{"title":"GAVE","description":"\u003ch2\u003eWhat is the GAVE collection in photovoltaic protection?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE\u003c\/strong\u003e collection brings together boxes and protection components specifically designed for solar installations in \u003cstrong\u003eAC\u003c\/strong\u003e and \u003cstrong\u003eDC\u003c\/strong\u003e. It includes single-phase and three-phase AC output panels with circuit breaker and residual current device, as well as DC boxes for photovoltaic strings with disconnection and surge protection, ready to operate up to 1000 V DC depending on the model.\u003c\/p\u003e\n\n\u003ch3\u003eAdvantages and limitations\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePre-configured solutions that simplify design and reduce assembly times.\u003c\/li\u003e\n  \u003cli\u003eConfigurations for single or multiple \u003cem\u003estrings\u003c\/em\u003e, single-phase or three-phase, and different current ranges.\u003c\/li\u003e\n  \u003cli\u003eDC protections with disconnection, fuses\/fuse holders, and SPD suitable for the PV range.\u003c\/li\u003e\n  \u003cli\u003eAC protections with MCB and RCD (30 mA) according to inverter power and grid type.\u003c\/li\u003e\n  \u003cli\u003eLimitations: it is essential to verify the \u003cstrong\u003emaximum Voc\u003c\/strong\u003e of the PV array, the \u003cstrong\u003eIsc\u003c\/strong\u003e per string, and the \u003cstrong\u003enominal current\u003c\/strong\u003e in AC to choose the correct panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential self-consumption (single-phase inverters up to ~10 kW) with dedicated AC panel.\u003c\/li\u003e\n  \u003cli\u003eSME\/industrial (three-phase) with disconnection and coordinated SPD requirements.\u003c\/li\u003e\n  \u003cli\u003eDC protection for PV strings (1 to 4 MPPT \/ 1–4 \u003cem\u003estrings\u003c\/em\u003e per input, depending on the box) up to 1000 V DC.\u003c\/li\u003e\n  \u003cli\u003eIntegration with \u003ca href=\"\/en\/collections\/inversores-solares-monofasicos\"\u003esingle-phase inverters\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/inversores-solares-trifasicos\"\u003ethree-phase inverters\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to choose your GAVE box\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC side\u003c\/strong\u003e: inverter power, number of phases (1F\/3F), and nominal current (typically 16–63 A). Select the \u003cstrong\u003eRCD 30 mA\u003c\/strong\u003e and the MCB according to the required current and curve.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC side\u003c\/strong\u003e: number of \u003cem\u003estrings\/MPPT\u003c\/em\u003e, \u003cstrong\u003emaximum Voc\u003c\/strong\u003e of the generator, \u003cstrong\u003eIsc\u003c\/strong\u003e per string, and need for Type II SPD. Choose appropriate disconnection and fuses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: IP rating and installation space. Check cable gland entries and cable cross-section.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIndicative specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC panels\u003c\/td\u003e\n\u003ctd\u003eSingle-phase 16–40 A \/ Three-phase 16–63 A with RCD 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDC panels\u003c\/td\u003e\n\u003ctd\u003e1–4 MPPT \/ 1–4 strings, up to 1000 V DC (depending on model)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDC protection\u003c\/td\u003e\n\u003ctd\u003eDisconnector, fuse per pole, and Type II photovoltaic SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAC protection\u003c\/td\u003e\n\u003ctd\u003eAppropriate curve MCB and 30 mA residual current device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003ePre-wired, identified terminals, and cable glands included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eValid for most \u003ca href=\"\/en\/collections\/inversores-solares-monofasicos\"\u003e1F inverters\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/inversores-solares-trifasicos\"\u003e3F inverters\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eBest practices\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSize strings with thermal margin: Voc at minimum temperature \u0026lt; maximum voltage of the DC panel.\u003c\/li\u003e\n  \u003cli\u003eCoordinate SPD in DC and AC with the earthing scheme and cable distances.\u003c\/li\u003e\n  \u003cli\u003eEnsure visible disconnection in DC near the inverter and accessibility of the AC panel.\u003c\/li\u003e\n  \u003cli\u003eClear labeling of MPPT\/strings and insulation and polarity tests before energizing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuick comparisons\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-phase AC\u003c\/strong\u003e: homes and inverters up to ~10 kW; simple and compact installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThree-phase AC\u003c\/strong\u003e: commercial\/industrial, higher currents, and load distribution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC 1 MPPT \/ 1–2 strings\u003c\/strong\u003e: small generators with a single tracker.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC 2–4 MPPT \/ 2–4 strings\u003c\/strong\u003e: larger generators or rooftops with mixed orientations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated collections\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en\/collections\/protecciones-electricas-ca\"\u003eAC Electrical Protections\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en\/collections\/protecciones-electricas-cc\"\u003eDC Electrical Protections\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en\/collections\/kits-protecciones-ca\"\u003eAC Protection Kits\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en\/collections\/kits-protecciones-cc\"\u003eDC Protection Kits\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWith \u003cstrong\u003eGAVE\u003c\/strong\u003e you ensure regulatory safety, service continuity, and fast, professional installation in residential, commercial, and industrial photovoltaic systems.\u003c\/p\u003e","products":[{"product_id":"caja-protecciones-ac-gave-acm-e1c-enphase-monofasico","title":"AC Protection Box Enphase Single-phase GAVE ACM-E1C 20A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEnphase Single-Phase AC Protection Box GAVE ACM-E1C 20A 30mA\u003c\/strong\u003e is a modular panel designed to integrate, in a single point, the protections, isolation, and measurement of Enphase IQ systems at 230 V. It optimizes installation time, ensures regulatory compliance, and comes pre-installed for Q-Relay, IQ Gateway\/Envoy, and current transformers (CT), providing a clean and professional design with Class II and IK08 enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase configuration for 1 AC PV circuit with capacity up to 20 A (≈ 4.6 kVA at 230 V).\u003c\/li\u003e\n  \u003cli\u003eMCB curve C 2P 20 A with 6 kA breaking capacity (EN 60898-1).\u003c\/li\u003e\n  \u003cli\u003eType A RCD 30 mA 2P, immune to unwanted tripping (EN 61008-1).\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) for grid interface protection.\u003c\/li\u003e\n  \u003cli\u003ePrepared for \u003cem\u003eEnphase ecosystem\u003c\/em\u003e: Q-Relay 1F, IQ Gateway\/Envoy (Metered), and production\/consumption CTs.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure with double insulation Class II and IK08 for high mechanical resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and tidier installation by concentrating protections, measurement, and communications in a single panel.\u003c\/li\u003e\n  \u003cli\u003eEnhanced electrical safety with 30 mA RCD and Type II SPD, reducing risks from indirect contact and overvoltages.\u003c\/li\u003e\n  \u003cli\u003eReady for export limitation and advanced monitoring via IQ Gateway\/Envoy with bidirectional CTs.\u003c\/li\u003e\n  \u003cli\u003eFacilitates compliance with grid connection regulations and distributor requirements (disconnection via Q-Relay).\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: front access to protections and terminals, clear labeling, and streamlined internal wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for residential self-consumption and small single-phase commercial applications with Enphase IQ microinverters (IQ7\/IQ8 series), both with feed-in and with export limitation. Also suitable for setups with AC-coupled batteries (e.g., Enphase IQ Battery 5P), where it serves as a protection and measurement point on the AC side.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eUp to ≈ 4.6 kVA (20 A at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e230 V~ 50 Hz (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eModular enclosure Class II, polycarbonate, IK08\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMagnetothermal protection\u003c\/td\u003e\n\u003ctd\u003e2P 20 A, curve C, 6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A, 30 mA, 2P (immunized)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 PV AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eQ-Relay 1F, IQ Gateway\/Envoy (Metered), production\/consumption CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with the Enphase IQ single-phase ecosystem: IQ7\/IQ8 (EU\/INT) microinverters, IQ Gateway\/Envoy with metering, Q-Relay 1F, and Enphase production and consumption current transformers. Also integrable in systems with Enphase IQ Battery 5P (AC coupling).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEnphase AC Protection Box Single-Phase GAVE ACM-E1C 20A 30mA\u003c\/strong\u003e is the professional solution for centralizing protections, metering, and communications in Enphase installations, increasing safety, organization, and efficiency from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502777041237,"sku":"GAVEPRO011","price":742.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACM-E1C.png?v=1762626043"},{"product_id":"caja-protecciones-ac-gave-act-e1c-enphase-trifasico","title":"AC Protection Box Enphase Three-phase GAVE ACT-E1C 20A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEnphase Three-Phase AC Protection Box GAVE ACT-E1C 20A 30mA\u003c\/strong\u003e is a 3F+N connection and safety panel that integrates, in a single Class II enclosure, all the key functions of a three-phase Enphase IQ system: isolation, circuit breaker and residual current protection, overvoltage protection, and the environment for three-phase Q-Relay, IQ Gateway\/Envoy (metered), and current transformers (CT) for production and consumption. Designed to streamline installation and ensure regulatory compliance, it offers a professional and robust finish (IK08) suitable for demanding locations.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3F+N configuration for 1 AC circuit with capacity up to 20 A per phase (≈ 13.9 kVA at 3×400\/230 V).\u003c\/li\u003e\n  \u003cli\u003e4P 20 A circuit breaker, curve C, 6 kA (EN 60898-1) for protection against short circuits and overloads.\u003c\/li\u003e\n  \u003cli\u003e4P Type A 30 mA residual current device with immunity to unwanted tripping, compatible with electronic loads.\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) for grid interface protection.\u003c\/li\u003e\n  \u003cli\u003ePlug \u0026 play preparation for the Enphase ecosystem: Q-Relay 3F, IQ Gateway\/Envoy (Metered), and split-core CT.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure, double insulation Class II, IK08 resistance, and field-ready design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSaves time and reduces errors by concentrating protections, measurement, and communications in a single panel.\u003c\/li\u003e\n  \u003cli\u003eMaximum safety with 30 mA RCD and Type II SPD that reduce risks from indirect contact and overvoltages.\u003c\/li\u003e\n  \u003cli\u003eReady for advanced monitoring, power control, and export limitation via Envoy (metered).\u003c\/li\u003e\n  \u003cli\u003eFacilitates compliance with distributor requirements thanks to the three-phase Q-Relay disconnection.\u003c\/li\u003e\n  \u003cli\u003eClean and maintainable installation: streamlined wiring, accessible terminals, and clear labeling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eOriented towards residential and small commercial (C\u0026I) three-phase self-consumption with Enphase HMT\/MIT microinverters or Enphase three-phase strings in Europe, both in installations with grid export and those requiring export limitation. Also suitable for setups with AC-coupled batteries (e.g., Enphase IQ Battery 5P) where the panel acts as the central point for protection and measurement on the AC side.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eUp to ≈ 13.9 kVA (20 A\/phase at 3×400\/230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (three-phase 3F+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eModular polycarbonate enclosure, Class II, IK08\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMagnetothermal protection\u003c\/td\u003e\n\u003ctd\u003e4P 20 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4P · immunized (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 three-phase AC PV circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 586 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with the Enphase IQ three-phase ecosystem (EU\/INT): HMT\/MIT microinverters, IQ Gateway\/Envoy with metering, Q-Relay 3F, and production\/consumption CTs. Integrable in systems with Enphase IQ Battery 5P in three-phase AC coupling.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEnphase AC Protection Box Three-phase GAVE ACT-E1C 20A 30mA\u003c\/strong\u003e is the professional option for centralizing protection, measurement, and control in Enphase 3F+N installations, improving safety, organization, and efficiency from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502777205077,"sku":"GAVEPRO012","price":779.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-E1C.png?v=1762626044"},{"product_id":"caja-protecciones-ac-gave-acm16sda-3-7kw-16a-30ma","title":"AC Protection Box Single-phase GAVE ACM16SDA 3.7kW 16A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACM16SDA 3.7kW 16A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is a compact panel that integrates all critical safety functions for an AC branch of up to 3.7 kW in a single enclosure. It combines circuit breaker protection, high-sensitivity residual current protection, and transient overvoltage limitation (Type II SPD), offering a professional, clean, and quick-to-install solution for connecting single-phase inverters or microinverters to the main panel of a home or small business.\u003c\/p\u003e\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase 230 V, 1 dedicated AC circuit, continuous capacity up to 16 A (≈ 3.68 kVA\/kW).\u003c\/li\u003e\n  \u003cli\u003e2P 16 A MCB, curve C, breaking capacity 6 kA for protection against overloads and short circuits.\u003c\/li\u003e\n  \u003cli\u003eType A RCD 30 mA, sensitivity for personal protection and immunity against unwanted tripping.\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) to safeguard the grid interface.\u003c\/li\u003e\n  \u003cli\u003eClass II enclosure (double insulation) in polycarbonate, suitable for indoor or protected outdoor use, with DIN rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster installation: “turnkey” panel that centralizes protections and sectioning of the PV\/AC branch.\u003c\/li\u003e\n  \u003cli\u003eAdvanced safety: 30 mA RCD for personal protection and Type II SPD to mitigate grid transients.\u003c\/li\u003e\n  \u003cli\u003eFacilitated regulatory compliance: selection of switchgear and coordination of protections in accordance with best practices.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: front access to switches and terminals, clear labeling, and streamlined wiring.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust design: ideal where space is limited without sacrificing selectivity with the main panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for residential single-phase self-consumption and small commercial applications with inverters up to 3.7 kW, microinverter branches grouped at 16 A, and systems with AC-coupled batteries whose branch does not exceed the nominal current. Acts as a safe interconnection point between generation\/backup and the main panel, both in installations with grid export and in configurations with export limitation.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 3.7 kW (16 A at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e230 V~ 50 Hz (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eClass II modular enclosure (double insulation) with DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMiniature circuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e2P 16 A · curve C · 6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 231 × 238 × 118 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with single-phase inverters up to 3.7 kW and strings of microinverters whose aggregate does not exceed 16 A at 230 V. Integrable with monitoring systems via external CTs and can be coordinated with upstream protections (main circuit breaker, main residual current device, and main SPD) according to the project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGAVE ACM16SDA 3.7kW 16A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is the professional choice for centralizing safety, order, and reliability in the AC branch of your installation, optimizing assembly time and the protection of equipment and people.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502777270613,"sku":"GAVEPRO001","price":119.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACM-SDA.png?v=1762626045"},{"product_id":"caja-protecciones-ac-gave-acm25sda-5-8kw-25a-30ma","title":"AC Protections Box Single-phase GAVE ACM25SDA 5.8kW 25A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACM25SDA 5.8kW 25A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is a compact, professional panel that integrates all critical safety functions for an AC circuit up to 5.8 kW in a single enclosure. It combines circuit breaker protection, high-sensitivity residual current protection, and transient overvoltage limitation (Type II SPD), providing a reliable interconnection point between AC generation\/backup and the main distribution board. Its modular design, Class II double insulation, and mechanical robustness allow for quick, organized, and compliant installation, reducing installation time and future maintenance interventions.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase 230 V, 50 Hz, 1 dedicated AC circuit with continuous capacity up to 25 A (≈ 5.8 kVA\/kW).\u003c\/li\u003e\n  \u003cli\u003e2P 25 A MCB, curve C, breaking capacity 6 kA (EN 60898-1) for overloads and short circuits.\u003c\/li\u003e\n  \u003cli\u003eType A RCD 30 mA, 2-pole, sensitivity for personal protection with immunity to unwanted tripping.\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) to protect equipment against grid transients.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure with double insulation Class II, DIN rail, and streamlined internal wiring.\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions (approx. 231 × 238 × 118 mm) that facilitate integration in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eQuick installation: turnkey panel that centralizes protections, isolation, and connection of the PV\/AC branch.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety: 30 mA RCD to protect people and Type II SPD to mitigate transient overvoltages.\u003c\/li\u003e\n  \u003cli\u003eFacilitated technical compliance: switchgear selected according to best practices and protection coordination.\u003c\/li\u003e\n  \u003cli\u003eSimple and organized maintenance: front access to switches and terminals, clear labeling, and reduced risk of errors.\u003c\/li\u003e\n  \u003cli\u003eVersatility: suitable for single-phase inverters of ~4–6 kW, microinverter strings, and AC backup systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for single-phase residential self-consumption and small commercial applications with inverters up to 5.8 kW or strings of microinverters whose combined output does not exceed 25 A. It is also suitable for hybrid systems with AC-coupled batteries where the line current remains within the nominal limit. Serves as a safe and compliant interconnection point between the AC generator\/backup and the main distribution board, both in installations with grid export and those with export limitation.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 5.8 kW (25 A at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e230 V~ · 50 Hz (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eModular enclosure Class II (double insulation) with DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMiniature circuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e2P 25 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated PV\/AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 231 × 238 × 118 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with single-phase inverters of ~4–6 kW and with strings of microinverters (Enphase, Hoymiles, etc.) as long as the total does not exceed 25 A at 230 V. Integrable with monitoring systems via external current transformers and can be coordinated with upstream protections (main circuit breaker, main residual current device, and main SPD) according to the project.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACM25SDA 5.8kW 25A 30mA Single-phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, order, and reliability in the AC branch of your installation, optimizing assembly time and the protection of equipment and people.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502777598293,"sku":"GAVEPRO002","price":144.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACM-SDA_dbc97ca7-1552-4a95-93f2-53276bc9811f.png?v=1762626048"},{"product_id":"caja-protecciones-ac-gave-acm32sda-7-4kw-32a-30ma","title":"AC Protections Box Single-phase GAVE ACM32SDA 7.4kW 32A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACM32SDA 7.4kW 32A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is a turnkey modular panel designed to concentrate the critical safety and connection functions of the AC branch in self-consumption installations at a single point. Its design integrates circuit breaker protection, high-sensitivity residual current protection, and transient overvoltage limitation (Type II SPD) within a double-insulated polycarbonate enclosure (Class II) with high mechanical resistance (IK7), which speeds up assembly, organizes the installation, and facilitates compliance with good electrical practices.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase 230 V·50 Hz, 1 dedicated AC circuit with continuous capacity up to 32 A (≈ 7.4 kVA\/kW).\u003c\/li\u003e\n  \u003cli\u003e2P 32 A circuit breaker (MCB), curve C, 6 kA breaking capacity for overload and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003eType A residual current device (RCD) 30 mA, 2 poles, with immunity to unwanted tripping.\u003c\/li\u003e\n  \u003cli\u003eType II SPD surge protection (In 20 kA, Imax 40 kA, Up 1.5 kV) with associated fuse.\u003c\/li\u003e\n  \u003cli\u003eClass II polycarbonate enclosure (double insulation), IK7 rating, suitable for indoor or protected outdoor use.\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions that simplify integration into confined spaces within the electrical room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and cleaner installation: centralizes disconnection, protection, and connection of the PV\/AC branch.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety: 30 mA RCD for personal protection and Type II SPD to mitigate network transients.\u003c\/li\u003e\n  \u003cli\u003eFacilitates technical compliance: selection of switchgear and coordination of protections in accordance with best practices.\u003c\/li\u003e\n  \u003cli\u003eEasy maintenance: front access to devices and terminals, clear labeling, and streamlined wiring.\u003c\/li\u003e\n  \u003cli\u003eVersatility: suitable for single-phase inverters of ~5–7.5 kW or microinverter strings whose aggregate does not exceed 32 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for single-phase residential self-consumption and small tertiary applications with a single AC generation\/backup circuit. It is ideal as a safe interconnection point between the inverter or the microinverter string and the main distribution board, both in installations with grid export and in those requiring export limitation through external monitoring systems.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 7.4 kW (32 A at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e230 V~ · 50 Hz (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eModular polycarbonate enclosure · Class II (double insulation) · IK7\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMiniature circuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e2P 32 A · curve C · 6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 2 poles · immunized\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV · with fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated PV\/AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 231 × 238 × 118 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with single-phase inverters of ~5–7.5 kW and strings of microinverters (Enphase, Hoymiles, etc.) as long as the total does not exceed 32 A at 230 V. Integrable with monitoring systems via external current transformers and can be coordinated with upstream protections (main circuit breaker, main residual current device, and main SPD) according to the project.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACM32SDA 7.4kW 32A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, organization, and reliability in the AC branch of your installation, optimizing assembly times and the protection of equipment and people from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502778286421,"sku":"GAVEPRO003","price":148.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACM-SDA_1aa84e51-2028-4043-b0a3-0aa589d390ad.png?v=1762626051"},{"product_id":"caja-protecciones-ac-gave-acm40sda-9-2kw-40a-30ma","title":"AC Protection Box Single-phase GAVE ACM40SDA 9.2kW 40A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACM40SDA 9.2kW 40A 30mA Single-Phase AC Protection Box\u003c\/strong\u003e is a turnkey modular panel for protecting and connecting an AC branch of up to 9.2 kW in self-consumption or backup installations. It combines in a single Class II polycarbonate enclosure (double insulation) and IK7 the disconnection, miniature circuit breaker protection, high-sensitivity residual current protection, and transient surge protection (Type II SPD), speeding up assembly, organizing the installation, and facilitating compliance with best practices.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase 230 V · 50 Hz, 1 dedicated AC circuit with continuous capacity up to 40 A (≈ 9.2 kVA\/kW).\u003c\/li\u003e\n  \u003cli\u003e2P 40 A miniature circuit breaker (MCB), curve C, breaking capacity 6 kA (EN 60898-1).\u003c\/li\u003e\n  \u003cli\u003eType A residual current device (RCD) 30 mA, 2 poles, immune to unwanted tripping.\u003c\/li\u003e\n  \u003cli\u003eType II SPD surge protection (In 20 kA, Imax 40 kA, Up 1.5 kV) with associated fuse.\u003c\/li\u003e\n  \u003cli\u003eCompact polycarbonate enclosure with double insulation Class II and IK7 resistance rating.\u003c\/li\u003e\n  \u003cli\u003eInternal wiring and DIN rail arrangement for quick and maintainable installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and cleaner installation by centralizing protections, disconnection, and connection of the PV\/AC branch.\u003c\/li\u003e\n  \u003cli\u003eIncreased safety: 30 mA RCD for personal protection and Type II SPD to mitigate grid transients.\u003c\/li\u003e\n  \u003cli\u003eFacilitates technical compliance and selectivity with upstream protections.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: front access to devices, clear labeling, and streamlined wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eIdeal as an interconnection and safety point between single-phase inverters of ~6–9 kW or strings of microinverters (aggregate ≤ 40 A) and the main distribution board in residential or small commercial settings. Also valid in AC-coupled battery schemes when the line current does not exceed 40 A.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 9.2 kW (40 A at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e230 V~ · 50 Hz (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate enclosure · Class II (double insulation) · IK7\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMiniature circuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e2P 40 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 2 poles · immunized (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV · with fuse (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated PV\/AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 231 × 238 × 118 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with single-phase inverters of ~6–9 kW and with microinverter strings (Enphase, Hoymiles, etc.) as long as the total does not exceed 40 A at 230 V. Can be coordinated with main circuit breaker, main residual current device, and main SPD according to the project, and can be integrated with monitoring via external current transformers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACM40SDA 9.2kW 40A 30mA Single-phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, organization, and reliability in the AC branch of your installation, optimizing assembly times and protecting equipment and people.\u003c\/p\u003e\n","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502778319189,"sku":"GAVEPRO004","price":149.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACM-SDA_0ef16bc0-1a57-4c5f-9c2b-53215c28af08.png?v=1762626053"},{"product_id":"caja-protecciones-ac-gave-act10sda-7kw-10a-30ma","title":"Three-phase AC Protection Box GAVE ACT10SDA 7kW 10A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACT10SDA 7kW 10A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e brings together in a single 3F+N enclosure everything needed to connect and protect a three-phase AC branch of up to ~7 kW. It incorporates a four-pole circuit breaker, high-sensitivity Type A residual current device, and Type II surge protection device (SPD), providing electrical safety, organized wiring, and fast, professional installation in residential or small tertiary applications.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase panel 3F+N for 1 circuit with capacity up to 10 A per phase (≈ 6.9–7 kVA at 3×400 V).\u003c\/li\u003e\n  \u003cli\u003e4P 10 A circuit breaker, curve C, breaking capacity 6 kA in accordance with EN 60898-1.\u003c\/li\u003e\n  \u003cli\u003eType A residual current device 30 mA (immune to unwanted tripping) according to EN 61008-1.\u003c\/li\u003e\n  \u003cli\u003eOvervoltage protection SPD Type II (In 20 kA, Imax 40 kA, Up 1.5 kV) according to EN 61643-11.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure, double insulation Class II, high mechanical resistance, suitable for protected outdoor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and cleaner installation: centralizes disconnection, protections, and interconnection point.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety for people and equipment with 30 mA RCD and Type II SPD in the same panel.\u003c\/li\u003e\n  \u003cli\u003eFacilitated technical compliance and streamlined wiring for easy maintenance.\u003c\/li\u003e\n  \u003cli\u003eCompact format with DIN rail and accessible terminals that optimize the available space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eIdeal as a protection panel for residential or small tertiary three-phase self-consumption, branches of three-phase microinverters or low-power string inverters (~5–7 kW), and AC-coupled battery systems when the line current does not exceed 10 A per phase.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 7 kW (10 A\/phase at 3×400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate · Class II (double insulation) · DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMagnetothermal protection\u003c\/td\u003e\n\u003ctd\u003e4P 10 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4 poles (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated three-phase AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with three-phase microinverters (e.g., HMT\/MIT branches or other ecosystems) and with three-phase string inverters of ~5–7 kW, provided the aggregate does not exceed 10 A per phase. Integrable with monitoring systems via external CT\/meters and can be coordinated with main circuit breaker, general residual current device, and main SPD according to the project.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACT10SDA 7kW 10A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, order, and reliability in the AC interface of your installation, optimizing assembly times and protecting equipment and people from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502778351957,"sku":"GAVEPRO005","price":249.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-SDA.png?v=1762626057"},{"product_id":"caja-protecciones-ac-gave-act16sda-11kw-16a-30ma","title":"Three-phase AC Protection Box GAVE ACT16SDA 11kW 16A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACT16SDA 11kW 16A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e brings together in a single 3F+N enclosure all critical safety functions for an AC branch of up to ~11 kW: isolation, circuit breaker protection, high-sensitivity residual current protection, and overvoltage limitation (Type II SPD). Its modular design with double insulation (Class II) in polycarbonate enables quick, tidy installation in accordance with best practices, reducing installation time and future interventions.\u003c\/p\u003e\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase 3F+N configuration for 1 AC circuit with capacity up to 16 A\/phase (≈ 11 kVA\/kW at 3×400 V).\u003c\/li\u003e\n  \u003cli\u003eMiniature circuit breaker (MCB) 4P 16 A, curve C, breaking capacity 6 kA (EN 60898-1).\u003c\/li\u003e\n  \u003cli\u003eResidual current device (RCD) Type A 30 mA, 4 poles, immune to unwanted tripping (EN 61008-1).\u003c\/li\u003e\n  \u003cli\u003eOvervoltage protection SPD Type II (In 20 kA, Imax 40 kA, Up 1.5 kV) in accordance with EN 61643-11.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure with double insulation Class II, high mechanical strength, and DIN rail.\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions (≈ 286 × 418 × 148 mm) that facilitate integration into the technical room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAgile installation: turnkey panel that centralizes protections, isolation, and interconnection point.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety: 30 mA RCD protects people and Type II SPD mitigates grid transients.\u003c\/li\u003e\n  \u003cli\u003eClean and maintainable installation: streamlined wiring, accessible terminals, and clear labeling.\u003c\/li\u003e\n  \u003cli\u003eFacilitates technical compliance and selectivity with upstream protections from the main distribution board.\u003c\/li\u003e\n  \u003cli\u003eVersatility: suitable for 3-phase string inverters ~8–12 kW or branches of three-phase microinverters (≤ 16 A\/phase).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for residential and small tertiary three-phase self-consumption, as well as for AC-coupled battery schemes when the line current does not exceed 16 A\/phase. Functions as a safe and professional interconnection point between the AC generator\/backup and the main distribution board, with or without export limitation depending on the monitoring system configuration.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 11 kW (16 A\/phase at 3×400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (3F+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eModular polycarbonate enclosure · Class II (double insulation) · DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMagnetothermal protection\u003c\/td\u003e\n\u003ctd\u003e4P 16 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4 poles · immunized (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated three-phase AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with three-phase inverters of ~8–12 kW and with 3F microinverter branches (Enphase HMT\/MIT or others), provided the total does not exceed \u003cstrong\u003e16 A\/phase\u003c\/strong\u003e. Can be coordinated with main circuit breaker, general residual current device, and main SPD according to the project, and can be integrated with monitoring via current transformers or external meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGAVE ACT16SDA 11kW 16A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, order, and reliability in the AC interface of your installation, optimizing assembly times and protecting equipment and people from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502779760981,"sku":"GAVEPRO006","price":245.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-SDA_4bddfa48-08f1-40cb-b24d-0f8ddd70902e.png?v=1762626061"},{"product_id":"caja-protecciones-ac-gave-act25sda-17kw-25a-30ma","title":"Three-Phase AC Protection Box GAVE ACT25SDA 17kW 25A 30mA","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACT25SDA 17kW 25A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is a turnkey 3P+N panel that combines isolation, circuit breaker protection, residual current protection, and surge protection in a single Class II enclosure. Designed for three-phase installations up to ~17 kW, it simplifies wiring, speeds up commissioning, and ensures a safe and organized AC interface between the generator\/backup and the main panel.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCapacity: up to 25 A per phase (≈ 17.3 kVA\/kW at 3×400\/230 V, 50 Hz).\u003c\/li\u003e\n  \u003cli\u003e4P 25 A circuit breaker (MCB), curve C, breaking capacity 6 kA (EN 60898-1).\u003c\/li\u003e\n  \u003cli\u003e4P Type A 30 mA residual current device (RCD) with design immune to unwanted tripping (EN 61008-1).\u003c\/li\u003e\n  \u003cli\u003eType II surge protection device (SPD) (In 20 kA · Imax 40 kA · Up 1.5 kV) according to EN 61643-11.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure with double insulation Class II, high mechanical strength, and DIN rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eQuick and clean installation: centralizes protections, isolation, and interconnection point.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety for people and equipment with integrated 30 mA RCD and Type II SPD.\u003c\/li\u003e\n  \u003cli\u003eFacilitated technical compliance and streamlined wiring for agile maintenance.\u003c\/li\u003e\n  \u003cli\u003eCompact and robust format that optimizes space in technical rooms or protected outdoor cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for residential\/tertiary three-phase self-consumption and light C\u0026I with inverters of ~12–18 kW or 3P microinverter branches (always ≤ 25 A\/phase). Also suitable for systems with AC-coupled batteries when the line current does not exceed the nominal limit.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 17.3 kW (25 A\/phase at 3×400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate · Class II (double insulation) · DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e4P 25 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4 poles · immune (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated three-phase AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with three-phase string inverters of ~12–18 kW and 3P microinverter branches, provided the aggregate does not exceed \u003cstrong\u003e25 A\/phase\u003c\/strong\u003e. Can be coordinated with main circuit breaker, main RCD, and main SPD as per project; can be integrated with monitoring via CT or external meters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACT25SDA 17kW 25A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, order, and reliability in the AC interface of your installation, optimizing assembly times and protecting equipment and people from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502779793749,"sku":"GAVEPRO007","price":246.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-SDA_bfeb8dfe-f220-4dab-882e-e61d28049904.png?v=1762626064"},{"product_id":"caja-protecciones-ac-gave-act32sda-22kw-32a-30ma","title":"Three-Phase AC Protection Box GAVE ACT32SDA 22kW 32A 30mA","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is a turnkey 3F+N panel that centralizes protections, disconnection, and the interconnection point of the AC branch in installations up to ~22 kW. It integrates a four-pole miniature circuit breaker, high-sensitivity residual current device, and surge protection device (SPD Type II) in a polycarbonate enclosure with double insulation (Class II), offering quick, organized installation in accordance with best practices.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase 3F+N capacity for 1 AC circuit: up to 32 A\/phase (≈ 22.1 kVA\/kW at 3×400\/230 V).\u003c\/li\u003e\n  \u003cli\u003eMiniature circuit breaker (MCB) 4P 32 A, curve C, breaking capacity 6 kA (EN 60898-1).\u003c\/li\u003e\n  \u003cli\u003eResidual current device (RCD) 4P Type A 30 mA, immune to unwanted tripping (EN 61008-1).\u003c\/li\u003e\n  \u003cli\u003eSurge protection SPD Type II – PSTC440: In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11).\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure Class II (double insulation), high mechanical strength, DIN rail, and streamlined wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFast and clean installation by concentrating all AC-side protections in a single panel.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety for people (RCD 30 mA) and equipment (Type II SPD against transients).\u003c\/li\u003e\n  \u003cli\u003eFacilitates technical compliance and selectivity with upstream protections.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: front access to devices, accessible terminals, and clear labeling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for residential\/tertiary three-phase self-consumption and light C\u0026I with string inverters of ~15–22 kW or 3F microinverter branches, as well as for systems with AC-coupled batteries when the line current does not exceed 32 A per phase.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 22.1 kW (32 A\/phase at 3×400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (3F+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate · Class II (double insulation) · DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMiniature circuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e4P 32 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4 poles · immune (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated three-phase AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with three-phase inverters of ~15–22 kW and with 3F microinverter branches (provided the total does not exceed \u003cstrong\u003e32 A\/phase\u003c\/strong\u003e). Can be coordinated with main circuit breaker, general RCD, and main SPD as per project; can be integrated with monitoring via CT or external meters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is the professional option to centralize safety, organization, and reliability at the AC interface of your installation, optimizing installation time and protecting equipment and people from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502779892053,"sku":"GAVEPRO008","price":245.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-SDA_a24a1e19-88f5-499f-ad01-89eb0445d7ee.png?v=1762626066"},{"product_id":"caja-protecciones-ac-gave-act40sda-28kw-40a-30ma","title":"Three-phase AC Protection Box GAVE ACT40SDA 28kW 40A 30mA","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACT40SDA 28kW 40A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e centralizes all critical AC-side functions in a single 3F+N enclosure: isolation, circuit breaker protection, residual current protection, and surge protection. Designed for installations up to ~28 kW at 3×400\/230 V, it combines calibrated switchgear and a compact polycarbonate format with double insulation (Class II, IK7), offering quick, organized assembly in compliance with current standards for three-phase inverters and microinverters.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase 3F+N capacity for 1 AC circuit with up to 40 A per phase (≈ 27.7–28 kVA\/kW at 3×400 V).\u003c\/li\u003e\n  \u003cli\u003e4P 40 A circuit breaker (MCB), curve C, breaking capacity 6 kA (EN 60898-1) against overloads and short circuits.\u003c\/li\u003e\n  \u003cli\u003e4P Type A 30 mA residual current device (RCD), immune to unwanted tripping, personal protection (EN 61008-1).\u003c\/li\u003e\n  \u003cli\u003eType II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) according to EN 61643-11, with associated fuse.\u003c\/li\u003e\n  \u003cli\u003eClass II polycarbonate enclosure, high mechanical resistance (IK7), DIN rail, and streamlined internal wiring.\u003c\/li\u003e\n  \u003cli\u003eApproximate dimensions: 286 × 418 × 148 mm (height × width × depth).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and cleaner installation by concentrating all AC-side protections in a single panel.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety for people (RCD 30 mA) and equipment (Type II SPD that mitigates grid transients).\u003c\/li\u003e\n  \u003cli\u003eFacilitates technical compliance: selectivity with upstream protections and SPD coordination.\u003c\/li\u003e\n  \u003cli\u003eEasy maintenance thanks to front access, accessible terminals, and clear labeling.\u003c\/li\u003e\n  \u003cli\u003eRobust format suitable for protected indoor or outdoor use, ideal for demanding residential and light C\u0026I environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned as an interconnection and safety point between the AC generator\/backup and the main panel in three-phase installations. It is ideal for string inverters of ~18–28 kW or branches of 3-phase microinverters, as well as for systems with AC-coupled batteries when the line current does not exceed 40 A per phase. Suitable for residential, small commercial, and light C\u0026I applications requiring a reliable, monitorable, and scalable AC interface.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 28 kW (40 A\/phase at 3×400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (three-phase 3F+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate enclosure · Class II (double insulation) · IK7 · DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMagnetothermal protection\u003c\/td\u003e\n\u003ctd\u003e4P 40 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResidual current protection\u003c\/td\u003e\n\u003ctd\u003eType A · 30 mA · 4 poles · immunized (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV · with fuse (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated three-phase AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with three-phase inverters of ~18–28 kW and with 3F microinverter strings, provided the aggregate does not exceed \u003cstrong\u003e40 A\/phase\u003c\/strong\u003e. Integrable with monitoring systems via CT or external meters and can be coordinated with main circuit breaker, general residual current device, and main SPD according to the project.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACT40SDA 28kW 40A 30mA Three-Phase AC Protection Box\u003c\/strong\u003e is a professional solution for demanding self-consumption and light C\u0026I projects. Increases safety, streamlines installation, and ensures a reliable and orderly AC interconnection from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502779924821,"sku":"GAVEPRO009","price":257.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-SDA_2851f66c-79d3-4136-90e2-e0b4dbb4ceb6.png?v=1762626069"},{"product_id":"caja-protecciones-ac-gave-act63sda-44kw-63a-300ma","title":"Three-phase AC Protection Box GAVE ACT63SDA\/300 44kW 63A 300mA","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE ACT63SDA\/300 44kW 63A 300mA Three-Phase AC Protection Box\u003c\/strong\u003e is a turnkey 3F+N panel designed to protect and connect, with maximum reliability, high-flow AC branches in three-phase installations. It integrates, in a single polycarbonate enclosure with double insulation (Class II) and IK08, a four-pole 63 A circuit breaker, a Type A \u003cem\u003eselective\u003c\/em\u003e 300 mA residual current device—ideal for fire protection and to ensure selectivity with downstream RCDs—and a Type II surge protection device (SPD). With this configuration, the panel reduces installation time, organizes wiring, and ensures technical compliance in self-consumption, backup, or light\/medium C\u0026I systems up to ~44 kW.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical capacity: up to 63 A per phase (≈ 43.6–44 kVA\/kW at 3×400\/230 V, 50 Hz).\u003c\/li\u003e\n  \u003cli\u003e4P 63 A circuit breaker (MCB), curve C, 6 kA breaking capacity according to EN 60898-1.\u003c\/li\u003e\n  \u003cli\u003e4P Type A 300 mA \u003cem\u003eselective\u003c\/em\u003e RCD, immune to unwanted tripping (EN 61008-1).\u003c\/li\u003e\n  \u003cli\u003eType II SPD (In 20 kA, Imax 40 kA, Up 1.5 kV) with associated fuse (EN 61643-11).\u003c\/li\u003e\n  \u003cli\u003eClass II polycarbonate enclosure, high impact resistance IK08, suitable for protected outdoor use.\u003c\/li\u003e\n  \u003cli\u003eStreamlined internal wiring and DIN rail for quick, clean, and maintainable installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelectivity and service continuity:\u003c\/strong\u003e the 300 mA (S) RCD reduces nuisance tripping, protects against fire risk, and maintains selectivity with 30 mA RCDs in subpanels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated safety:\u003c\/strong\u003e circuit breaker, RCD, and SPD in the same panel protect people and equipment against overloads, indirect contact, and network transients.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgile and orderly installation:\u003c\/strong\u003e fewer field connections, accessible terminals, and clear labeling shorten commissioning and facilitate maintenance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTechnical compliance:\u003c\/strong\u003e switchgear and construction in accordance with IEC\/EN standards, facilitating audits and legal certification of installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobustness and durability:\u003c\/strong\u003e quality materials, double insulation Class II, and IK08 for demanding environments (indoor or protected outdoor).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned to act as an interconnection and safety point between AC generation\/backup and the main panel in high-power three-phase installations. Its use is ideal in advanced residential self-consumption, tertiary, and light\/medium C\u0026I, with string inverters of 30–40+ kW or branches of three-phase microinverters, as well as in systems with AC-coupled batteries when the line current does not exceed 63 A\/phase. It is also suitable for schemes with export limitation and energy monitoring via CT or external meters.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e≈ 44 kW (63 A\/phase at 3×400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e3×400\/230 V~ · 50 Hz (three-phase 3F+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate enclosure · Class II (double insulation) · IK08\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuit breaker protection\u003c\/td\u003e\n\u003ctd\u003e4P 63 A · curve C · 6 kA (EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRCD protection\u003c\/td\u003e\n\u003ctd\u003eType A · 300 mA · 4 poles · selective S (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up 1.5 kV · with fuse (EN 61643-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003e1 dedicated three-phase AC circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with three-phase inverters of 30–40+ kW and with 3F microinverter branches, provided the aggregate does not exceed \u003cstrong\u003e63 A\/phase\u003c\/strong\u003e. It can be integrated with monitoring systems (CT\/meters), selectivity with IGA and 30 mA RCDs in subpanels, and coordination with main SPD according to project and local regulations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE ACT63SDA\/300 44kW 63A 300mA Three-Phase AC Protection Box\u003c\/strong\u003e is a professional solution for demanding projects: it provides comprehensive safety, differential selectivity, panel organization, and reliability at the AC interface, optimizing installation times and protecting equipment and people from day one.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502779957589,"sku":"GAVEPRO010","price":340.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/ENPHASE-ACT-SDA_81e75e98-ed06-4e2f-abef-c275bd96b131.png?v=1762626071"},{"product_id":"caja-protecciones-dc-gave-stm11025p15-2-2mppt-15a-1000v","title":"DC PV Protection Box GAVE STM11025P15\/2 2 MPPT 1 String 15A 1000V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC PV Protection Box GAVE STM11025P15\/2 2 MPPT 1 String 15A 1000V\u003c\/strong\u003e is a complete and compact solution for direct current protection in photovoltaic installations with \u003cem\u003etwo MPPT\u003c\/em\u003e inverters and \u003cem\u003eone string per MPPT\u003c\/em\u003e. It integrates, in a single Class II enclosure with IP65 and IK08 protection rating, 15 A gPV fuses for each pole, a general isolator of 25 A–1000 VDC per output, and dedicated PV Type II surge protection devices per MPPT. The result is a ready-to-use outdoor panel, quick to install and focused on reliability, which simplifies the interconnection between the strings and the inverter and ensures selectivity and safe maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2E\/2S architecture: 2 independent MPPTs with 1 string per MPPT (differentiated input and output +\/–).\u003c\/li\u003e\n  \u003cli\u003egPV fuses 10×38 mm of 15 A per pole and per string for protection against reverse currents.\u003c\/li\u003e\n  \u003cli\u003eGeneral DC isolator 25 A – 1000 VDC for safe operation during maintenance tasks.\u003c\/li\u003e\n  \u003cli\u003ePV Type II surge protection per MPPT (PST31PV cartridges): In 20 kA, Imax 40 kA, Up ≈ 3.6 kV, Uc ≈ 1060 VDC.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure, \u003cstrong\u003eIP65\u003c\/strong\u003e, \u003cstrong\u003eIK08\u003c\/strong\u003e, double insulation \u003cstrong\u003eClass II\u003c\/strong\u003e, suitable for outdoor use.\u003c\/li\u003e\n  \u003cli\u003eCompatible with inverters up to \u003cstrong\u003e1000 VDC\u003c\/strong\u003e and string current ≤ 15 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety and compliance:\u003c\/strong\u003e gPV fuses, load isolation, and PV Type II SPD in accordance with applicable standards, protecting modules, cabling, and inverter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNeat installation:\u003c\/strong\u003e clear distribution per MPPT (MPPT1\/MPPT2), accessible terminals, and labeling that reduces field errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgile maintenance:\u003c\/strong\u003e quick isolation at 1000 VDC and easy replacement of gPV cartridges and surge protectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor reliability:\u003c\/strong\u003e IP65 and IK08 for operation on rooftops or outdoors with watertightness and impact resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSustained performance:\u003c\/strong\u003e SPD coordination and selective protection that minimize downtime due to transients or failures from reverse current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eThis box is designed for residential and small commercial installations with \u003cem\u003etwo MPPT\u003c\/em\u003e inverters and a single string per MPPT. It is ideal when a robust DC panel is required that provides gPV fuse, isolator, and PV SPD in a single unit, keeping wiring organized and allowing future inspection tasks without risks. Suitable for pitched or flat roofs, pergolas, and ground-mounted systems where the \u003cem\u003eVoc\u003c\/em\u003e of the strings does not exceed 1000 VDC and the \u003cem\u003eIsc\u003c\/em\u003e of each string is ≤ 15 A.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eAccording to generator; branch nominal current 25 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 VDC per MPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eIP65 enclosure · IK08 · Class II (polycarbonate)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInputs\/Outputs\u003c\/td\u003e\n\u003ctd\u003e2 inputs (+\/–) → 2 independent outputs (+\/–) per MPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFuses\u003c\/td\u003e\n\u003ctd\u003egPV 10×38 mm · 15 A per pole and per string\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIsolator\u003c\/td\u003e\n\u003ctd\u003e25 A – 1000 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD PV\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up ≈ 3.6 kV · Uc ≈ 1060 VDC (per MPPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with string inverters with 2 MPPT and input up to 1000 VDC (Huawei, Growatt, Fronius, SMA, GoodWe, Solis, Deye, etc.), provided that \u003cem\u003eVoc\u003c\/em\u003e at the minimum project temperature ≤ 1000 VDC and the \u003cem\u003eIsc\u003c\/em\u003e of the string ≤ 15 A. Suitable for 54\/60\/72\/78 cell modules, sizing the number of panels in series so as not to exceed the voltage limit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDC PV Protection Box GAVE STM11025P15\/2 2 MPPT 1 String 15A 1000V\u003c\/strong\u003e is a professional solution for demanding PV projects: it increases DC side safety, simplifies wiring, and improves installation availability thanks to its combination of gPV fuses, 1000 VDC isolator, and PV Type II surge protectors per MPPT.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502779990357,"sku":"GAVEPRO014","price":338.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/GAVE-STM11025P15-2.png?v=1762626074"},{"product_id":"caja-protecciones-dc-gave-stm11025p20-2-2mppt-20a-1000v","title":"DC PV Protection Box GAVE STM11025P20\/2 2 MPPT 1 String 20A 1000V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC PV Protection Box GAVE STM11025P20\/2 2 MPPT 1 String 20A 1000V\u003c\/strong\u003e is a direct current panel designed for inverters with two trackers (MPPT) and one string for each. It combines in a single IP65 IK08 and Class II enclosure the 20 A gPV fuses, the main 40 A 1000 VDC isolator, and Type II PV surge protection devices per MPPT. With this 2E\/2S architecture (two independent inputs and two independent outputs), a safer, more organized, and easier-to-maintain installation is achieved, perfect for residential rooftops and small commercial applications.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTopology 2 MPPT × 1 string\/MPPT (2 inputs \/ 2 outputs differentiated by MPPT).\u003c\/li\u003e\n  \u003cli\u003egPV fuses 10×38 mm of 20 A per pole and per string to prevent reverse currents.\u003c\/li\u003e\n  \u003cli\u003eMultipole DC isolator 40 A – 1000 VDC for safe operation and maintenance.\u003c\/li\u003e\n  \u003cli\u003eType II PV surge protection per MPPT (PST31PV cartridges): In 20 kA, Imax 40 kA, Up ≈ 3.6 kV, Uc ≈ 1060 VDC.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure \u003cstrong\u003eIP65\u003c\/strong\u003e, \u003cstrong\u003eIK08\u003c\/strong\u003e, and double insulation \u003cstrong\u003eClass II\u003c\/strong\u003e, suitable for outdoor use.\u003c\/li\u003e\n  \u003cli\u003eTerminals and internal distribution designed for PV cable of 4–6–10 mm² and simple grounding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eQuick and clean installation: clear MPPT1\/MPPT2 wiring, marked polarities, and easy access to fuses and SPD.\u003c\/li\u003e\n  \u003cli\u003eMaximum DC side safety: load isolation, selective gPV protection, and coordinated PV SPD.\u003c\/li\u003e\n  \u003cli\u003eImproved availability and service life: transients are mitigated and the risk of damage to modules and inverter is minimized.\u003c\/li\u003e\n  \u003cli\u003eAgile maintenance: simple replacement of gPV cartridges and surge protectors; visual inspection of SPD status.\u003c\/li\u003e\n  \u003cli\u003eOutdoor robustness: IP65 and IK08 ensure watertightness and impact resistance on rooftops or outdoors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIndicated for residential self-consumption and light commercial installations with inverters of \u003cem\u003e2 MPPT\u003c\/em\u003e and one string for each, where the \u003cem\u003eVoc\u003c\/em\u003e of the strings does not exceed 1000 VDC and the \u003cem\u003eIsc\u003c\/em\u003e is ≤ 20 A. It is ideal in systems with high-current modules (e.g., N-type or bifacial) and when isolation, gPV fuses, and PV SPD are required in a single box, keeping the panel organized and ready for audits and maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePV DC · 2 MPPT · 1 string per MPPT (2E\/2S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. system voltage\u003c\/td\u003e\n\u003ctd\u003e1000 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated box current\u003c\/td\u003e\n\u003ctd\u003e25 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMain isolator\u003c\/td\u003e\n\u003ctd\u003e40 A – 1000 VDC (multi-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFuses per MPPT\u003c\/td\u003e\n\u003ctd\u003egPV 20 A · 10×38 mm · one fuse per pole and string\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD per MPPT\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up ≈ 3.6 kV · Uc ≈ 1060 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInputs \/ Outputs\u003c\/td\u003e\n\u003ctd\u003e2 (+\/–) → 2 (+\/–) independent per MPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate · IP65 · IK08 · Class II (double insulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 286 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with string inverters of 2 MPPT and input up to 1000 VDC (Huawei, Growatt, Fronius, SMA, GoodWe, Solis, Deye, etc.), \u003cem\u003eprovided\u003c\/em\u003e that \u003cstrong\u003eVoc_total\u003c\/strong\u003e at the minimum project temperature is ≤ 1000 VDC and the \u003cstrong\u003eIsc\u003c\/strong\u003e of each string is ≤ 20 A. Suitable for modules of 54\/60\/66\/72\/78 cells, sizing the number in series to respect voltage and current limits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDC PV Protection Box GAVE STM11025P20\/2 2 MPPT 1 String 20A 1000V\u003c\/strong\u003e is a professional solution for demanding PV projects: it increases DC side safety, simplifies wiring, and improves installation availability thanks to the combination of 20 A gPV fuses, 40 A\/1000 VDC isolator, and Type II PV SPD per MPPT.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502780023125,"sku":"GAVEPRO015","price":338.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/GAVE-STM11025P20-2.png?v=1762626075"},{"product_id":"caja-protecciones-dc-gave-stm11040p12-1mppt-12a-1000v","title":"DC PV Protection Box GAVE STM11040P12 1 MPPT 1 String 12A 1000V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC PV Protection Box GAVE STM11040P12 1 MPPT 1 String 12A 1000V\u003c\/strong\u003e concentrates, in a compact and robust format, all critical safety functions for the direct current side of a photovoltaic installation with \u003cem\u003eone MPPT and a single string\u003c\/em\u003e. It incorporates a 12 A gPV fuse per pole to protect against reverse currents, a general 40 A 1000 VDC isolator that allows safe operation and maintenance, and a Type II PV surge arrester that protects the inverter and generator against transients. Its polycarbonate enclosure with double insulation (Class II), IP65 and IK7 protection rating, is designed for outdoor use (depending on installation) and to withstand the demands of rooftops and residential or small commercial environments. The internal DIN rail layout, accessible terminals, and clear labeling reduce installation time and facilitate future inspections.\u003c\/p\u003e\n\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1E\/1S topology: 1 MPPT with 1 string (differentiated input and output in +\/–).\u003c\/li\u003e\n  \u003cli\u003egPV fuses 10×38 mm of 12 A per pole for selectivity and protection against reverse currents.\u003c\/li\u003e\n  \u003cli\u003eMultipole DC isolator 40 A – 1000 VDC to isolate the circuit during maintenance operations.\u003c\/li\u003e\n  \u003cli\u003eType II PV surge protection (PST31PV cartridge): In 20 kA, Imax 40 kA, Up ≈ 3.6 kV, Uc ≈ 1060 VDC.\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure IP65 · IK7 · Class II (double insulation), suitable for protected outdoor use.\u003c\/li\u003e\n  \u003cli\u003eCompact design (≈ 231 × 238 × 118 mm) with streamlined wiring and integrated earth terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eQuick and tidy installation: marked polarities, front access to fuses and isolator, reduced risk of error.\u003c\/li\u003e\n  \u003cli\u003eGreater DC side safety: load disconnection, selective gPV protection, and PV SPD coordinated with the inverter.\u003c\/li\u003e\n  \u003cli\u003eReduced downtime: transients are mitigated and the inverter is protected against overvoltages.\u003c\/li\u003e\n  \u003cli\u003eSimple maintenance: quick replacement of gPV cartridges and visual verification of SPD status.\u003c\/li\u003e\n  \u003cli\u003eOutdoor robustness: IP65 and IK7 ensure watertightness and mechanical resistance on rooftops and pergolas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIndicated for residential self-consumption and light commercial use when using an inverter with \u003cstrong\u003e1 MPPT\u003c\/strong\u003e and a single string. It is ideal as an interconnection point between the photovoltaic generator and the DC input of the inverter in rooftop or ground installations, provided that the string \u003cem\u003eVoc\u003c\/em\u003e at the minimum design temperature does not exceed 1000 VDC and the \u003cem\u003eIsc\u003c\/em\u003e is compatible with the 12 A gPV fuse. It provides the functions required by best practices: gPV fuse per pole, DC isolator, and PV-type surge protection.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eAccording to generator; branch admissible current up to 40 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 VDC (Uoc_total of the string ≤ 1000 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eIP65 · IK7 · Class II (polycarbonate) enclosure with DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInputs \/ Outputs\u003c\/td\u003e\n\u003ctd\u003e1 input (+\/–) → 1 output (+\/–)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFuses\u003c\/td\u003e\n\u003ctd\u003egPV 12 A · 10×38 mm · one fuse per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIsolator\u003c\/td\u003e\n\u003ctd\u003e40 A – 1000 VDC (multi-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD PV\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up ≈ 3.6 kV · Uc ≈ 1060 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 231 × 238 × 118 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with inverters with 1 MPPT up to 1000 VDC input and with strings whose \u003cem\u003eVoc\u003c\/em\u003e at minimum temperature ≤ 1000 VDC and \u003cem\u003eIsc\u003c\/em\u003e ≤ 12 A. Suitable for modules with 54\/60\/66\/72\/78 cells, sizing the number in series to respect voltage and current limits. Integrates earth connection via dedicated terminal and coordinates with the inverter or main SPD, when present, following applicable IEC\/EN standards.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDC PV Protection Box GAVE STM11040P12 1 MPPT 1 String 12A 1000V\u003c\/strong\u003e is a professional solution to protect and isolate the DC side with maximum order, safety, and reliability, optimizing assembly time and the availability of your photovoltaic installation.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502780055893,"sku":"GAVEPRO013","price":223.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/GAVE-STM11040P12.png?v=1762626078"},{"product_id":"caja-protecciones-dc-gave-stm21025p15s-3-3mppt-15a-1000v","title":"DC PV Protection Box GAVE STM21025P15S\/3 3 MPPT 2 Strings 15A 1000V","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGAVE STM21025P15S\/3 DC PV Protection Box 3 MPPT 2 Strings 15A 1000V\u003c\/strong\u003e is a direct current photovoltaic panel designed for inverters with three MPPT trackers and \u003cem\u003etwo strings per MPPT\u003c\/em\u003e. It combines in a single Class II outdoor-rated enclosure the gPV fuse protection for each string, MPPT-level isolation at 1000 VDC, and Type II PV surge protection per MPPT, offering a clean, safe, and very easy-to-maintain installation.\u003c\/p\u003e\n\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3×MPPT architecture with 2 strings per MPPT (6E\/6S) with independent outputs to each inverter input.\u003c\/li\u003e\n  \u003cli\u003egPV 10×38 fuses of 15 A per pole and per string to prevent reverse currents and protect the generator.\u003c\/li\u003e\n  \u003cli\u003eDedicated isolation per MPPT: DC switches 25 A – 1000 V for safe operation and maintenance.\u003c\/li\u003e\n  \u003cli\u003eType II PV surge protection per MPPT (PST31PV cartridges): In 20 kA, Imax 40 kA, Up ≈ 3.6 kV, Uc ≈ 1060 VDC.\u003c\/li\u003e\n  \u003cli\u003eClass II polycarbonate enclosure, IK7 mechanical resistance, and protection rating suitable for outdoor use.\u003c\/li\u003e\n  \u003cli\u003eApproximate dimensions: 436 × 418 × 148 mm (height × width × depth).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAdvantages or benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and tidier installation: clear distribution by MPPT, polarity labeling, and accessible terminals.\u003c\/li\u003e\n  \u003cli\u003eComprehensive DC side safety: load isolation, selective fuse protection, and coordinated PV SPD.\u003c\/li\u003e\n  \u003cli\u003eEnhanced availability: transients are diverted to ground and the risk of damage to modules and inverter is minimized.\u003c\/li\u003e\n  \u003cli\u003eAgile maintenance: easy replacement of gPV cartridges and visual verification of the status of the surge arresters.\u003c\/li\u003e\n  \u003cli\u003eScalability: prepared for advanced residential and light C\u0026I with three trackers and two strings per tracker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePurpose or applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-power residential installations and small C\u0026I with inverters featuring 3 MPPTs operating with 2 strings per MPPT. Ideal for rooftops or ground installations where MPPT-level isolation, string-level fusing, and dedicated PV SPD are required, keeping the DC panel organized and in accordance with best practices.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePV DC · 3 MPPT · 2 strings per MPPT (6 inputs \/ 6 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. system voltage\u003c\/td\u003e\n\u003ctd\u003e1000 VDC (Voc_total at minimum T ≤ 1000 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnection\u003c\/td\u003e\n\u003ctd\u003e3 DC disconnectors 25 A – 1000 V (one per MPPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eString protection\u003c\/td\u003e\n\u003ctd\u003egPV fuses 15 A · 10×38 mm on + and − of each string\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD per MPPT\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up ≈ 3.6 kV · Uc ≈ 1060 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInputs \/ Outputs\u003c\/td\u003e\n\u003ctd\u003e6E (+\/−) → 6S (+\/−) grouped by MPPT (2+2+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate · Class II (double insulation) · IK7 · suitable for outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e436 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 3 MPPT inverters up to 1000 VDC input (common manufacturers) that support 2 strings\/MPPT, provided that the \u003cstrong\u003eIsc\u003c\/strong\u003e of each string ≤ 15 A and the \u003cstrong\u003eVoc_total\u003c\/strong\u003e at the project's minimum temperature ≤ 1000 VDC. Suitable for 54\/60\/66\/72\/78 cell modules by sizing the series number to respect limits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGAVE STM21025P15S\/3 DC PV Protection Box 3 MPPT 2 Strings 15A 1000V\u003c\/strong\u003e is a professional solution for demanding PV projects: it centralizes DC side protection, enhances safety, and reduces assembly and maintenance times.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502780285269,"sku":"GAVEPRO016","price":623.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/GAVE-STM21025P15S-3.png?v=1762626080"},{"product_id":"caja-protecciones-dc-gave-stm21025p15s-4-4mppt-15a-1000v","title":"DC PV Protection Box GAVE STM21025P15S\/4 4 MPPT 2 Strings 15A 1000V","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC PV Protection Box GAVE STM21025P15S\/4 4 MPPT 2 Strings 15A 1000V\u003c\/strong\u003e is a professional DC panel that centralizes, in a single IP65 IK7 and Class II enclosure, all critical functions to protect and isolate photovoltaic generators with \u003cem\u003efour MPPT trackers\u003c\/em\u003e and \u003cem\u003etwo strings per MPPT\u003c\/em\u003e (8E\/8S). It incorporates 15 A gPV fuses per pole and per string, independent DC disconnectors of 25 A–1000 V for each MPPT, and Type II PV surge protection devices also per MPPT. This architecture simplifies wiring, speeds up commissioning, and ensures fast and safe maintenance in advanced residential, light commercial, and C\u0026I installations.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNative topology: 4 MPPT × 2 strings per MPPT (8 inputs \/ 8 outputs with differentiated polarities).\u003c\/li\u003e\n  \u003cli\u003eString protection: 15 A 10×38 mm gPV fuses installed on the + and − poles of each string (16 fuses in total).\u003c\/li\u003e\n  \u003cli\u003eDedicated disconnection per tracker: 4 DC disconnectors of 25 A at 1000 V allowing safe operation and maintenance per MPPT.\u003c\/li\u003e\n  \u003cli\u003eSurge protection: Type II PV SPD per MPPT (In 20 kA · Imax 40 kA · Up ≈ 3.6 kV · Uc ≈ 1060 VDC).\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate enclosure, double insulation Class II, \u003cstrong\u003eIP65\u003c\/strong\u003e and \u003cstrong\u003eIK7\u003c\/strong\u003e, suitable for outdoor use depending on installation.\u003c\/li\u003e\n  \u003cli\u003eInternal DIN rail distribution with accessible terminals, clear labeling, and space for PV cable 4–6–10 mm².\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFaster and cleaner installation: grouping by MPPT, identification of strings and polarities, and reduced risk of connection errors.\u003c\/li\u003e\n  \u003cli\u003eComprehensive DC side safety: load disconnection, selectivity by gPV fuse, and transient discharge via Type II SPD.\u003c\/li\u003e\n  \u003cli\u003eAgile maintenance: MPPT isolation in seconds, easy replacement of gPV cartridges, and visual verification of SPD status.\u003c\/li\u003e\n  \u003cli\u003eTechnical compliance: components and construction aligned with best practices and IEC\/EN PV protection standards.\u003c\/li\u003e\n  \u003cli\u003eOutdoor robustness: IP65 and IK7 sealing that protects the equipment against dust, water, and impacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for string inverters with \u003cstrong\u003e4 MPPT\u003c\/strong\u003e and input up to 1000 VDC working with two strings per tracker. It is ideal for high-power residential rooftops, small ground-mounted plants, and light C\u0026I where MPPT disconnection, string fusing, and dedicated surge protection are required, keeping the DC panel organized and ready for audits, preventive maintenance, and future expansions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePV DC · 4 MPPT · 2 strings per MPPT (8E\/8S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. system voltage\u003c\/td\u003e\n\u003ctd\u003e1000 VDC (Voc_total at minimum T ≤ 1000 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisconnection\u003c\/td\u003e\n\u003ctd\u003e4× DC disconnector 25 A – 1000 V (one per MPPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFuses per string\u003c\/td\u003e\n\u003ctd\u003egPV 15 A · 10×38 mm on + and − (16 fuses in total)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSPD per MPPT\u003c\/td\u003e\n\u003ctd\u003eType II · In 20 kA · Imax 40 kA · Up ≈ 3.6 kV · Uc ≈ 1060 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent per MPPT\u003c\/td\u003e\n\u003ctd\u003eUp to 25 A DC (limited by its disconnector)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate · Class II (double insulation) · IP65 · IK7\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e≈ 586 × 418 × 148 mm (height × width × depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with four-tracker inverters (Huawei, Fronius, SMA, GoodWe, Solis, Deye, etc.) that support 2 strings\/MPPT and input up to 1000 VDC, provided that the \u003cstrong\u003eIsc\u003c\/strong\u003e of each string is ≤ 15 A and the \u003cstrong\u003eVoc_total\u003c\/strong\u003e at the minimum project temperature does not exceed 1000 VDC. Requires equipotential bonding of the structure, low-impedance grounding, and coordination with the inverter\/upstream SPD.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDC PV Protection Box GAVE STM21025P15S\/4 4 MPPT 2 Strings 15A 1000V\u003c\/strong\u003e is a professional solution for demanding PV projects: it centralizes protections, improves operational safety, and reduces installation and maintenance times on the DC interface of your system.\u003c\/p\u003e","brand":"GAVE","offers":[{"title":"Default Title","offer_id":51502780383573,"sku":"GAVEPRO017","price":770.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/GAVE-STM21025P15S-4.png?v=1762626082"}],"url":"https:\/\/aurensol.net\/en\/collections\/gave.oembed","provider":"Aurensol","version":"1.0","type":"link"}