, and an \u003cstrong\u003eintegrated current sensor\u003c\/strong\u003e that enables self-consumption mode with export limitation.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 8000 VA \/ 8000 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual MPPT 90–450 V\u003c\/strong\u003e, max PV Voc 500 V, up to \u003cstrong\u003e10 kW PV\u003c\/strong\u003e (2×5 kW) and \u003cstrong\u003e150 A\u003c\/strong\u003e solar charging.\u003c\/li\u003e\n  \u003cli\u003eIndependent PV inputs: 2×27 A (max. 40 A) to configure two arrays or orientations.\u003c\/li\u003e\n  \u003cli\u003eFast transfer: 10 ms (PC) \/ 20 ms (appliances). Peak: \u003cstrong\u003e16 kVA\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eParallelizable up to \u003cstrong\u003e6 units\u003c\/strong\u003e to increase power or phases.\u003c\/li\u003e\n  \u003cli\u003eCommunications: USB, RS232, RS485, Wi-Fi, dry contact, and reserved port for BMS (RS485\/CAN\/RS232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher production\u003c\/strong\u003e thanks to high-voltage MPPT and two PV inputs for east\/west or expansions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOff-grid self-consumption\u003c\/strong\u003e with integrated current sensor that prioritizes loads and limits exports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuity\u003c\/strong\u003e with fast switching and pure sine wave that protects sensitive electronics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue scalability\u003c\/strong\u003e: parallelization (up to 6) and up to 10 kW PV supported.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional management\u003c\/strong\u003e with Wi-Fi, color LCD, and internal logs for diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHomes and isolated properties with medium-high consumption, light agro-industry, workshops, telecommunications, radio links, and businesses in areas without grid or with generator. Ideal when a modular, expandable system with controlled self-consumption is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e8000 VA \/ 8000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e16 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e10 ms (PC) \/ 20 ms (Home)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e93 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e48 VDC; float 54 V; protection 63 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eDual MPPT 90–450 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV power\u003c\/td\u003e\n\u003ctd\u003e10 kW (2×5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV current\u003c\/td\u003e\n\u003ctd\u003e2×27 A (max. 40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax solar charging\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax total charging\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eDual output for critical\/non-critical loads\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eExternal sensor\u003c\/td\u003e\n\u003ctd\u003eIntegrated CT for self-consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ Wi-Fi \/ dry contact \/ BTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e145 × 438 × 553.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e18.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C; 5–95 % RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 48 V battery banks (AGM\/GEL and lithium with BMS via RS485\/CAN), 230 VAC generator\/grid, and PV arrays within 90–450 V (Voc ≤ 500 V). Recommended accessories: DC\/AC protections, battery fuses and fuse holders, disconnectors, 1000\/1500 V solar cable, panel mounting structures, and monitoring kits.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert Ultra 8K 8000W 48V MPPT Isolated Inverter\u003c\/strong\u003e offers a robust and expandable platform to take your off-grid installation to a higher level of performance and control.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243133269,"sku":"VOLTINV011","price":930.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-ULTRA-8K.png?v=1762628609"},{"product_id":"inversor-voltronic-vm-3000-24-3000w-24v-mppt","title":"Off-Grid Inverter Voltronic Axpert VM 3000-24 3000W 24V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM 3000-24 3000W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e is an “all-in-one” solution for off-grid solar systems that combines a pure sine wave inverter, battery charger, and a \u003cstrong\u003e60 A MPPT photovoltaic controller\u003c\/strong\u003e. Designed for \u003cstrong\u003e24 V\u003c\/strong\u003e battery banks, it supplies stable 230 VAC to domestic and professional loads, optimizes solar capture through maximum power point tracking, and allows you to set energy priority (solar, grid, or generator) to extend battery life and reduce costs.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 3000 VA \/ 3000 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e output at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PV controller: \u003cstrong\u003eMPPT 60 A\u003c\/strong\u003e, typical tracking window 60–115 V and \u003cstrong\u003emax Voc 145 V\u003c\/strong\u003e; recommended PV power up to 1500 W at 24 V.\u003c\/li\u003e\n  \u003cli\u003eBattery: 24 VDC; AC charger up to 40 A; combined charging current up to 100 A.\u003c\/li\u003e\n  \u003cli\u003eFast switching: 10 ms (IT loads) \/ 20 ms (standard loads).\u003c\/li\u003e\n  \u003cli\u003ePeak inverter efficiency 90–93 % with 230 VAC ±5 % regulation.\u003c\/li\u003e\n  \u003cli\u003eAdvanced functions: cold start, programmable solar\/AC priority, equalization (lead-acid), LCD display, integrated protections, and USB\/RS232 communications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher performance\u003c\/strong\u003e with MPPT compared to PWM: more daily energy in cold climates or with variable irradiance.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAll-in-one\u003c\/strong\u003e architecture simplifies wiring, reduces space, and speeds up commissioning.\u003c\/li\u003e\n  \u003cli\u003eOperational flexibility: choose whether to prioritize solar, battery, or grid\/generator depending on the season or usage profile.\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive equipment thanks to pure sine wave and fast switching.\u003c\/li\u003e\n  \u003cli\u003eScalability: allows expansion of the PV array within the controller’s limits and growth as consumption increases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for continuously used off-grid homes, farms, light workshops, remote offices, telecom, and small commercial installations where stable 230 VAC is required from a 24 V bank with efficient solar capture and centralized control.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5 %, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e10 ms (PC) \/ 20 ms (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e90–93 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003eUp to 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax combined charging\u003c\/td\u003e\n\u003ctd\u003eUp to 100 A (AC + solar)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType of PV controller\u003c\/td\u003e\n\u003ctd\u003eIntegrated MPPT 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT window\u003c\/td\u003e\n\u003ctd\u003e60–115 VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e145 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRecommended PV power\u003c\/td\u003e\n\u003ctd\u003e≈1500 W in 24 V systems\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload, short circuit, overtemperature, reverse polarity, etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈100 × 300 × 440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≈7.0–7.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 24 V battery banks (lead-acid, AGM\/GEL, and lithium with suitable parameters), 230 VAC generator or grid, and PV array within the indicated Voc\/MPPT limits. Recommended accessories: DC\/AC protections, fuses and fuse holders for battery, solar and power cabling, panel mounting structure, and monitoring kits via USB\/RS232. If you have related internal products, link them here with their URL.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM 3000-24 3000W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e is a solid and efficient solution for off-grid projects seeking higher solar production, intelligent management, and reliability at 24 V with a single integrated device.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243231573,"sku":"VOLTINV003","price":313.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-VM-24-3000-1.png?v=1762628611"},{"product_id":"inversor-voltronic-vm-iii-3000-24-3000w-24v-mppt","title":"Off-Grid Inverter Voltronic Axpert VM III-3000-24 3000W 24V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM III-3000-24 3000W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e is a next-generation all-in-one solution for off-grid solar installations seeking efficiency, control, and versatility. It integrates a 3000 W pure sine wave inverter, battery charger, and a \u003cstrong\u003e100 A MPPT solar charge controller\u003c\/strong\u003e with a wide operating window (120–450 V), allowing for higher voltage photovoltaic strings and more efficient cabling. Includes integrated WiFi for mobile monitoring, a removable LCD screen (usable as a remote panel up to 20 m), dual programmable AC output, and a key feature: it can supply power to loads from PV or grid even \u003cstrong\u003ewithout a battery\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 3000 VA \/ 3000 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPPT 100 A\u003c\/strong\u003e with 120–450 V range and max PV Voc 500 V; allowable PV power up to 4000 W.\u003c\/li\u003e\n  \u003cli\u003e“Battery independence” function: operation and load supply from PV\/grid without a connected battery.\u003c\/li\u003e\n  \u003cli\u003eDual AC output: configurable for critical loads or as generator input.\u003c\/li\u003e\n  \u003cli\u003eFast transfer: 15 ms (PC) \/ 20 ms (appliances) and 6000 VA peak.\u003c\/li\u003e\n  \u003cli\u003eAdvanced connectivity: WiFi, USB\/RS232\/RS485, and dry contact; detachable LCD as remote panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher production\u003c\/strong\u003e thanks to high-voltage MPPT, ideal for variable climates and long strings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified installation\u003c\/strong\u003e: all integrated (inverter + charger + controller), less cabling and time savings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational flexibility\u003c\/strong\u003e: prioritizes solar, battery, or grid\/generator according to season or consumption profile.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eService continuity\u003c\/strong\u003e with dual AC output for critical loads and fast switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple management and maintenance\u003c\/strong\u003e with mobile app, remote LCD, replaceable fans, and lead battery equalization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuously used off-grid homes, agricultural operations, small workshops, telecom, remote offices, or businesses in areas without reliable grid. Its batteryless mode and dual AC output make it especially useful when continuity for priority loads and maximum operational flexibility are required.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e15 ms (PC) \/ 20 ms (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e90–93 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFloat \/ overcharge voltage\u003c\/td\u003e\n\u003ctd\u003e27 V \/ 33 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eIntegrated MPPT 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPPT range\u003c\/td\u003e\n\u003ctd\u003e120–450 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV power\u003c\/td\u003e\n\u003ctd\u003e4000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003eUp to 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax combined charge\u003c\/td\u003e\n\u003ctd\u003eUp to 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC inputs (grid\/generator)\u003c\/td\u003e\n\u003ctd\u003e230 VAC; selectable range 170–280 VAC (PC) \/ 90–280 VAC (Home)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC outputs\u003c\/td\u003e\n\u003ctd\u003eDual programmable AC output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eWiFi, USB, RS232, RS485, dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDetachable LCD (remote panel up to 20 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e115 × 300 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C (5–95 % RH, non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 24 V battery banks (lead-acid, AGM\/GEL, and lithium with suitable parameters; reserved port for BMS via RS-485\/CAN), PV array within 120–450 V (Voc \u0026lt;= 500 V), and 230 VAC generator\/grid. Recommended accessories: DC\/AC protections, battery fuses and fuse holders, disconnectors, solar and power cabling, panel mounting structures, and monitoring kits (USB\/RS232\/RS485).\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM III-3000-24 3000W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e combines high photovoltaic performance, advanced control, and batteryless operation to offer a robust, scalable, and high-value platform for demanding off-grid projects.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243362645,"sku":"VOLTINV004","price":324.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-VMIII-1.png?v=1762628613"},{"product_id":"inversor-voltronic-vm-iv-3600-24-3600w-24v-mppt","title":"Off-Grid Inverter Voltronic Axpert VM IV 3600-24 3600W 24V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM IV 3600-24 3600W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e is a next-generation all-in-one solution for off-grid systems that demand higher performance and control. It integrates a 3600 W pure sine wave inverter, battery charger, and a \u003cstrong\u003eMPPT solar controller 120–450 V \/ 120 A\u003c\/strong\u003e, allowing high-voltage photovoltaic strings with efficient wiring and reduced losses. Its WiFi connectivity enables monitoring from an app, while the \u003cstrong\u003e4.3” touch LCD display\u003c\/strong\u003e and \u003cstrong\u003eRGB LED ring\u003c\/strong\u003e enhance interaction and status visualization. Additionally, it features a battery-independent design to operate and supply loads from PV\/grid even without a connected battery.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power: 3600 VA \/ 3600 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e output at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPPT 120–450 V (max Voc 500 V) and 120 A\u003c\/strong\u003e; supports up to 4000 W PV.\u003c\/li\u003e\n  \u003cli\u003eAC input with selectable range: 170–280 VAC (PC) \/ 90–280 VAC (Home).\u003c\/li\u003e\n  \u003cli\u003eFast transfer: 15 ms (PC) \/ 20 ms (appliances); peak 7200 VA.\u003c\/li\u003e\n  \u003cli\u003eCommunications: USB, RS232, RS485, WiFi, and dry contact; reserved port for BMS (RS485\/CAN).\u003c\/li\u003e\n  \u003cli\u003eAdvanced functions: “battery independent”, equalization (lead-acid), internal datalog, and anti-dust kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher solar production\u003c\/strong\u003e thanks to the high-voltage MPPT, ideal for long runs and variable climates.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified installation\u003c\/strong\u003e by integrating inverter, charger, and controller in a single compact unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eService continuity\u003c\/strong\u003e with fast switching and the ability to operate without a battery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntelligent management\u003c\/strong\u003e via WiFi and touch LCD to configure priorities (solar\/grid\/battery) and log events.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e with anti-dust kit, controlled ventilation, and comprehensive electrical protections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuously used off-grid homes, farms, country houses, small workshops, telecom, or businesses in areas with unstable grid. Suitable as a main 24 V system or as backup with generator, when efficiency, control, and ease of PV expansion are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e3600 VA \/ 3600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e7200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e15 ms (PC) \/ 20 ms (Home)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e90–93 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (float 27 V; protection 33 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eMPPT 120–450 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV power\u003c\/td\u003e\n\u003ctd\u003e4000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax solar current\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTotal max charge\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e230 VAC; 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ WiFi \/ dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4.3” touch LCD + RGB LED ring\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e115 × 300 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C; 5–95 % RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 24 V battery banks (AGM\/GEL lead-acid and lithium with suitable parameters), PV array within 120–450 V (Voc ≤ 500 V), and 230 VAC grid\/generator. Recommended accessories: DC\/AC protections, fuses and fuse holders for battery, disconnectors, solar cabling, structures, and monitoring kits.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM IV 3600-24 3600W 24V MPPT Off-Grid Inverter\u003c\/strong\u003e offers a clear value proposition: more energy, more control, and maximum flexibility for your 24 V off-grid installation.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243460949,"sku":"VOLTINV005","price":384.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-VMIII-1_f9a6c190-3409-4122-836b-c71844ee3295.png?v=1762628617"},{"product_id":"inversor-voltronic-vm-iv-5600-48-5600w-48v-mppt","title":"Off-Grid Inverter Voltronic Axpert VM IV 5600-48 5600W 48V MPPT","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM IV 5600-48 5600W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e is designed for off-grid installations that require higher continuous power and greater photovoltaic capacity. It integrates a pure sine wave inverter of 5600 W, charger, and \u003cstrong\u003eMPPT solar controller 120–450 V \/ 120 A\u003c\/strong\u003e, supporting up to \u003cstrong\u003e6000 W PV\u003c\/strong\u003e with a maximum Voc of 500 V. \u003cstrong\u003eWiFi\u003c\/strong\u003e connectivity enables monitoring via APP, while the \u003cstrong\u003e4.3” touch LCD display\u003c\/strong\u003e and \u003cstrong\u003eRGB LED ring\u003c\/strong\u003e provide a modern user experience. Its “battery independent” design allows operation and load supply from PV\/grid even without a battery, adding operational flexibility for continuous work scenarios.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 5600 VA \/ 5600 W with \u003cstrong\u003epure sine wave\u003c\/strong\u003e at 230 VAC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPPT 120–450 V (max Voc 500 V) and 120 A\u003c\/strong\u003e; allowable PV power 6000 W.\u003c\/li\u003e\n  \u003cli\u003eAC input with selectable range: 170–280 VAC (PC) \/ 90–280 VAC (Home).\u003c\/li\u003e\n  \u003cli\u003eFast transfer with a peak of \u003cstrong\u003e11,200 VA\u003c\/strong\u003e for motor starts and dynamic loads.\u003c\/li\u003e\n  \u003cli\u003eConnectivity: USB, RS232, RS485, WiFi, and dry contact; reserved port for BMS.\u003c\/li\u003e\n  \u003cli\u003eMaintenance functions: equalization (lead-acid), event log, and anti-dust kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior power\u003c\/strong\u003e for continuously used homes, workshops, or small businesses with medium-high demands.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreater solar capture\u003c\/strong\u003e by allowing high-voltage strings and up to 6 kW of PV array.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational flexibility\u003c\/strong\u003e with batteryless mode and energy priority configuration (solar\/grid\/battery).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection and stability\u003c\/strong\u003e with pure sine wave, fast switching, and extensive internal protections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced management\u003c\/strong\u003e via APP, touch LCD, and internal datalog for diagnostics and fine adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for larger off-grid residences, light agro-industry, workshops, remote offices, and small commercial installations requiring stable 230 VAC from a 48 V battery bank with high solar contribution and centralized control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e5600 VA \/ 5600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave (230 VAC ±5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e11,200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e15 ms (PC) \/ 20 ms (Home)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e90–93 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC (float 54 V; protection 63 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eMPPT 120–450 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV power\u003c\/td\u003e\n\u003ctd\u003e6000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax solar current\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax AC charger\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTotal max charge\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e230 VAC; 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232 \/ RS485 \/ WiFi \/ dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4.3” touch LCD + RGB LED ring\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e115 × 300 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C; 5–95 % RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 48 V battery banks (AGM\/GEL lead-acid and lithium with suitable parameters), PV array within 120–450 V (Voc ≤ 500 V), and 230 VAC grid\/generator. Recommended accessories: DC\/AC protections, battery fuses and fuse holders, disconnectors, solar cabling, and structures.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VM IV 5600-48 5600W 48V MPPT Off-Grid Inverter\u003c\/strong\u003e is a powerful and flexible platform for demanding off-grid projects seeking robustness, high performance, and professional control.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243559253,"sku":"VOLTINV006","price":437.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-AXPERT-VMIII-1_10e2652b-423a-425b-acda-39dcf57785e6.png?v=1762628621"},{"product_id":"inversor-voltronic-vp-1000-12-1000w-12v-pwm","title":"Off-Grid Inverter Voltronic Axpert VP 1000-12 1000W 12V PWM","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VP 1000-12 1000W 12V PWM Off-Grid Inverter\u003c\/strong\u003e is an all-in-one device for compact off-grid systems that integrates a pure sine wave inverter, battery charger, and \u003cstrong\u003e50 A PWM solar controller\u003c\/strong\u003e. With a nominal power of 1000 W and stable output technology at 230 VAC, it offers a reliable solution to power basic loads with 12 V batteries, optimizing available solar energy and allowing you to prioritize the input source according to your needs.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power: 1000 VA \/ 1000 W with pure sine wave.\u003c\/li\u003e\n  \u003cli\u003eIntegrated solar controller: PWM 50 A; allowable PV power 600 W, max Voc 55 V.\u003c\/li\u003e\n  \u003cli\u003eBattery voltage: 12 VDC; AC charger up to 20 A; maximum combined charging current 50 A.\u003c\/li\u003e\n  \u003cli\u003ePeak efficiency: 90–93% with regulation at 230 VAC ± 5%.\u003c\/li\u003e\n  \u003cli\u003eFast switching: 10 ms (PC) \/ 20 ms (appliances); peak power 2000 VA.\u003c\/li\u003e\n  \u003cli\u003eUSB\/RS232 communications and functions: cold start, configurable solar\/AC priority, and protection against overload and short circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEconomical and reliable solution for off-grid self-consumption with light loads.\u003c\/li\u003e\n  \u003cli\u003ePure sine wave that protects sensitive equipment (electronics, small pumps, LED lighting).\u003c\/li\u003e\n  \u003cli\u003eFlexible configuration: choose whether to prioritize solar energy or grid\/generator to extend battery life.\u003c\/li\u003e\n  \u003cli\u003eSimple installation: all integrated, less wiring, and reduced commissioning time.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance with monitoring via USB\/RS232 and parameters visible on screen.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for field cabins, small boats, camper vans, basic telecommunications, low-power pumping, or occasional-use homes where stable 230 VAC is required from a 12 V battery.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal power\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 1000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230 VAC ±5% (pure sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSwitching\u003c\/td\u003e\n\u003ctd\u003e10 ms (PC) \/ 20 ms (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e90–93%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFloat \/ Overload protection\u003c\/td\u003e\n\u003ctd\u003e13.5 V \/ 16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV controller type\u003c\/td\u003e\n\u003ctd\u003eIntegrated PWM 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV power\u003c\/td\u003e\n\u003ctd\u003e600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e55 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPP range\u003c\/td\u003e\n\u003ctd\u003eNot applicable (PWM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e20 A (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax combined charging\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e88 × 225 × 320 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 12 V batteries, 230 V AC grid, and generator. Recommended accessories: DC protections for low-voltage strings, AC output protections, solar cabling, fuses\/fuse holders, panel mounting structures, and monitoring via USB\/RS232. If internal products are available, they can be linked here.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VP 1000-12 1000W 12V PWM Off-Grid Inverter\u003c\/strong\u003e provides reliability, simplicity, and cost-effectiveness to start your off-grid solar system with guaranteed pure sine wave and integrated solar management.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243657557,"sku":"VOLTINV001","price":180.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-VP-12-1000.png?v=1762628626"},{"product_id":"inversor-voltronic-vp-3000-24-3000w-24v-pwm","title":"Off-Grid Inverter Voltronic Axpert VP 3000-24 3000W 24V PWM","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic Axpert VP 3000-24 3000W 24V PWM Off-Grid Inverter\u003c\/strong\u003e integrates a 3000 W inverter, battery charger, and \u003cstrong\u003e50 A PWM solar charge controller\u003c\/strong\u003e, becoming the heart of 24 V installations seeking stability, performance, and control. It delivers 230 VAC pure sine wave output, fast switching, and the ability to prioritize solar or grid\/generator power to optimize your battery cycle.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power: 3000 VA \/ 3000 W with pure sine wave output.\u003c\/li\u003e\n  \u003cli\u003eIntegrated solar controller: PWM 50 A; PV power up to 1200 W and max Voc 80 V.\u003c\/li\u003e\n  \u003cli\u003e24 VDC system; AC charger 25 A and maximum combined charging current 70 A.\u003c\/li\u003e\n  \u003cli\u003ePeak efficiency: 90–93%; output regulation 230 VAC ± 5%.\u003c\/li\u003e\n  \u003cli\u003eSwitching: 10 ms (PC) \/ 20 ms (appliances); peak power 6000 VA.\u003c\/li\u003e\n  \u003cli\u003eUSB\/RS232, cold start, integrated protections, and configurable solar\/AC priority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGreater capacity for off-grid homes, light workshops, or small businesses with medium consumption.\u003c\/li\u003e\n  \u003cli\u003eStable pure sine wave for sensitive electronics and small motors.\u003c\/li\u003e\n  \u003cli\u003eFlexible energy management that extends battery lifespan.\u003c\/li\u003e\n  \u003cli\u003e“All-in-one” architecture that simplifies design, installation, and maintenance.\u003c\/li\u003e\n  \u003cli\u003eScalable: allows PV array expansion up to 1200 W and growth according to demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for off-grid homes, farms, remote offices, telecom, and professional applications requiring stable 230 VAC from a 24 V battery bank. Suitable as a main system or for backup with a generator.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230 VAC ±5% (pure sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSwitching\u003c\/td\u003e\n\u003ctd\u003e10 ms (PC) \/ 20 ms (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePeak efficiency\u003c\/td\u003e\n\u003ctd\u003e90–93%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFloat \/ Overload protection\u003c\/td\u003e\n\u003ctd\u003e27 V \/ 31 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV charge controller type\u003c\/td\u003e\n\u003ctd\u003eIntegrated PWM 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV power\u003c\/td\u003e\n\u003ctd\u003e1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax PV Voc\u003c\/td\u003e\n\u003ctd\u003e80 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMPP range\u003c\/td\u003e\n\u003ctd\u003eNot applicable (PWM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC charger\u003c\/td\u003e\n\u003ctd\u003e25 A (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax combined charging\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (DxWxH)\u003c\/td\u003e\n\u003ctd\u003e100 × 300 × 440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e–10 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eDirect compatibility: 24 V battery banks, 230 V AC grid, and generator. Recommended accessories: DC\/AC protections suitable for the PV range and output power, solar and battery cabling, panel mounting structures, and monitoring tools via USB\/RS232. If there are internal URLs, link them here.\u003c\/p\u003e\n\n\u003cp\u003eWith the \u003cstrong\u003eVoltronic Axpert VP 3000-24 3000W 24V PWM Off-Grid Inverter\u003c\/strong\u003e you get a robust and versatile platform for 24 V off-grid systems, with integrated solar management and excellent value for money.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243788629,"sku":"VOLTINV002","price":238.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-VP-12-1000_b0bca2b0-ff95-4f30-89bb-89e7f140288e.png?v=1762628627"},{"product_id":"inversor-voltronic-infinisolar-plus-5kw-5000w-48v","title":"Voltronic InfiniSolar Plus 5kW 5000W 48V Hybrid Inverter","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic InfiniSolar Plus 5kW 5000W 48V Hybrid Inverter\u003c\/strong\u003e is a powerful and versatile hybrid system that combines grid connection, battery storage, and automatic backup. It incorporates \u003cstrong\u003etwo independent MPPTs\u003c\/strong\u003e with a wide operating range of \u003cstrong\u003e250–850 V\u003c\/strong\u003e and up to 10 kW of allowable PV power, enabling long strings, better solar utilization, and reduced cable losses. Its control logic allows prioritization of PV, battery, or grid according to schedules and tariffs; at night or during an outage, it switches to battery mode to keep the installation running without interruption.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal power: 5,000 W (230 VAC), pure sine wave, power factor \u0026gt; 0.99.\u003c\/li\u003e\n  \u003cli\u003ePV input: 2× MPPT 250–850 V; \u003cstrong\u003eMax Voc 900 V\u003c\/strong\u003e; current 2×10 A; allowable solar power 10 kW.\u003c\/li\u003e\n  \u003cli\u003eHybrid operation: grid-tie, off-grid, and grid-tie with backup; programmable source priority.\u003c\/li\u003e\n  \u003cli\u003eAdjustable 48 V charger 5–100 A (60 A default) to suit different battery banks.\u003c\/li\u003e\n  \u003cli\u003eMaximum DC\/AC efficiency up to 96% (European 95%); possibility of \u003cstrong\u003eparallel operation up to 6 units\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eProfessional interfaces: RS-232\/USB and dry contact; optional smart slot for SNMP\/Modbus\/AS-400.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher PV production\u003c\/strong\u003e with dual high-voltage MPPT and 10 kW allowable solar field.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResilience\u003c\/strong\u003e against grid failures with battery backup and fast switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSavings\u003c\/strong\u003e by prioritizing self-consumption and storing surplus for expensive or nighttime periods.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eScalability\u003c\/strong\u003e in power and phases through parallel operation (up to 6 units).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegration\u003c\/strong\u003e into monitoring systems and external BMS via standard interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eHomes and businesses with advanced self-consumption, residential projects with 48 V batteries, hybrid installations with generator, and scenarios requiring service continuity and intelligent energy management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e5,000 W (230 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input\u003c\/td\u003e\n\u003ctd\u003e2× MPPT 250–850 V; Max Voc 900 V; 2×10 A; 10 kW PV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eGrid-tie \/ Off-grid \/ Grid-tie with backup\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency (DC\/AC)\u003c\/td\u003e\n\u003ctd\u003eMax 96%; European 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e48 V; charge 5–100 A (60 A default)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e170–280 VAC; start 120–140 VAC; auto-restart 180 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput in battery mode\u003c\/td\u003e\n\u003ctd\u003e230 VAC, pure sine wave; efficiency up to 93%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eParallel\u003c\/td\u003e\n\u003ctd\u003eUp to 6 units\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eRS-232\/USB, dry contact; SNMP\/Modbus\/AS-400 slot (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\/Weight\u003c\/td\u003e\n\u003ctd\u003e≈167.2 × 500 × 622 mm; 40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e−10 °C to 55 °C; RH 0–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eVDE-AR-N 4105, VDE 0126-1-1 (depending on version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 48 V banks (AGM\/GEL and lithium with appropriate parameters), 230 VAC grid, and PV fields within 250–850 V (Voc ≤ 900 V). Recommended accessories: DC\/AC protections, battery fuses and fuse holders, disconnectors, 1000\/1500 V solar cable, structures, and SNMP\/Modbus cards.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic InfiniSolar Plus 5kW 5000W 48V Hybrid Inverter\u003c\/strong\u003e combines power, efficiency, and versatility for battery self-consumption projects that require a robust and scalable platform.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243886933,"sku":"VOLTINV014","price":1956.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-INFINISOLAR-PLUS-5KW.png?v=1762628630"},{"product_id":"inversor-voltronic-infinisolar-plus-ii-3kw-3000w-48v","title":"Voltronic InfiniSolar Plus II 3kW 3000W 48V Hybrid Inverter","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic InfiniSolar Plus II 3kW 3000W 48V Hybrid Inverter\u003c\/strong\u003e is a next-generation hybrid inverter that integrates grid-tie conversion, 48 V battery storage, and automatic backup to ensure supply continuity. With its \u003cstrong\u003eMPPT 250–450 V\u003c\/strong\u003e tracker and a PV input capacity of up to 4.5 kW, it allows for high-voltage strings, reduced cable cross-section, and superior performance compared to low-voltage controllers. Its electronics intelligently manage the priority between PV, battery, and grid according to usage profiles, so you can prioritize self-consumption, store surplus for nighttime, and have \u003cstrong\u003ebackup\u003c\/strong\u003e available when the grid fails.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNominal output power: 3,000 W (230 VAC), pure sine wave.\u003c\/li\u003e\n  \u003cli\u003ePV input: MPPT 250–450 V; \u003cstrong\u003eMax Voc 500 V\u003c\/strong\u003e; allowable solar power 4.5 kW; 1 MPPT (18 A).\u003c\/li\u003e\n  \u003cli\u003eProgrammable modes: grid-tie, off-grid, and grid-tie with backup; configurable PV\/Battery\/Grid priority.\u003c\/li\u003e\n  \u003cli\u003e48 V battery charger: 5–60 A adjustable (25 A default) with algorithms for different battery types.\u003c\/li\u003e\n  \u003cli\u003eMaximum DC\/AC efficiency up to 96% (European 95%); software monitoring via USB\/RS-232 and optional smart slot.\u003c\/li\u003e\n  \u003cli\u003eAC input range for charging\/grid: 170–280 VAC; start\/auto-restart 120–140\/180 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue self-consumption\u003c\/strong\u003e: prioritizes solar and batteries to reduce electricity bills and grid dependence.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic backup\u003c\/strong\u003e: continuity during outages thanks to battery mode and fast switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePV optimization\u003c\/strong\u003e: high-voltage strings (up to 500 V open circuit) with lower cable losses and higher efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexibility\u003c\/strong\u003e: adjust charging current, operating windows, and priority sources according to the season.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional control\u003c\/strong\u003e: multiple communications, real-time logging, and integration capability with management systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eGrid-connected homes seeking to maximize self-consumption with 48 V batteries while maintaining backup; small businesses, offices, and residential projects requiring efficiency, stability, and control in a single device.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e3,000 W (230 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePV input\u003c\/td\u003e\n\u003ctd\u003e1× MPPT 250–450 V; Max Voc 500 V; 18 A; 4.5 kW PV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eGrid-tie \/ Off-grid \/ Grid-tie with backup\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEfficiency (DC\/AC)\u003c\/td\u003e\n\u003ctd\u003eMax. 96%; European 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e48 V; charging 5–60 A (25 A default)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC input\u003c\/td\u003e\n\u003ctd\u003e170–280 VAC; start 120–140 VAC; auto-restart 180 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput in battery mode\u003c\/td\u003e\n\u003ctd\u003e230 VAC, pure sine; efficiency up to 93%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB, RS-232; smart slot for SNMP\/Modbus\/AS-400 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\/Weight\u003c\/td\u003e\n\u003ctd\u003e≈204.2 × 460 × 600 mm; 29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e−10 °C to 55 °C; RH 0–90% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eVDE-AR-N 4105, VDE 0126-1-1, AS4777\/AS-NZS3100 (depending on version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 48 V battery banks (AGM\/GEL lead-acid and lithium with suitable parameters), 230 VAC grid, and PV arrays within 250–450 V (Voc ≤ 500 V). Recommended accessories: DC\/AC protections, battery fuses, disconnectors, PV cabling 1000\/1500 V, panel structures, and SNMP\/Modbus gateways.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVoltronic InfiniSolar Plus II 3kW 3000W 48V Hybrid Inverter\u003c\/strong\u003e combines efficiency, backup, and intelligent control to drive residential self-consumption with maximum reliability.\u003c\/p\u003e","brand":"Voltronic","offers":[{"title":"Default Title","offer_id":51503243985237,"sku":"VOLTINV013","price":984.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/VOLTRONIC-INFINISOLAR-PLUS-II-3KW.png?v=1762628633"}],"url":"https:\/\/aurensol.net\/en\/collections\/inversores-aislada-cargador-mppt.oembed","provider":"Aurensol","version":"1.0","type":"link"}