{"title":"Cables and Hoses","description":"\u003ch2\u003eWhat are Cables and Hoses for solar?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eCables and Hoses\u003c\/strong\u003e collection includes conductors specifically for photovoltaics and auxiliary electrical wiring, with halogen-free compounds, UV\/ozone resistance, and jackets designed for outdoor and indoor use.\u003c\/p\u003e\n\n\u003ch3\u003eAdvantages and limitations\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety\u003c\/strong\u003e enhanced by low smoke emission and toxicity.\u003c\/li\u003e\n  \u003cli\u003eDurability against solar radiation and extreme temperatures.\u003c\/li\u003e\n  \u003cli\u003eLimitation: each cross-section and type has admissible currents; size correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePV strings (DC), connections to inverter, and monitoring connections.\u003c\/li\u003e\n  \u003cli\u003eInterconnections in panels and AC lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to choose\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCalculate cross-section based on \u003cstrong\u003ecurrent\u003c\/strong\u003e, \u003cstrong\u003evoltage drop\u003c\/strong\u003e, and service temperature.\u003c\/li\u003e\n  \u003cli\u003eSelect insulation and jacket (e.g., EN 50618\/IEC 62930 for PV).\u003c\/li\u003e\n  \u003cli\u003eEnsure compatibility with \u003ca href=\"\/en\/collections\/conectores-terminales\"\u003econnectors\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/protecciones-electricas-cc\"\u003efuses\/disconnectors\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications (indicative)\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTypical PV standard\u003c\/td\u003e\n\u003ctd\u003eEN 50618 \/ IEC 62930\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-40…+90 °C (depending on model)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-sections\u003c\/td\u003e\n\u003ctd\u003e2.5–35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eJacket\u003c\/td\u003e\n\u003ctd\u003eHalogen-free, UV, flame retardant\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV AC – 1.5 kV DC (depending on cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eComparisons and related\u003c\/h3\u003e\n\u003cp\u003eComplete with \u003ca href=\"\/en\/collections\/conectores-terminales\"\u003eConnectors and Terminals\u003c\/a\u003e, \u003ca href=\"\/en\/collections\/cuadros-cajas-electricas\"\u003ePanels and Boxes\u003c\/a\u003e, and protections in \u003ca href=\"\/en\/collections\/protecciones-electricas-cc\"\u003eDC\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/protecciones-electricas-ca\"\u003eAC\u003c\/a\u003e. Overview in \u003ca href=\"\/en\/collections\/material-electrico\"\u003eElectrical Material\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"cable-rz1-k-1x10-mm-libre-halogeno","title":"RZ1-K Green Cable 1x10mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Cable 1x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible single-core low voltage cable designed for safe installations in buildings, industry, and solar energy. Its construction with class 5 copper conductor and XLPE (cross-linked polyethylene) insulation ensures excellent electrical and thermal performance, while the halogen-free polyolefin sheath minimizes the emission of smoke and corrosive gases in case of fire. It complies with \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, making it suitable for public spaces and indoor, outdoor, or even buried installations.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e for low voltage AC networks.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eClass 5 copper\u003c\/strong\u003e conductor (high flexibility) for faster installation and tight bends.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation and \u003cstrong\u003ehalogen-free\u003c\/strong\u003e polyolefin sheath, low smoke emission.\u003c\/li\u003e\n\u003cli\u003eCertified fire performance: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eindoor, outdoor, in conduit, tray, or buried\u003c\/strong\u003e installations.\u003c\/li\u003e\n\u003cli\u003eConductor service temperature: \u003cstrong\u003e90 °C\u003c\/strong\u003e; test voltage: \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety\u003c\/strong\u003e in buildings and civil works: very low smoke opacity and zero halogen emission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e and dimensional stability thanks to XLPE insulation (better thermal resistance).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e: suitable for photovoltaic (DC\/AC balance of plant), industrial, and general uses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy installation\u003c\/strong\u003e: flexible class 5 conductor simplifies routing through conduits and trays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy identification\u003c\/strong\u003e by green color and standardized marking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDistribution and transmission of low voltage energy (0.6\/1 kV) in homes, public buildings, industrial facilities, and solar plants (AC connection of inverters, panels, service lines, and lighting). Suitable for outdoor installation, in ducts, or directly buried according to applicable regulations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/Polyolefin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (Type DIX3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free polyolefin (LSZH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. outer diameter\u003c\/td\u003e\n\u003ctd\u003e8.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.91 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C on conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPR classification\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with standard 10 mm² cable glands, ferrules, and terminals, as well as common electrical conduits (tube, tray, trench). Use protections and cross-sections according to REBT and voltage drop calculations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Cable 1x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e offers a safe and durable solution for low voltage wiring in residential, commercial, industrial, and photovoltaic projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503325839701,"sku":"REVICAB001","price":2.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-UNIPOLAR-RZ1.png?v=1762629966"},{"product_id":"cable-rz1-k-1x16-mm-libre-halogeno","title":"RZ1-K Green Cable 1x16mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Cable 1x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is designed for high-demand low voltage lines where safety, durability, and reduced voltage drop are prioritized. Its class 5 copper conductor provides flexibility for easy installation, while the \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation improves thermal performance compared to traditional PVC. The polyolefin \u003cstrong\u003eLSZH\u003c\/strong\u003e (halogen-free) sheath minimizes the emission of smoke and corrosive gases, meeting the stringent \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e standard. It is suitable for indoor, outdoor, tray-mounted, conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e installations, making it a versatile cable for building, civil works, and photovoltaic plant balance of system.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e and test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFlexible class 5 copper\u003c\/strong\u003e conductor for quick and safe installation.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation and LSZH sheath with \u003cstrong\u003elow smoke emission\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, suitable for public spaces.\u003c\/li\u003e\n\u003cli\u003eContinuous conductor service at \u003cstrong\u003e90 °C\u003c\/strong\u003e, excellent thermal margin.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor\/outdoor\/buried\u003c\/strong\u003e use in accordance with UNE 21123-4 standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarger cross-section (16 mm²)\u003c\/strong\u003e to reduce voltage drop in main feeds and risers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong service life\u003c\/strong\u003e under demanding conditions due to the thermal and mechanical stability of XLPE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive safety\u003c\/strong\u003e in case of fire: less smoke, halogen-free, and low corrosivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign flexibility\u003c\/strong\u003e: suitable for tray, conduit, wells, and trenches; valid as main supply line, branches, and panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy identification\u003c\/strong\u003e by green color and standardized marking for efficient maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eMain feeds in buildings and warehouses, branches to main and plant panels, service entries, and low voltage internal networks. In photovoltaics, suitable as AC cabling for inverters, distribution panels, and connections to the transformer station when a larger cross-section is required due to current or length.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/Polyolefin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (Type DIX3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePolyolefin LSZH, halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. outer diameter\u003c\/td\u003e\n\u003ctd\u003e9.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.21 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C on conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPR classification\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts 16 mm² terminals\/lugs, cable glands, and standardized conduits. Use protections and installation methods according to REBT, ITC-BT, and calculations for admissible current and voltage drop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Cable 1x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is the professional choice for low voltage lines with high safety, reliability, and performance requirements in residential, commercial, industrial, and photovoltaic environments.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503325938005,"sku":"REVICAB002","price":3.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-UNIPOLAR-RZ1_3b1fc68a-83b5-4192-bd55-178ee650f4bc.png?v=1762629967"},{"product_id":"cable-rz1-k-1x25-mm-libre-halogeno","title":"RZ1-K Cable Green 1x25mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Cable 1x25mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible single-core low voltage cable designed for main power supply in buildings, industry, and photovoltaic plant balance of system. Class 5 copper conductor for easy installation even in tight bending radii, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation that withstands service temperatures up to 90 °C, and a \u003cstrong\u003eLSZH\u003c\/strong\u003e (halogen-free) sheath with very low emission of smoke and corrosive gases. Its fire reaction classification \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e allows its use in public spaces, shopping centers, parking lots, or critical infrastructure, providing safety and service continuity. Suitable for installation \u003cstrong\u003eindoors\u003c\/strong\u003e, \u003cstrong\u003eoutdoors\u003c\/strong\u003e, on tray, in conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e, offering versatility for new construction and renovations.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e (AC) · Test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eConductor: \u003cstrong\u003eclass 5 electrolytic copper\u003c\/strong\u003e (high flexibility) 1×25 mm².\u003c\/li\u003e\n  \u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e (cross-linked polyethylene) with excellent thermal stability.\u003c\/li\u003e\n  \u003cli\u003eSheath: \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free, low smoke opacity and toxicity.\u003c\/li\u003e\n  \u003cli\u003eInstallation: indoor\/outdoor, on tray, in conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e in trench.\u003c\/li\u003e\n  \u003cli\u003eCompliance: \u003cstrong\u003eUNE 21123-4\u003c\/strong\u003e and \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced safety\u003c\/strong\u003e in case of fire: very low smoke emission and zero halogen release.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower voltage drop\u003c\/strong\u003e compared to smaller cross-sections; ideal for long runs or high currents.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLong service life\u003c\/strong\u003e due to its XLPE insulation and sheath resistant to chemicals and moisture.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy installation\u003c\/strong\u003e thanks to class 5 conductor and good handling properties.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile\u003c\/strong\u003e: suitable for service entries, riser columns, panels, and low voltage internal networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003ePower supply for main and plant panels, individual branch circuits, service lines in public buildings, warehouses, and parking lots, as well as AC cabling in solar plants and rooftops (from inverters to panels\/CT), where CPR compliance and smoke reduction are a priority.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 0.780 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer diameter\u003c\/td\u003e\n\u003ctd\u003e11–12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (short-circuit 250 °C max., 5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction\u003c\/td\u003e\n\u003ctd\u003eCPR Cca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, conduit, tray, buried\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts 25 mm² ferrules\/terminals, metric cable glands, and standard fittings. Size protections and cross-section according to REBT\/ITC-BT, permissible current, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Cable 1x25mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e provides CPR safety, thermal robustness, and electrical efficiency for demanding low voltage power supplies.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326101845,"sku":"REVICAB003","price":5.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-UNIPOLAR-RZ1_51277cef-bf58-4562-b2f0-44b6d2e203c0.png?v=1762629971"},{"product_id":"cable-rz1-k-1x35-mm-libre-halogeno","title":"RZ1-K Green Cable 1x35mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Cable 1x35mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is designed for low voltage lines with high currents and long runs, such as riser columns, main connections, and feeds between panels. Its RZ1-K (AS) construction combines a \u003cstrong\u003eclass 5 copper conductor\u003c\/strong\u003e—which facilitates routing in trays and conduits—with \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C in service) and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath. The \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e fire reaction reduces smoke opacity and toxicity, aiding evacuation and asset protection in buildings and public spaces. Suitable for indoor and outdoor installation, exposed or in conduit, as well as \u003cstrong\u003eburied\u003c\/strong\u003e in trench according to regulations.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService at \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e · Tested at \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCu class 5\u003c\/strong\u003e conductor 1×35 mm²: high current capacity and manageability.\u003c\/li\u003e\n  \u003cli\u003eHigh thermal and dielectric resistance \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eLSZH\u003c\/strong\u003e sheath: low smoke emission, halogen-free.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e certification for safety-critical applications.\u003c\/li\u003e\n  \u003cli\u003eVersatile installation: indoor, outdoor, tray, conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimal voltage drop\u003c\/strong\u003e due to its large cross-section; ideal for long feeds or concentrated loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh service continuity\u003c\/strong\u003e in demanding industrial and commercial environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced safety\u003c\/strong\u003e: very low smoke, halogen-free, and low acidity in case of fire.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation savings\u003c\/strong\u003e by allowing reduced bending radii compared to rigid conductors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e against moisture, chemicals, and temperature thanks to its XLPE insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRiser columns, LGA, branch circuits to floor panels, connections from transformer substations to main panels, inverter feeders, and AC distribution in solar plants or warehouses, where CPR compatibility and maximum operational reliability are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 0.554 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer diameter\u003c\/td\u003e\n\u003ctd\u003e12.5–13.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (short-circuit 250 °C, 5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction\u003c\/td\u003e\n\u003ctd\u003eCPR Cca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, conduit, tray, buried\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eUse with 35 mm² terminals\/lugs, cable glands, and standardized accessories. Select protections and supports according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Cable 1x35mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is the technical choice for connections and main lines that require maximum CPR safety and superior electrical performance.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326200149,"sku":"REVICAB004","price":7.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-UNIPOLAR-RZ1_9c090b8f-beed-4dc5-8cad-5c5290fb40da.png?v=1762629972"},{"product_id":"cable-rz1-k-1x50-mm-libre-halogeno","title":"RZ1-K Green Cable 1x50mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Cable 1x50mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible single-core cable with a large cross-section for main low voltage lines with high currents and long runs. It combines class 5 copper conductor for agile installation, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation with continuous service at 90 °C, and a halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath that reduces smoke and corrosive gases. Complies with \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, making it suitable for public buildings, industry, and photovoltaic plant balance of system (AC).\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e · Test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConductor: \u003cstrong\u003eclass 5 copper\u003c\/strong\u003e 1×50 mm², high current capacity.\u003c\/li\u003e\n\u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e (cross-linked polyethylene) 90 °C service \/ 250 °C short-circuit 5 s.\u003c\/li\u003e\n\u003cli\u003eSheath: \u003cstrong\u003eLSZH\u003c\/strong\u003e (halogen-free), low smoke emission and opacity.\u003c\/li\u003e\n\u003cli\u003eInstallation: indoor, outdoor, in tray, conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eStandard: \u003cstrong\u003eUNE 21123-4\u003c\/strong\u003e · Fire reaction \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimal voltage drop\u003c\/strong\u003e in high-demand service lines and risers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPR safety\u003c\/strong\u003e in environments with evacuation and service continuity requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong service life\u003c\/strong\u003e due to the thermal and mechanical stability of XLPE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick installation\u003c\/strong\u003e thanks to the flexible class 5 conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile\u003c\/strong\u003e: suitable for civil works, industry, and solar plants (AC side).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRisers, main distribution board feeds, transformer substation branches, internal LV networks, and AC distribution in photovoltaic plants where large cross-section and CPR compliance are required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×50 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 0.386 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C service \/ 250 °C 5 s sc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eLSZH polyolefin, halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. outer diameter\u003c\/td\u003e\n\u003ctd\u003e14–16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPR classification\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eSuitable for 50 mm² terminals and ferrules, metric cable glands, and standardized conduits. Size protections and voltage drop according to REBT and ITC-BT.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Cable 1x50mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e guarantees CPR safety and superior electrical performance in critical low voltage feeds.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326298453,"sku":"REVICAB005","price":8.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-UNIPOLAR-RZ1_39200458-4ae6-4238-aeb6-1042eeba3cbd.png?v=1762629975"},{"product_id":"cable-rz1-k-1x6-mm-libre-halogeno","title":"RZ1-K Green Cable 1x6mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Cable 1x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible single-core cable for low voltage distribution that prioritizes safety and ease of installation. It incorporates a class 5 copper conductor, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation rated for 90 °C service, and a halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath with very low emission of smoke and corrosive gases. Its \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e certification makes it suitable for public buildings, residential properties, offices, industry, and photovoltaic plant balance of system (AC side).\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e · Test \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eClass 5 copper\u003c\/strong\u003e conductor 1×6 mm²: high flexibility for routing in conduit\/tray.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation and \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath with low smoke emission.\u003c\/li\u003e\n\u003cli\u003eFire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInstallation \u003cstrong\u003eindoors, outdoors, or buried\u003c\/strong\u003e according to UNE 21123-4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced safety\u003c\/strong\u003e in case of fire (halogen-free, low smoke).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior handling\u003c\/strong\u003e due to its flexible class 5 conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e: service lines, lighting, small feeders, and AC uses in PV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e and thermal stability thanks to XLPE (90 °C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy identification\u003c\/strong\u003e by green color and standardized marking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDistribution circuits and individual branch lines in buildings, industry, and solar plants (AC from inverters and panels). Suitable for tray, corrugated conduit, or trench, complying with REBT and ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.30 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C service \/ 250 °C 5 s short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e polyolefin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. outer diameter\u003c\/td\u003e\n\u003ctd\u003e7.0–7.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPR classification\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts 6 mm² terminals\/lugs, metric cable glands, and standard conduits. Select protections and cross-section according to REBT and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Cable 1x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is the safe and versatile option for low voltage wiring with CPR requirements.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326396757,"sku":"REVICAB006","price":1.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-UNIPOLAR-RZ1_f5ee211a-101e-4f1c-bab7-57008210ccbd.png?v=1762629977"},{"product_id":"cable-solar-negro-1x10-mm-100-metros","title":"Solar Cable H1Z2Z2-K Black 1x10mm² 100m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable H1Z2Z2-K Black 1x10mm² 100m 1500V DC\u003c\/strong\u003e is a professional photovoltaic cable for self-consumption installations and industrial projects. Manufactured according to EN 50618 with tinned electrolytic copper class 5 and cross-linked HFFR insulation\/sheath, it offers high flexibility, fire safety, and great resistance to weather, UV, and ozone. It is perfect for connecting solar panels, long strings, and DC connections to the inverter or protection boxes.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage: 1.5 kV DC (max. permissible 1.8 kV DC) and 1\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eConductor: tinned copper class 5 (flexible) according to UNE-EN\/IEC 60228.\u003c\/li\u003e\n  \u003cli\u003eInsulation and sheath: cross-linked HFFR, halogen-free, UV stabilized (EN 50363-5 EI5).\u003c\/li\u003e\n  \u003cli\u003eThermal range: ambient −40…+90 °C; conductor up to +120 °C.\u003c\/li\u003e\n  \u003cli\u003eFire resistance: flame retardant (IEC\/EN 60332-1-2).\u003c\/li\u003e\n  \u003cli\u003eExternal protection: UV resistant (EN 50618, TÜV 2Pfg 1169-08) and ozone resistant (EN 50396).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLonger outdoor lifespan thanks to its UV-stabilized HFFR sheath.\u003c\/li\u003e\n  \u003cli\u003eLower losses due to its 10 mm² cross-section and anti-corrosion tinned copper.\u003c\/li\u003e\n  \u003cli\u003eQuick installation: high flexibility and reduced bending radius (15×Ø).\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety: halogen-free and low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eUniversal compatibility with standard DC connectors and protections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eConnection of photovoltaic modules in series\/parallel, string downleads to DC combiner boxes, connections to the inverter, and runs in tray or conduit on residential, commercial, or industrial rooftops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K · EN 50618\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 1\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eTinned copper class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eCross-linked HFFR, halogen-free, EI5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e7.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15 × Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.95 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 200 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eEN 50618 · EN 50396\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e100 m coil\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e134 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlame\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4\/derivative connectors, DC string boxes, photovoltaic protections, and 1500 V DC PV inverter inputs. For negative or positive polarity according to installer coding. Connectors not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable H1Z2Z2-K Black 1x10mm² 100m 1500V DC\u003c\/strong\u003e is the safe and durable option for string wiring in high-performance photovoltaic installations.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326495061,"sku":"REVICAB007","price":196.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-NEGRO-1.png?v=1762629981"},{"product_id":"cable-solar-negro-1x16-mm-por-metros","title":"Solar Cable H1Z2Z2-K Black 1x16mm² per Meter 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable H1Z2Z2-K Black 1x16mm² per Meter 1500V DC\u003c\/strong\u003e is designed for photovoltaic applications where lower voltage drop and maximum robustness are required. It complies with EN 50618, uses a flexible tinned copper conductor and double cross-linked HFFR layer, halogen-free, with excellent resistance to UV radiation, ozone, and atmospheric agents. Supplied cut to length by the meter to precisely match your installation requirements.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage 1.5 kV DC (max. permissible 1.8 kV DC) and 1\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eFlexible class 5 conductor of 16 mm² with anti-corrosion tinning.\u003c\/li\u003e\n  \u003cli\u003eHFFR EI5 insulation\/sheath, halogen-free, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C ambient; up to +120 °C in the conductor.\u003c\/li\u003e\n  \u003cli\u003eDielectric test 6.5 kV AC \/ 15 kV DC; flame retardant.\u003c\/li\u003e\n  \u003cli\u003eUV resistant (EN 50618, TÜV 2Pfg 1169-08) and ozone resistant (EN 50396).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 mm² cross-section to minimize losses in long runs or high currents.\u003c\/li\u003e\n  \u003cli\u003eSupplied by the meter: zero waste, optimized costs.\u003c\/li\u003e\n  \u003cli\u003eExcellent mechanical and thermal performance outdoors and on roofs.\u003c\/li\u003e\n  \u003cli\u003eEasy installation due to its flexibility and 15×Ø bending radius.\u003c\/li\u003e\n  \u003cli\u003eElectrical and fire safety thanks to its HFFR compound.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for high-current string downleads, connection from combiner boxes to inverter, long-distance runs, and DC connections in residential, commercial, and industrial installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K · EN 50618\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 1\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eTinned copper class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eCross-linked HFFR, halogen-free, EI5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e8.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15 × Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.24 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 200 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eEN 50618 · EN 50396\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e195 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlame\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4\/derivative connectors, string boxes, and PV inverter inputs with 1500 V DC bus. Suitable for positive\/negative polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable H1Z2Z2-K Black 1x16mm² per Meter 1500V DC\u003c\/strong\u003e offers maximum reliability and minimal voltage drop in the DC wiring of your photovoltaic installation.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326593365,"sku":"REVICAB008","price":4.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-NEGRO-1_2dde5a2c-eb56-4f38-b448-f432bb6185b4.png?v=1762629984"},{"product_id":"cable-solar-negro-1x4-mm-100-metros","title":"Solar Cable H1Z2Z2-K Black 1x4mm² 100m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable H1Z2Z2-K Black 1x4mm² 100m 1500V DC\u003c\/strong\u003e is a professional photovoltaic cable compliant with EN 50618, designed for wiring modules, strings, and DC connections in self-consumption installations and industrial projects. It combines a class 5 tinned electrolytic copper conductor (high flexibility) with cross-linked halogen-free HFFR insulation and sheath, offering maximum resistance to aging from UV rays and ozone, excellent fire performance, and easy installation even in complex layouts.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage 1.5 kV DC (max. permissible 1.8 kV DC) and 1\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eFlexible class 5 tinned copper conductor, effective cross-section 4 mm².\u003c\/li\u003e\n  \u003cli\u003eHFFR compounds: low smoke emission, halogen-free, self-extinguishing.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C ambient and up to +120 °C in the conductor.\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to UV\/ozone and weathering for continuous outdoor use.\u003c\/li\u003e\n  \u003cli\u003eReduced bending radius (≥ 15×Ø) for easier installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCertified safety and durability: HFFR materials, flame retardant.\u003c\/li\u003e\n  \u003cli\u003eLow losses in typical residential\/commercial power strings.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor: greater protection against corrosion and humidity.\u003c\/li\u003e\n  \u003cli\u003eQuick installation due to its flexibility and compact outer diameter.\u003c\/li\u003e\n  \u003cli\u003e100 m coil: ideal format for construction sites and warehouse stock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eConnection of modules in series\/parallel, string downleads to combiner boxes, runs to the inverter, and installations on roofs, trays, or conduits in residential, commercial, or industrial systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K · EN 50618\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 1\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eCross-linked halogen-free HFFR (EI5)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e5.5–5.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 4.9 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 200 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eEN 50618 · EN 50396\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e100 m coil\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e≈ 65–70 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4 and equivalent connectors, DC string boxes, and PV inverter inputs up to 1500 V DC. Suitable for positive\/negative polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable H1Z2Z2-K Black 1x4mm² 100m 1500V DC\u003c\/strong\u003e ensures reliable, safe, and durable photovoltaic wiring with an excellent balance between flexibility and performance.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326724437,"sku":"REVICAB009","price":87.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-NEGRO-1_69d773e5-8a1e-4a7a-9e84-02001c9fd6d4.png?v=1762629986"},{"product_id":"cable-solar-rojo-1x10-mm-100-metros","title":"Solar Cable H1Z2Z2-K Red 1x10mm² 100m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable H1Z2Z2-K Red 1x10mm² 100m 1500V DC\u003c\/strong\u003e is a professional photovoltaic cable, ideal for marking the positive polarity in modern 1500 V systems. It complies with the EN 50618 standard and is manufactured with class 5 tinned electrolytic copper conductor, offering great flexibility and corrosion resistance. Its cross-linked HFFR insulation and sheath, halogen-free, provide maximum fire safety, low smoke emission, and excellent performance outdoors, under UV rays, and ozone. The 100 m reel format streamlines continuous string and DC run installation, reducing splices.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage 1.5 kV DC (max. permissible 1.8 kV DC) and 1\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eFlexible class 5 tinned copper conductor, 1×10 mm² cross-section.\u003c\/li\u003e\n  \u003cli\u003eHFFR EI5 insulation\/sheath, halogen-free, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eTemperature: ambient −40…+90 °C; conductor up to +120 °C.\u003c\/li\u003e\n  \u003cli\u003eUV\/ozone and weather resistance for continuous outdoor use.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius ≥ 15×Ø for safe installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRed color for clear identification of the positive polarity of the DC circuit.\u003c\/li\u003e\n  \u003cli\u003e10 mm² cross-section: lower losses in long runs and higher current strings.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor: greater durability in humid or saline environments.\u003c\/li\u003e\n  \u003cli\u003eHFFR compounds: enhanced safety in case of fire.\u003c\/li\u003e\n  \u003cli\u003eQuick installation thanks to its flexibility and compact outer diameter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eWiring of modules in series\/parallel, string downleads to combiner boxes, DC runs to the inverter, and installations in tray or conduit, both in residential and commercial or industrial systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K · EN 50618\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 1\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eCross-linked HFFR, halogen-free (EI5)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e≈ 7.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.95 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eEN 50618 · EN 50396\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e100 m reel\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire behavior\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4 and equivalent connectors, DC string boxes, and PV inverter inputs up to 1500 V DC. Use for positive polarity according to installer coding. Connectors not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable H1Z2Z2-K Red 1x10mm² 100m 1500V DC\u003c\/strong\u003e ensures safe, durable DC wiring with clear polarity identification in demanding photovoltaic installations.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326855509,"sku":"REVICAB013","price":196.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-ROJO-1_e8b76458-a0dc-4d8b-aee5-ead8d9b2b405.png?v=1762629989"},{"product_id":"cable-solar-rojo-1x16-mm-por-metros","title":"Solar Cable H1Z2Z2-K Red 1x16mm² per Meter 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable H1Z2Z2-K Red 1x16mm² per Meter 1500V DC\u003c\/strong\u003e is designed for sections with higher current or long distances where minimizing voltage drop is required. Certified according to EN 50618, it uses a class 5 tinned copper conductor that provides flexibility and corrosion protection, along with cross-linked HFFR insulation and sheath, halogen-free, with very low smoke emission and excellent resistance to UV radiation and ozone. Supplied by the meter, it allows for precise adjustment of the cable length, optimizing costs and avoiding unnecessary splices. Its red color facilitates identification of the positive polarity in the DC circuit.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eService voltage 1.5 kV DC (max. permissible 1.8 kV DC) and 1\/1 kV AC.\u003c\/li\u003e\n\u003cli\u003eFlexible class 5 conductor, 1×16 mm² cross-section, tinned copper.\u003c\/li\u003e\n\u003cli\u003eHFFR EI5 compounds, halogen-free, low smoke emission.\u003c\/li\u003e\n\u003cli\u003eThermal range: −40…+90 °C ambient; up to +120 °C in the conductor.\u003c\/li\u003e\n\u003cli\u003eHigh resistance to UV\/ozone and weathering for continuous outdoor use.\u003c\/li\u003e\n\u003cli\u003eRecommended bending radius ≥ 15×Ø for safe installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 mm² cross-section: minimal electrical losses in high-current feeders and strings.\u003c\/li\u003e\n\u003cli\u003eCut by the meter: zero waste and better material utilization.\u003c\/li\u003e\n\u003cli\u003eTinned conductor: longer service life in humid or saline environments.\u003c\/li\u003e\n\u003cli\u003eEnhanced safety: halogen-free and flame retardant.\u003c\/li\u003e\n\u003cli\u003eClear identification of positive polarity thanks to the red color.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for high-power string downleads, connection from combiner boxes to the inverter, long-distance runs, and DC feeders in residential, commercial, and industrial installations operating at 1000\/1500 V.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K · EN 50618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 1\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eCross-linked HFFR, halogen-free (EI5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e≈ 8.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.24 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eEN 50618 · EN 50396\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire behavior\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4\/derivative connectors, string boxes, and PV inverter inputs up to 1500 V DC. Recommended for positive polarity use. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable H1Z2Z2-K Red 1x16mm² per Meter 1500V DC\u003c\/strong\u003e offers maximum reliability, minimal voltage drop, and clear polarity identification in the DC wiring of demanding photovoltaic installations.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503326953813,"sku":"REVICAB014","price":4.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-ROJO-1_00088ae8-a04b-46d1-8f76-726a6341445d.png?v=1762629993"},{"product_id":"cable-solar-rojo-1x4-mm-100-metros","title":"Solar Cable H1Z2Z2-K Red 1x4mm² 100m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable H1Z2Z2-K Red 1x4mm² 100m 1500V DC\u003c\/strong\u003e is the professional option for clearly marking the positive polarity in photovoltaic string wiring. It complies with the EN 50618 standard and is manufactured with class 5 tinned electrolytic copper conductor (high flexibility and corrosion resistance), cross-linked halogen-free HFFR insulation and sheath, with low smoke emission and excellent performance against UV radiation and ozone. Its 100 m coil facilitates continuous and orderly runs on roofs, trays, and conduits, avoiding splices and reducing installation times. Thanks to its service voltage of 1.5 kV DC (1.8 kV DC max. permissible), it is suitable for modern residential, commercial, and industrial systems, offering safety, durability, and balanced electrical performance for 4 mm² sections.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage: 1.5 kV DC (max. permissible 1.8 kV DC) and 1\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eConductor: class 5 tinned copper, section 1×4 mm² (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eInsulation and sheath: cross-linked halogen-free HFFR (EI5), low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eWeather resistance: stabilized against UV and ozone for continuous outdoor use.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C in ambient; conductor up to +120 °C.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius: ≥ 15×Ø for safe and stress-free installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eImmediate identification of positive polarity thanks to the red color, minimizing connection errors.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor that improves protection against corrosion and humidity, ideal in coastal environments.\u003c\/li\u003e\n  \u003cli\u003eSafe fire behavior: halogen-free and non-flame propagating.\u003c\/li\u003e\n  \u003cli\u003e100 m coil format that speeds up installation and reduces splices.\u003c\/li\u003e\n  \u003cli\u003eExcellent balance between manageability, voltage drop, and cost in 4 mm².\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for connecting modules in series\/parallel, making string downleads to combiner boxes, and DC connections to inverters, both in residential self-consumption and in commercial roofs and industrial installations. Suitable for runs in trays, conduits, or directly on photovoltaic structures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K · EN 50618\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 1\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection\u003c\/td\u003e\n\u003ctd\u003e1×4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eCross-linked halogen-free HFFR (EI5)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e5.5–5.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 4.9 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh (suitable for continuous outdoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed (polarity +)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e100 m coil\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e≈ 65–70 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire behavior\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4 and equivalent connectors, DC string boxes, and PV inverter inputs up to 1500 V DC. Recommended for use as positive polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable H1Z2Z2-K Red 1x4mm² 100m 1500V DC\u003c\/strong\u003e provides polarity identification, safety, and long service life in the DC wiring of your photovoltaic installation.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327052117,"sku":"REVICAB015","price":87.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-ROJO-1.png?v=1762629997"},{"product_id":"cable-solar-negro-1x6-mm-100-metros","title":"Solar Cable PV1-F Black 1x6mm² 100m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable PV1-F Black 1x6mm² 100m 1500V DC\u003c\/strong\u003e is a cable specifically designed for photovoltaic applications in accordance with PV1-F\/TÜV, featuring a class 5 tinned copper conductor that ensures high flexibility and corrosion protection. Its insulation and sheath compounds are stabilized against ultraviolet radiation and ozone, so it maintains its electrical and mechanical properties outdoors for years. The 6 mm² cross-section balances voltage drop, manageability, and cost in residential and commercial installations.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage 1.5 kV DC (max. 1.8 kV DC) and 0.6\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eClass 5 tinned copper conductor (flexible), 6 mm².\u003c\/li\u003e\n  \u003cli\u003eHalogen-free compound insulation\/sheath, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eWide thermal range: −40…+90 °C ambient and up to +120 °C in conductor.\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to UV\/ozone, abrasion, and atmospheric agents.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius: ≥ 15×Ø for installation without stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLow electrical resistance to reduce losses in medium-length strings.\u003c\/li\u003e\n  \u003cli\u003eExcellent durability in sheath and structures without conduit.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor: better performance in humid or saline environments.\u003c\/li\u003e\n  \u003cli\u003e100 m coil format speeds up installation and avoids unnecessary splices.\u003c\/li\u003e\n  \u003cli\u003eUniversal compatibility with DC connectors and protection boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eConnection of modules, string parallels, downleads to combiner boxes, and DC runs to inverters in self-consumption, pumping, and commercial plant installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003ePV1-F · TÜV 2 Pfg 1169\/08.2007 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 0.6\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e6.1–6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.3 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 200 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh, suitable for continuous outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e100 m coil\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e≈ 90–100 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire behavior\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4\/derivative connectors, DC string boxes, and PV inputs of inverters up to 1500 V DC. Suitable for positive\/negative polarity. Connectors not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable PV1-F Black 1x6mm² 100m 1500V DC\u003c\/strong\u003e is the balanced solution for wiring strings and DC runs with reliability and long service life outdoors.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327183189,"sku":"REVICAB010","price":108.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-NEGRO-1_d5327553-68ad-42be-a27e-78f6053050e5.png?v=1762630001"},{"product_id":"cable-solar-negro-1x6-mm-25-metros","title":"Solar Cable PV1-F Black 1x6mm² 25m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable PV1-F Black 1x6mm² 25m 1500V DC\u003c\/strong\u003e is the professional solution for wiring photovoltaic strings and DC connections in residential and commercial installations. Manufactured according to the PV1-F standard (TÜV 2 PfG 1169\/08.2007 or equivalent), it features a class 5 tinned electrolytic copper conductor that provides great flexibility and corrosion resistance, along with halogen-free insulation and sheath, stabilized against UV radiation and ozone. Its 25 m format allows for precise short runs, avoiding unnecessary splices and reducing installation waste. With a service voltage of 1.5 kV DC, it is suitable for modern 1500 V systems and for 0.6\/1 kV in AC.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage: 1.5 kV DC (max. permissible 1.8 kV DC) and 0.6\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eConductor: class 5 tinned copper (flexible) of 1×6 mm².\u003c\/li\u003e\n  \u003cli\u003eInsulation and sheath: halogen-free HFFR compounds, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C ambient; up to +120 °C in the conductor.\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to UV rays, ozone, humidity, and abrasion for continuous outdoor use.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius ≥ 15×Ø for safe installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e25 m format: ideal for connections from module to nearby string box or inverter.\u003c\/li\u003e\n  \u003cli\u003eLower electrical losses in typical runs thanks to its 6 mm² cross-section.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor: prevents oxidation and improves reliability in saline or humid environments.\u003c\/li\u003e\n  \u003cli\u003eEnhanced safety: does not propagate flame and is halogen-free.\u003c\/li\u003e\n  \u003cli\u003eQuick installation due to its flexibility and compact outer diameter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eConnection of modules in series\/parallel, string downleads to DC combiner boxes, short runs to inverter, rooftop or tray installations, residential and commercial self-consumption projects, solar pumping, and small plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003ePV1-F · TÜV 2 PfG 1169\/08.2007 (or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 0.6\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e6.1–6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.3 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eHFFR compounds, halogen-free, low smoke emission\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV\/Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh, suitable for continuous outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e25 m roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4 and equivalent photovoltaic connectors, DC string boxes, and PV inputs of inverters with 1500 V DC bus. Suitable for positive or negative polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable PV1-F Black 1x6mm² 25m 1500V DC\u003c\/strong\u003e combines reliability, safety, and a practical format to optimize the DC wiring of your photovoltaic installation.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327281493,"sku":"REVICAB011","price":35.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-NEGRO-1_120fb7f0-f0e1-45cd-8560-f4b6962f753b.png?v=1762630004"},{"product_id":"cable-solar-negro-1x6-mm-50-metros","title":"Solar Cable PV1-F Black 1x6mm² 50m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable PV1-F Black 1x6mm² 50m 1500V DC\u003c\/strong\u003e is designed for DC wiring in photovoltaic installations that require medium continuous runs and high reliability. It complies with the PV1-F standard (TÜV 2 PfG 1169\/08.2007 or equivalent), uses class 5 tinned copper conductor for maximum flexibility and anti-corrosion protection, and a halogen-free insulation\/sheath combination with excellent resistance to UV rays, ozone, and atmospheric agents. With a service voltage of 1.5 kV DC, it is suitable for strings in 1000\/1500 V systems and supports 0.6\/1 kV in AC for auxiliary runs.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage: 1.5 kV DC (max. 1.8 kV DC) and 0.6\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eConductor: class 5 tinned copper, cross-section 1×6 mm².\u003c\/li\u003e\n  \u003cli\u003eHFFR compounds: halogen-free, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C ambient; up to +120 °C in conductor.\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to UV, ozone, humidity, and abrasion.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius ≥ 15×Ø.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e50 m format: lays medium runs without splices, reducing failure points.\u003c\/li\u003e\n  \u003cli\u003eBalance between voltage drop, manageability, and cost in 6 mm².\u003c\/li\u003e\n  \u003cli\u003eTinned conductor for demanding environments (coastal, industrial).\u003c\/li\u003e\n  \u003cli\u003eFire safety: flame retardant and low smoke toxicity.\u003c\/li\u003e\n  \u003cli\u003eLong service life outdoors thanks to its high UV\/ozone resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eConnection of photovoltaic modules, string parallels, downleads to combiner boxes, and DC connections to inverters in residential, commercial, solar pumping, and mini-plant systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003ePV1-F · TÜV 2 PfG 1169\/08.2007 (or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 0.6\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e6.1–6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.3 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eHalogen-free HFFR, low smoke emission\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV\/Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh, suitable for continuous outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e50 m roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eFully compatible with MC4 and equivalent connectors, DC string boxes, and PV inverter inputs with 1500 V DC bus. Suitable for positive\/negative polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable PV1-F Black 1x6mm² 50m 1500V DC\u003c\/strong\u003e provides a clean, safe, and durable layout for the DC wiring of your photovoltaic installation, optimizing assembly time and reliability.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327379797,"sku":"REVICAB012","price":59.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-NEGRO-1_c8dff522-02c1-47d9-a5bf-bf08e4914250.png?v=1762630005"},{"product_id":"cable-solar-rojo-1x6-mm-100-metros","title":"Solar Cable PV1-F Red 1x6mm² 100m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable PV1-F Red 1x6mm² 100m 1500V DC\u003c\/strong\u003e is a cable specifically designed for photovoltaic applications in compliance with PV1-F\/TÜV, designed to identify positive polarity and withstand demanding environmental conditions for years. It features a class 5 tinned electrolytic copper conductor (flexible and corrosion-resistant) with halogen-free compound insulation and sheath, low smoke emission, and high resistance to UV radiation and ozone. The 6 mm² cross-section offers an excellent balance between voltage drop, manageability, and cost, ideal for residential and commercial strings, downleads to combiner boxes, and DC connections to inverters in 1000\/1500 V systems.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage: 1.5 kV DC (max. permissible 1.8 kV DC) and 0.6\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eConductor: class 5 tinned copper, 1×6 mm², highly flexible.\u003c\/li\u003e\n  \u003cli\u003eHalogen-free compounds (HFFR), low smoke emission, and flame retardant.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C ambient; up to +120 °C in the conductor.\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to UV\/ozone and atmospheric agents for continuous outdoor use.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius: ≥ 15×Ø for effortless installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRed color facilitates identification of positive polarity in DC.\u003c\/li\u003e\n  \u003cli\u003eLower electrical losses in typical runs thanks to its 6 mm² cross-section.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor: superior protection against oxidation and humidity.\u003c\/li\u003e\n  \u003cli\u003eHigh safety: halogen-free and low smoke toxicity.\u003c\/li\u003e\n  \u003cli\u003e100 m coil for continuous runs, without unnecessary splices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for wiring modules in series\/parallel, string parallels, downleads to DC combiner boxes, and connections to inverters in residential self-consumption installations, commercial rooftops, solar pumping, and small plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003ePV1-F · TÜV 2 PfG 1169\/08.2007 (or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 0.6\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e6.1–6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.3 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eHFFR compounds, halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV\/Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh, suitable for continuous outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed (polarity +)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e100 m coil\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e≈ 90–100 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire behavior\u003c\/td\u003e\n\u003ctd\u003eNon-propagating (IEC\/EN 60332-1-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4 photovoltaic connectors and equivalents, DC string boxes, and PV inputs of inverters up to 1500 V DC. Recommended for use as positive polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable PV1-F Red 1x6mm² 100m 1500V DC\u003c\/strong\u003e combines safety, durability, and immediate polarity identification for reliable and professional DC wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327576405,"sku":"REVICAB016","price":108.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-ROJO-1_722026cf-ea85-4972-9be4-d8be7fc2d202.png?v=1762630008"},{"product_id":"cable-solar-rojo-1x6-mm-25-metros","title":"Solar Cable PV1-F Red 1x6mm² 25m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable PV1-F Red 1x6mm² 25m 1500V DC\u003c\/strong\u003e is the professional solution for identifying positive polarity in the wiring of strings and DC connections in modern photovoltaic installations. Manufactured in accordance with PV1-F (TÜV 2 PfG 1169\/08.2007 or equivalent), it uses a class 5 tinned electrolytic copper conductor that provides great flexibility and excellent corrosion resistance, along with halogen-free insulation and sheath compounds, low smoke emission, and high resistance to UV rays, ozone, and weathering. Its 6 mm² cross-section offers an optimal balance between voltage drop, manageability, and cost in typical residential and commercial self-consumption runs. In addition, the 25 m format helps to avoid unnecessary splices and reduce installation leftovers, streamlining assembly and improving the reliability of the wiring.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eService voltage: 1.5 kV DC (max. permissible 1.8 kV DC) and 0.6\/1 kV AC.\u003c\/li\u003e\n  \u003cli\u003eClass 5 tinned copper conductor (flexible), cross-section 1×6 mm².\u003c\/li\u003e\n  \u003cli\u003eHalogen-free HFFR insulation and sheath, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to UV radiation, ozone, humidity, and abrasion.\u003c\/li\u003e\n  \u003cli\u003eThermal range: −40…+90 °C in ambient; up to +120 °C in the conductor.\u003c\/li\u003e\n  \u003cli\u003eRecommended bending radius ≥ 15×Ø for safe installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRed color that facilitates immediate identification of positive polarity, reducing errors.\u003c\/li\u003e\n  \u003cli\u003eLower losses in typical runs thanks to the effective 6 mm² cross-section.\u003c\/li\u003e\n  \u003cli\u003eTinned conductor with greater protection against oxidation in humid or saline environments.\u003c\/li\u003e\n  \u003cli\u003eFire safety: halogen-free, flame retardant, and low smoke toxicity.\u003c\/li\u003e\n  \u003cli\u003e25 m format that optimizes costs in short runs and simplifies site logistics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDesigned for the connection of photovoltaic modules in series and parallel, string downleads to DC combiner boxes, and short connections to the inverter. Suitable for residential and commercial self-consumption installations, solar pumping, and small plants, whether in tray, conduit, or directly on photovoltaic structure, always complying with current installation regulations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003ePV1-F · TÜV 2 PfG 1169\/08.2007 (or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 0.6\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free HFFR compounds\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e6.1–6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.3 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh (suitable for continuous outdoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed (polarity +)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e25 m roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with MC4 and equivalent photovoltaic connectors, DC string boxes, and PV inputs of inverters with 1500 V DC bus. Recommended use for positive polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable PV1-F Red 1x6mm² 25m 1500V DC\u003c\/strong\u003e provides safe, durable, and perfectly identified DC wiring, optimizing time and costs in high-performance photovoltaic installations.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327707477,"sku":"REVICAB017","price":35.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-ROJO-1_d3e8ac0d-5d05-4954-ae6e-c7ddec365f11.png?v=1762630012"},{"product_id":"cable-solar-rojo-1x6-mm-50-metros","title":"Solar Cable PV1-F Red 1x6mm² 50m 1500V DC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolar Cable PV1-F Red 1x6mm² 50m 1500V DC\u003c\/strong\u003e is designed for direct current wiring in photovoltaic systems of 1000\/1500 V where clear identification of positive polarity is required and medium-length runs without splices are needed. Its tinned electrolytic copper class 5 conductor offers an optimal combination of flexibility, low resistance, and corrosion resistance, while the HFFR compound insulation and sheath, halogen-free, ensure fire safety and low smoke emission. In compliance with the PV1-F standard (TÜV 2 PfG 1169\/08.2007 or equivalent), this cable maintains electrical and mechanical performance even after years of exposure to UV radiation, ozone, and atmospheric agents, ensuring a long service life outdoors.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eService voltage 1.5 kV DC (max. permissible 1.8 kV DC) and 0.6\/1 kV AC.\u003c\/li\u003e\n\u003cli\u003eTinned copper conductor class 5 (flexible), 1×6 mm².\u003c\/li\u003e\n\u003cli\u003eHalogen-free insulation and sheath with low smoke emission (HFFR).\u003c\/li\u003e\n\u003cli\u003eVery high resistance to UV\/ozone, moisture, and abrasion for continuous outdoor use.\u003c\/li\u003e\n\u003cli\u003eThermal range: −40…+90 °C ambient; up to +120 °C in the conductor.\u003c\/li\u003e\n\u003cli\u003eRecommended bending radius ≥ 15×Ø for stress-free installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRed color to identify positive polarity and minimize connection errors.\u003c\/li\u003e\n\u003cli\u003e50 m format allows coverage of medium-length lines without splices, reducing failure points.\u003c\/li\u003e\n\u003cli\u003eTinned conductor with improved performance in humid or saline environments.\u003c\/li\u003e\n\u003cli\u003eEnhanced safety: halogen-free, flame retardant, and low smoke toxicity.\u003c\/li\u003e\n\u003cli\u003eIdeal balance between voltage drop, manageability, and cost in 6 mm² sections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for connecting modules in series\/parallel, paralleling strings, running down to combiner boxes, and connecting DC to inverters in residential, commercial, and solar pumping installations. Suitable for runs in tray, conduit, or on structure, always respecting bending radii and current installation standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType \/ Standard\u003c\/td\u003e\n\u003ctd\u003ePV1-F · TÜV 2 PfG 1169\/08.2007 (or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC (max. 1.8 kV DC) · 0.6\/1 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSection\u003c\/td\u003e\n\u003ctd\u003e1×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eTinned copper class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation \/ Sheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free HFFR compounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. outer Ø\u003c\/td\u003e\n\u003ctd\u003e6.1–6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending radius\u003c\/td\u003e\n\u003ctd\u003e≥ 15×Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003eAmbient −40…+90 °C · Conductor up to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.3 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric test\u003c\/td\u003e\n\u003ctd\u003e6.5 kV AC · 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV \/ Ozone resistance\u003c\/td\u003e\n\u003ctd\u003eHigh (suitable for continuous outdoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed (polarity +)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e50 m roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eFully compatible with MC4 and equivalent connectors, DC string boxes, and PV inverter inputs up to 1500 V DC. Recommended for use as positive polarity. Does not include connectors or terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Cable PV1-F Red 1x6mm² 50m 1500V DC\u003c\/strong\u003e provides safety, durability, and clear polarity identification in medium-length runs, optimizing the reliability of the DC wiring in your photovoltaic installation.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327871317,"sku":"REVICAB018","price":59.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/CABLE-SOLAR-6-MM-ROJO-1_73d962e3-b090-4c5d-b0ca-4cb6ce4b05e3.png?v=1762630015"},{"product_id":"manguera-rv-k-2x1-5-mm-100m","title":"RV-K Hose 2x1.5mm² 100m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 2x1.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e is a flexible power cable designed for demanding installations: solar energy, lighting, industrial, and domestic. It combines class 5 copper conductor with XLPE insulation and black PVC sheath, offering high mechanical robustness, weather resistance, and suitability for direct burial, conduit, or tray installation. Its design facilitates on-site work, shortens installation times, and guarantees long-term electrical safety.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 copper \u003cstrong\u003econductor\u003c\/strong\u003e (flexible) 2×1.5 mm² for maneuverability and easy connection.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation and black \u003cstrong\u003ePVC\u003c\/strong\u003e sheath: thermal, chemical, and UV resistance.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e for low voltage networks and connections.\u003c\/li\u003e\n  \u003cli\u003eSuitable for \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e use; flame-retardant behavior.\u003c\/li\u003e\n  \u003cli\u003eTypical thermal range: continuous service up to 90 °C in conductor and –15 °C in fixed installation (indicative according to standard and method).\u003c\/li\u003e\n  \u003cli\u003eUsual compliance with UNE \/ IEC power cable standards (IEC 60502-1 \/ UNE 21123-2) and standard commercial CPR (check batch label).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eQuick installation thanks to its flexibility (smaller bending radii and ease in conduits and panels).\u003c\/li\u003e\n  \u003cli\u003eLong service life in solar environments: resistant to UV, humidity, and common chemical agents.\u003c\/li\u003e\n  \u003cli\u003eTotal versatility: equipment connections, lighting, small pumps, distribution panels.\u003c\/li\u003e\n  \u003cli\u003eSafety: XLPE insulation with excellent dielectric strength and robust PVC sheath.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e100 m\u003c\/strong\u003e coil that optimizes cuts and reduces splices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for low voltage photovoltaic installations (connection of inverters\/load centers), outdoor lighting, distribution lines in homes and premises, connections for small pumps, and light automation. Suitable for installation in tray, corrugated conduit, or buried trench with sand bed and marking.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection \/ no. of conductors\u003c\/td\u003e\n\u003ctd\u003e2 × 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV and humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C in conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCPR\u003c\/td\u003e\n\u003ctd\u003eStandard commercial category for RV-K (check coil marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eSuitable for connection of electrical panels, inverters, and small receivers in low voltage solar systems; usable with corrugated conduits, cable ducts, and standard trays. Terminals and accessories are not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 2x1.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e provides safety, durability, and flexibility for professional solar and electrical projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503327969621,"sku":"REVICAB019","price":71.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-2-HILOS.png?v=1762630019"},{"product_id":"manguera-rv-k-2x2-5-mm-100m","title":"RV-K Hose 2x2.5mm² 100m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 2x2.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e is a versatile, robust, and flexible power cable designed for distribution lines, solar equipment connections, lighting, and small machines. Its construction with class 5 copper, XLPE insulation, and black PVC sheath ensures high thermal and mechanical resistance, excellent outdoor performance, and suitability for buried or tray installation.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003e2×2.5 mm²\u003c\/strong\u003e section in class 5 copper for lower voltage drop and easy laying.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE + PVC\u003c\/strong\u003e structure: high dielectric strength and protection against UV, water, and oils.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e suitable for low voltage networks and power connections.\u003c\/li\u003e\n  \u003cli\u003eInstallation in \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e environments; flame retardant.\u003c\/li\u003e\n  \u003cli\u003eTypical operating temperatures: –15 °C (fixed installation) to 90 °C on conductor (continuous).\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e100 m\u003c\/strong\u003e coil for continuous runs and fewer splices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigher current capacity than 1.5 mm² while maintaining high flexibility.\u003c\/li\u003e\n  \u003cli\u003eDurability in solar and outdoor environments: resistant to radiation and humidity.\u003c\/li\u003e\n  \u003cli\u003eVersatility: connections to inverters\/loads, public\/private lighting, pumps, and panels.\u003c\/li\u003e\n  \u003cli\u003eElectrical safety due to its XLPE insulation and robust PVC sheath.\u003c\/li\u003e\n  \u003cli\u003eEasy installation in conduits, cable trays, or trenches thanks to its favorable bending radius.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for power circuits in low voltage photovoltaic systems, powering pumps and water treatment units, outdoor lighting lines, socket circuits, and panel branch circuits. Suitable for runs in cable trays, embedded conduit, or buried ducting with proper protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection \/ number of conductors\u003c\/td\u003e\n\u003ctd\u003e2 × 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV and humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C on conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCPR\u003c\/td\u003e\n\u003ctd\u003eStandard commercial category for RV-K (see batch marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eUsable with standard conduits and accessories (tubes, trays, cable glands, and terminals suitable for 2.5 mm²). Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 2x2.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e offers reliability, safety, and ease of installation for professional solar and electrical projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503328067925,"sku":"REVICAB020","price":106.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-2-HILOS_851ff297-7e9f-4522-87d9-ab8e45a2d81f.png?v=1762630023"},{"product_id":"manguera-rv-k-3x1-5-mm-100m","title":"RV-K Hose 3x1.5mm² 100m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x1.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e is a flexible and robust power cable, designed to reliably meet the low voltage electrical distribution needs in residential, commercial, industrial, and photovoltaic environments. Its construction with class 5 electrolytic copper, XLPE insulation, and black PVC outer sheath makes it a reliable, safe, and durable solution against weather, humidity, and common chemical agents. The 100-meter coil allows for continuous runs with fewer splices, reducing installation time and voltage drops due to unnecessary joints.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 (flexible) copper conductor, 3 × 1.5 mm², which facilitates installation in conduits, trays, and panels.\u003c\/li\u003e\n  \u003cli\u003eCombination of \u003cstrong\u003eXLPE (insulation)\u003c\/strong\u003e and \u003cstrong\u003ePVC (sheath)\u003c\/strong\u003e for high dielectric strength and mechanical protection.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e, suitable for low voltage networks and power connections.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e use; flame retardant and good resistance to UV rays.\u003c\/li\u003e\n  \u003cli\u003eTypical thermal range: up to 90 °C in the conductor during continuous service (depending on installation method).\u003c\/li\u003e\n  \u003cli\u003eMarking and manufacturing in accordance with market reference standards (IEC 60502-1 \/ UNE 21123-2).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAgile installation: its flexibility allows for reduced bending radii and quick passage through conduits.\u003c\/li\u003e\n  \u003cli\u003eDurability in solar environments: UV- and moisture-resistant sheath for outdoor work.\u003c\/li\u003e\n  \u003cli\u003eEnhanced electrical safety due to XLPE insulation, with excellent performance against transient overvoltages.\u003c\/li\u003e\n  \u003cli\u003eTrue versatility: suitable for power circuits, lighting, small motors, and solar equipment connections.\u003c\/li\u003e\n  \u003cli\u003eOptimized cost: \u003cstrong\u003e100 m\u003c\/strong\u003e coil minimizes splices and material waste.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for power and lighting circuits, connections to distribution panels, lines to inverters or auxiliary equipment in photovoltaic systems, connections for medium-low flow pumps, light automation, and general building services. Suitable for installation in trays, embedded conduit, or buried trench with sand bedding and proper marking.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection \/ number of conductors\u003c\/td\u003e\n\u003ctd\u003e3 × 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV and moisture\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C in conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eUsual commercial category for RV-K (check batch marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with standard conduits and accessories: corrugated and rigid pipes, cable trays, cable glands, and terminals for 1.5 mm². Suitable for connection to electrical panels, control equipment, lighting fixtures, and small receivers. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x1.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e is the professional choice for solar and electrical installations seeking reliability, flexibility, and excellent value for money.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503328264533,"sku":"REVICAB021","price":86.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS_160b4074-804c-40f4-85ea-a3b1d15aae4d.png?v=1762630025"},{"product_id":"manguera-rv-k-3x1-5-mm-50m","title":"RV-K Hose 3x1.5mm² 50m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x1.5mm² 50m Black 0.6\/1kV\u003c\/strong\u003e is a flexible power cable designed for agile low voltage work: renovations, panel extensions, branch circuits to solar equipment, and lighting lines. Its class 5 copper conductor provides excellent maneuverability, while the XLPE insulation and black PVC outer sheath ensure mechanical and electrical resistance in demanding environments, both indoors and outdoors or buried. The 50-meter format reduces waste in small projects and facilitates transport.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 copper \u003cstrong\u003econductor\u003c\/strong\u003e (flexible), 3 × 1.5 mm², ideal for conduits with curves and confined spaces.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eDouble protection system XLPE + PVC\u003c\/strong\u003e with high dielectric strength and great resistance to UV and humidity.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e for low voltage networks and service connections.\u003c\/li\u003e\n  \u003cli\u003eSuitable for \u003cstrong\u003eindoor, outdoor, and buried installation\u003c\/strong\u003e; flame-retardant behavior.\u003c\/li\u003e\n  \u003cli\u003eService temperature: up to 90 °C on the conductor continuously (depending on method and grouping).\u003c\/li\u003e\n  \u003cli\u003eCompliance with market reference standards (IEC 60502-1 \/ UNE 21123-2).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003e50 m\u003c\/strong\u003e format: less surplus and better cost control in small installations.\u003c\/li\u003e\n  \u003cli\u003eQuick installation due to favorable bending radius and low rigidity.\u003c\/li\u003e\n  \u003cli\u003eReliability outdoors and in humid areas thanks to the UV- and water-resistant PVC sheath.\u003c\/li\u003e\n  \u003cli\u003eVersatility: suitable for lighting, small pumps, general use outlets, and inverter auxiliaries.\u003c\/li\u003e\n  \u003cli\u003eSafety and extended service life with high-performance XLPE insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003ePerfect for branch circuits to secondary panels, lighting lines, power supply for control equipment, and auxiliary services in low voltage photovoltaic installations. Suitable for installation in corrugated conduit, cable duct, metal tray, or buried with sand bedding and warning tape, following applicable regulations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection \/ no. of conductors\u003c\/td\u003e\n\u003ctd\u003e3 × 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV and humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C on conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eUsual commercial category for RV-K (see reel marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReel length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with standard installation accessories: conduits, cable glands, connectors, and cable trays suitable for 1.5 mm². Suitable for connection to luminaires, small receivers, and electrical panels. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x1.5mm² 50m Black 0.6\/1kV\u003c\/strong\u003e offers the ideal balance between flexibility, safety, and practical format for medium and small-scale projects in professional solar and electrical environments.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503328362837,"sku":"REVICAB022","price":53.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS.png?v=1762630027"},{"product_id":"manguera-rv-k-3x2-5-mm-100m","title":"RV-K Hose 3x2.5mm² 100m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x2.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e is a flexible, robust, and highly versatile power cable for low voltage. Its 2.5 mm² cross-section per conductor offers increased current capacity compared to 1.5 mm², while maintaining high maneuverability in runs with curves or confined spaces. With class 5 electrolytic copper conductor, XLPE insulation, and black PVC outer sheath, it withstands demanding conditions: UV radiation, humidity, oil splashes, and mechanical stress, making it ideal for solar installations, lighting, automation, and power lines in residential, commercial, or industrial environments.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 \u003cstrong\u003ecopper conductor\u003c\/strong\u003e, 3 × 2.5 mm², flexible and with low electrical resistance.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE (insulation) + PVC (sheath)\u003c\/strong\u003e configuration for high dielectric strength and mechanical protection.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e suitable for LV networks and equipment connections.\u003c\/li\u003e\n  \u003cli\u003eSuitable for \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e installation; flame-retardant behavior.\u003c\/li\u003e\n  \u003cli\u003eTypical service temperature: –15 °C (fixed installation) to 90 °C on the conductor in continuous operation.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e100 m\u003c\/strong\u003e coil for long runs, with fewer splices and lower voltage drop at joints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGreater current margin and lower voltage drop than 1.5 mm² while maintaining high flexibility.\u003c\/li\u003e\n  \u003cli\u003eDurability in demanding environments: PVC sheath resistant to \u003cstrong\u003eUV and humidity\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eQuick installation: favorable bending radii and easy passage through conduit or tray.\u003c\/li\u003e\n  \u003cli\u003eElectrical safety thanks to high-performance \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation.\u003c\/li\u003e\n  \u003cli\u003eTotal versatility: power and lighting, small\/medium pumps, branch circuits to panels and inverters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for power circuits in low voltage photovoltaic installations, supply to water treatment plants and irrigation pumps, outdoor\/indoor lighting lines, and branch circuits to distribution panels. Suitable for installation in embedded conduit, cable duct, metal tray, or buried trench with sand bedding and marking, in accordance with applicable standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section \/ number of conductors\u003c\/td\u003e\n\u003ctd\u003e3 × 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV and humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C on conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit, duct, or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eStandard commercial classification for RV-K (check batch marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with rigid and corrugated conduits, cable trays, cable glands, and terminals suitable for 2.5 mm². Useful as a connection to panels, inverters, contactors, and luminaires. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x2.5mm² 100m Black 0.6\/1kV\u003c\/strong\u003e combines safety, durability, and ease of installation for professional solar and electrical projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503328461141,"sku":"REVICAB023","price":128.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS_60447286-b36a-4e0d-a6e8-418bf6b4e236.png?v=1762630030"},{"product_id":"manguera-rv-k-3x2-5-mm-50m","title":"RV-K Hose 3x2.5mm² 50m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x2.5mm² 50m Black 0.6\/1kV\u003c\/strong\u003e is a flexible power cable designed for installations and maintenance where medium-length runs are required without waste. Its 2.5 mm² cross-section balances current capacity and ease of installation, making it ideal for power and lighting lines, branch circuits to panels, supply of pumps, and auxiliary equipment in solar systems. Class 5 copper conductor, XLPE insulation, and black PVC sheath provide reliable protection against weather, moisture, and typical mechanical stresses.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 copper \u003cstrong\u003econductor\u003c\/strong\u003e, 3 × 2.5 mm²: flexible and with low resistance.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE + PVC\u003c\/strong\u003e protection: excellent dielectric strength and resistance to UV and water.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e for low voltage networks and service connections.\u003c\/li\u003e\n  \u003cli\u003eSuitable for \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e use, flame retardant.\u003c\/li\u003e\n  \u003cli\u003eTypical service temperature: up to 90 °C at the conductor in continuous operation.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e50 m\u003c\/strong\u003e coil reduces waste and facilitates transport on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLower voltage drop and higher current capacity than 1.5 mm² in the same flexible format.\u003c\/li\u003e\n  \u003cli\u003eQuick installation: favorable bending radii, ideal for conduits with curves and compact panels.\u003c\/li\u003e\n  \u003cli\u003eHigh durability outdoors thanks to the sheath resistant to \u003cstrong\u003eUV and moisture\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eSafety and reliability due to high-performance \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation.\u003c\/li\u003e\n  \u003cli\u003e50 m format perfect for renovations, repairs, and small extensions without excess stock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for power and lighting circuits in homes, businesses, and light industry, for supplying pool filters, irrigation pumps, aerothermal systems, and auxiliary equipment for photovoltaic inverters. Suitable for installation in embedded or exposed conduit, cable duct, cable tray, and buried trench with sand bed and marking.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section \/ number of conductors\u003c\/td\u003e\n\u003ctd\u003e3 × 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV and moisture\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C at conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit, duct, or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eUsual commercial classification in RV-K (see batch marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with standard conduits, cable glands, connectors, and trays for 2.5 mm². Useful as a service connection to panels, luminaires, small\/medium motors, and auxiliary equipment. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x2.5mm² 50m Black 0.6\/1kV\u003c\/strong\u003e offers the perfect balance between capacity, flexibility, and format for maintenance work and new solar and electrical installations.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503328592213,"sku":"REVICAB024","price":78.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS_8ab9bbdf-cd34-428c-9e8b-4a0a2dc7c6da.png?v=1762630032"},{"product_id":"manguera-rv-k-3x4-mm-50m","title":"RV-K Hose 3x4mm² 50m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x4mm² 50m Black 0.6\/1kV\u003c\/strong\u003e is a flexible power cable designed to reliably withstand higher loads in low voltage applications. Its 4 mm² cross-section per conductor provides optimal current capacity and voltage drop for medium-length runs, while maintaining the maneuverability characteristic of class 5 copper. Thanks to its XLPE insulation and black PVC outer sheath, it reliably resists weather, humidity, ultraviolet radiation, and oil splashes, making it ideal for solar, residential, commercial, and industrial environments.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 copper \u003cstrong\u003econductor\u003c\/strong\u003e (flexible), 3 × 4 mm², ideal for runs with tight bending radii.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE (insulation) + PVC (sheath)\u003c\/strong\u003e architecture with excellent dielectric strength and mechanical protection.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e for low voltage networks and power connections.\u003c\/li\u003e\n  \u003cli\u003eSuitable for \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e installations; flame-retardant behavior.\u003c\/li\u003e\n  \u003cli\u003eTypical thermal regime: up to 90 °C in the conductor during continuous service (depending on installation and grouping method).\u003c\/li\u003e\n  \u003cli\u003eManufactured in accordance with market reference standards (IEC 60502-1 \/ UNE 21123-2) and standard commercial CPR for RV-K.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigher current capacity and lower voltage drop than 2.5 mm², while maintaining great installation flexibility.\u003c\/li\u003e\n  \u003cli\u003eSuperior outdoor durability: PVC resistant to \u003cstrong\u003eUV\u003c\/strong\u003e and \u003cstrong\u003ehumidity\u003c\/strong\u003e for exposed worksites.\u003c\/li\u003e\n  \u003cli\u003eAgile installation: favorable bending radii and easy passage through conduits and loaded trays.\u003c\/li\u003e\n  \u003cli\u003eElectrical safety: \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation with high dielectric strength against transients.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e50 m\u003c\/strong\u003e format optimizes material use for renovations, maintenance, and small extensions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for power and lighting circuits with higher demand, connections to panels and photovoltaic inverters, supply to pumps, water treatment systems, aerothermal units, and small motors. Suitable for installation in embedded or exposed conduit, cable duct, cable tray, and buried trench with sand bedding and marking, complying with current regulations and good cabling practices.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section \/ number of conductors\u003c\/td\u003e\n\u003ctd\u003e3 × 4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV, humidity, and oils\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C in conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit, duct, or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eStandard commercial category for RV-K (see reel marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReel length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with conduits and cable glands suitable for 4 mm², cable trays, and compression or screw terminals for this cross-section. Useful as a connection to panels, variable speed drives, contactors, and solar equipment. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x4mm² 50m Black 0.6\/1kV\u003c\/strong\u003e combines current capacity, flexibility, and environmental resistance for professional electrical and solar installations.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503328788821,"sku":"REVICAB025","price":118.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS_60fe4fae-286e-4fe5-9ce5-b9da08f38751.png?v=1762630036"},{"product_id":"manguera-rv-k-3x6-mm-50m","title":"RV-K Hose 3x6mm² 50m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x6mm² 50m Black 0.6\/1kV\u003c\/strong\u003e is the professional option when higher admissible current and low voltage drop over long runs are required, while maintaining a fast and safe low voltage installation. Each 6 mm² conductor, made of class 5 copper, offers excellent conductivity and flexibility for routing through conduit, tray, or duct with tight bending radii. The XLPE insulation and black PVC sheath provide maximum electrical and mechanical protection against weather, humidity, UV rays, and oil splashes, ensuring a long service life in solar, residential, commercial, and industrial environments.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 5 copper \u003cstrong\u003econductor\u003c\/strong\u003e (flexible), 3 × 6 mm²: larger cross-section for power lines.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE (insulation) + PVC (sheath)\u003c\/strong\u003e assembly with high dielectric strength and mechanical resistance.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e, suitable for LV networks, service entries, and power branches.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e use; flame retardant.\u003c\/li\u003e\n  \u003cli\u003eNormal service temperature: up to 90 °C in the conductor under continuous operation.\u003c\/li\u003e\n  \u003cli\u003eManufactured according to IEC 60502-1 \/ UNE 21123-2 and standard commercial CPR for RV-K cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh current capacity and lower voltage drop compared to 4 mm² and 2.5 mm², ideal for power lines.\u003c\/li\u003e\n  \u003cli\u003eExcellent \u003cstrong\u003eUV and moisture resistance\u003c\/strong\u003e for outdoor installations in photovoltaics.\u003c\/li\u003e\n  \u003cli\u003eEfficient installation: class 5 copper flexibility facilitates routing through demanding conduits.\u003c\/li\u003e\n  \u003cli\u003eSafety and reliability: high-performance \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation for transients and brief overloads.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003e50 m\u003c\/strong\u003e coil reduces waste and simplifies on-site logistics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for supplying inverters, main and secondary panels, pumps and higher power motors, long-distance lighting lines, and branches in low voltage photovoltaic systems. Suitable for installation in recessed or surface conduit, duct, cable tray, and buried trench with sand bedding and marking according to regulations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section \/ number of conductors\u003c\/td\u003e\n\u003ctd\u003e3 × 6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV, moisture, and oils\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C in conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit, duct, or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eStandard commercial category for RV-K (see coil marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with connectors, cable glands, terminals, and conduits sized for 6 mm². Suitable for connections to panels, drives, protections, and power equipment in solar and industrial installations. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 3x6mm² 50m Black 0.6\/1kV\u003c\/strong\u003e offers maximum reliability, current capacity, and environmental resistance for demanding electrical and photovoltaic projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503329050965,"sku":"REVICAB026","price":136.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS_784773ab-bd52-4630-99b3-3dc8010850ec.png?v=1762630037"},{"product_id":"manguera-rv-k-4x2-5-mm-50m","title":"RV-K Hose 4x2.5mm² 50m Black 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 4x2.5mm² 50m Black 0.6\/1kV\u003c\/strong\u003e is a flexible and versatile low voltage power cable, designed for professional installations in solar, residential, commercial, and light industrial applications. It combines class 5 electrolytic copper conductors with XLPE insulation and a black PVC outer sheath, offering high dielectric strength, excellent mechanical resistance, and durability for outdoor use. The 50-meter format is ideal for medium-sized projects and maintenance, reducing waste and facilitating transport.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfiguration \u003cstrong\u003e4×2.5 mm²\u003c\/strong\u003e: suitable for \u003cstrong\u003ethree-phase (3F+PE)\u003c\/strong\u003e or single-phase (F+N+PE+reserve).\u003c\/li\u003e\n  \u003cli\u003eClass 5 (flexible) \u003cstrong\u003ecopper conductor\u003c\/strong\u003e that facilitates installation through conduit, cable tray, or duct.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eXLPE (insulation) + PVC (sheath)\u003c\/strong\u003e: excellent dielectric strength and protection against impacts and abrasion.\u003c\/li\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e, suitable for low voltage networks and equipment connections.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eindoor, outdoor, and buried\u003c\/strong\u003e use; sheath resistant to UV rays, moisture, and oil splashes.\u003c\/li\u003e\n  \u003cli\u003eTypical thermal rating: up to 90 °C at the conductor in continuous service (depending on installation method).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTrue versatility: a single hose for three-phase distribution, motors, pumps, or single-phase branches with earth.\u003c\/li\u003e\n  \u003cli\u003eQuick installation due to high flexibility and favorable bending radii in conduits and compact panels.\u003c\/li\u003e\n  \u003cli\u003eHigher current capacity and lower voltage drop than 1.5 mm² while maintaining maneuverability.\u003c\/li\u003e\n  \u003cli\u003eReliability in solar environments: black PVC sheath resistant to \u003cstrong\u003eUV\u003c\/strong\u003e and \u003cstrong\u003emoisture\u003c\/strong\u003e for outdoor and buried use.\u003c\/li\u003e\n  \u003cli\u003eLong service life: \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation with excellent performance against brief overloads and transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRecommended for three-phase supply of small\/medium motors and pumps, branches to panels, aerothermal systems, pool filtration systems, and power lines in low voltage photovoltaic installations. In single-phase, it allows phase, neutral, and earth to be carried in a single conduit. Suitable for cable tray, duct, embedded or surface-mounted conduit, and buried trench with sand bed and signaling according to regulations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRV-K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection \/ no. of conductors\u003c\/td\u003e\n\u003ctd\u003e4 × 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 electrolytic copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (cross-linked polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eBlack PVC, resistant to UV, moisture, and oils\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C at conductor (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, outdoor, buried, conduit, duct, or tray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eStandard commercial classification for RV-K (check batch marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCoil length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReference standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60502-1 \/ UNE 21123-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with corrugated and rigid conduits, cable trays, cable glands, and terminals for 2.5 mm². Useful as a connection to panels, drives, contactors, luminaires, and low voltage solar equipment. Accessories not included.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRV-K Hose 4x2.5mm² 50m Black 0.6\/1kV\u003c\/strong\u003e provides safety, flexibility, and environmental resistance for reliable electrical distribution in solar and general power projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503329280341,"sku":"REVICAB027","price":100.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-4-HILOS.png?v=1762630040"},{"product_id":"manguera-rz1-k-2x10-mm-libre-halogeno","title":"RZ1-K Green Hose 2x10mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 2x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable for low voltage that combines safety, durability, and ease of installation. Its RZ1-K (AS) design integrates class 5 copper conductors for easy routing, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C) with excellent thermal performance, and a halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath that reduces smoke opacity and toxicity. Complies with \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, making it suitable for public buildings, industry, and photovoltaic plant balance of system on the AC side.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e · Test voltage: \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConductors: \u003cstrong\u003e2×10 mm²\u003c\/strong\u003e class 5 copper (flexible).\u003c\/li\u003e\n\u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e · Sheath: \u003cstrong\u003eLSZH\u003c\/strong\u003e (halogen-free and low smoke emission).\u003c\/li\u003e\n\u003cli\u003eConductor service: \u003cstrong\u003e90 °C\u003c\/strong\u003e (short-circuit 250 °C \/ 5 s).\u003c\/li\u003e\n\u003cli\u003eInstallation: \u003cstrong\u003eindoor, outdoor, tray, conduit, or buried\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eManufacturing standard: \u003cstrong\u003eUNE 21123-4\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPR safety\u003c\/strong\u003e for public spaces: very low smoke opacity and acidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower voltage drop\u003c\/strong\u003e compared to smaller cross-sections over medium\/long runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior handling\u003c\/strong\u003e thanks to the flexible class 5 conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e in buildings, industry, and solar plants (AC distribution).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong service life\u003c\/strong\u003e due to the thermal and mechanical stability of XLPE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eFeeders and branch circuits in panels, service lines in buildings and warehouses, connections and AC distribution in photovoltaic installations. Suitable for conduit, tray, or trench routing, complying with REBT and ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e2 (without protective conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e2 × 10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.9 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with cable glands, ferrules, and terminals for 10 mm²; suitable for standard conduits and direct burial. Size protections and cross-section according to REBT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Hose 2x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e ensures safe and reliable electrical distribution in demanding LV projects.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503329509717,"sku":"REVICAB028","price":5.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-2-HILOS-RZ1.png?v=1762630042"},{"product_id":"manguera-rz1-k-2x16-mm-libre-halogeno","title":"RZ1-K Green Hose 2x16mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 2x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a large-section multipolar cable for low voltage, designed for high-demand power supply and branch circuits in buildings, industry, and solar plants. Its construction with class 5 copper conductors provides flexibility and reduced bending radii; the \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation ensures continuous service at 90 °C and the \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath guarantees low emission of smoke and corrosive gases. Certified \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, it provides maximum safety in public spaces.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e · Test: \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConductors: \u003cstrong\u003e2×16 mm²\u003c\/strong\u003e class 5 copper.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C) and \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath (halogen-free).\u003c\/li\u003e\n\u003cli\u003eInstallation: \u003cstrong\u003eindoor, outdoor, tray, conduit, or buried\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eStandard: \u003cstrong\u003eUNE 21123-4\u003c\/strong\u003e · CPR: \u003cstrong\u003eCca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimal voltage drop\u003c\/strong\u003e over long runs and high loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced safety\u003c\/strong\u003e against fire due to its LSZH sheath (low smoke opacity\/toxicity).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy installation\u003c\/strong\u003e thanks to the flexibility of class 5 conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile\u003c\/strong\u003e: buildings, industry, infrastructure, and AC distribution in photovoltaics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e characteristic of XLPE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRisers, main and plant panel feeds, service entries, and internal LV networks; AC distribution in solar plants when a larger section is required due to current or distance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e2 (without PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSection\u003c\/td\u003e\n\u003ctd\u003e2 × 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.21 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 16 mm² terminals and ferrules, metric cable glands, and standardized conduits. Size protections and routes according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRZ1-K Green Hose 2x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e offers CPR safety and superior electrical performance for main low voltage lines.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503329673557,"sku":"REVICAB029","price":8.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-2-HILOS-RZ1_01618912-c5de-400c-b510-285d83d5b832.png?v=1762630045"},{"product_id":"manguera-rz1-k-2x6-mm-libre-halogeno","title":"RZ1-K Green Hose 2x6mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 2x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible low voltage multipolar cable designed for power supply and branch circuits in buildings, industry, and solar installations (AC side). Its RZ1-K (AS) construction combines class 5 electrolytic copper conductors with \u003cstrong\u003eXLPE\u003c\/strong\u003e (cross-linked polyethylene) insulation and \u003cstrong\u003eLSZH\u003c\/strong\u003e (halogen-free) sheath, ensuring excellent thermal performance, high durability, and \u003cstrong\u003every low emission of smoke\u003c\/strong\u003e and corrosive gases in case of fire. It complies with \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, a common requirement in public spaces and civil works. Thanks to its flexibility and reduced bending radius, it facilitates routing in conduit, tray, or trench, providing fast installation and reliable service.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage: \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConductors: \u003cstrong\u003e2 × 6 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n\u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e 90 °C; \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath.\u003c\/li\u003e\n\u003cli\u003eCertified fire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMultipurpose use: indoor, outdoor, in tray, conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSuitable for photovoltaic plant balance of system (AC distribution) and general LV uses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nSuperior \u003cstrong\u003esafety\u003c\/strong\u003e: low smoke opacity and toxicity; halogen-free.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e: XLPE with high thermal and dielectric stability at 90 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManageability\u003c\/strong\u003e: class 5 conductors that speed up laying and bends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: 2×6 mm² cross-section suitable for limiting voltage drop in typical runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e: suitable for service networks, panels, lighting, and connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003ePower supply and branch circuits in residential and commercial buildings, service lines in warehouses, AC distribution in solar plants, circuits in tray or conduit, and buried runs complying with REBT and ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e2 (without protective conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e2 × 6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eLSZH halogen-free, low smoke emission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter (custom length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with metric cable glands, ferrules and terminals for 6 mm², and standard conduits in tray, tube, or trench. Size protections and cross-section according to REBT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 2x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e offers CPR safety, flexibility, and long service life for reliable low voltage distribution.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503329870165,"sku":"REVICAB030","price":3.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-2-HILOS-RZ1_ef5e7f1c-894c-4b1a-8988-cd3afed2ffcb.png?v=1762630047"},{"product_id":"manguera-rz1-k-3x1-5-mm-100m-libre-halogeno","title":"RZ1-K Green Hose 3x1.5mm² 100M Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x1.5mm² 100M Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable designed for low voltage distribution and control circuits where CPR performance and ease of installation are required. With three class 5 copper conductors of 1.5 mm², \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation, and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath, it provides fire safety (low smoke opacity and toxicity) and excellent thermal performance at 90 °C. Supplied in a \u003cstrong\u003e100 m roll\u003c\/strong\u003e, it is a practical format for new construction, renovations, and maintenance in homes, offices, commercial premises, industry, and photovoltaic plant balance of system (AC).\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage: \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConductors: \u003cstrong\u003e3 × 1.5 mm²\u003c\/strong\u003e class 5 copper (flexible).\u003c\/li\u003e\n\u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e 90 °C; \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath.\u003c\/li\u003e\n\u003cli\u003eFire reaction certification: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIndoor, outdoor, tray, conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e application according to UNE 21123-4.\u003c\/li\u003e\n\u003cli\u003eExcellent handling and small bending radii for quick installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding safety\u003c\/strong\u003e: very low smoke opacity and zero halogen emission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e and extended service life thanks to XLPE insulation at 90 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProductivity\u003c\/strong\u003e: 100 m roll reduces splices and assembly time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e: suitable for lighting, sockets, control, and general services in LV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e with standard REBT fittings and conduits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eLighting and power circuits in residential and tertiary buildings, distribution and control in industrial facilities, auxiliary AC lines in solar plants, wiring in trays, corrugated conduits, or trenches when CPR Cca is required by regulations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e3 × 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eLSZH halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSold by the meter (custom length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with metric cable glands, ferrules, and terminals for 1.5 mm², as well as with standardized conduits in tray, tube, or trench. Size protections and cross-section according to REBT and voltage drop calculations.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x1.5mm² 100M Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, manageability, and a professional format for reliable and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330034005,"sku":"REVICAB031","price":102.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1.png?v=1762630049"},{"product_id":"manguera-rz1-k-3x1-5-mm-50m-libre-halogeno","title":"RZ1-K Green Hose 3x1.5mm² 50M Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x1.5mm² 50M Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible low-voltage multipolar cable designed for safe installations in residential, commercial, industrial, and photovoltaic plant balance of system (AC side). Its triple class 5 copper conductor facilitates installation in conduits and trays; the \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation ensures thermal stability at 90 °C and the \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath minimizes the emission of smoke and corrosive gases. With \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e certification, it meets safety requirements for public spaces and civil works.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFlexible \u003cstrong\u003eclass 5 copper\u003c\/strong\u003e conductors, cross-section 3×1.5 mm².\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation and \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath (halogen-free, low smoke emission).\u003c\/li\u003e\n  \u003cli\u003eContinuous conductor service at \u003cstrong\u003e90 °C\u003c\/strong\u003e (short-circuit 250 °C\/5 s).\u003c\/li\u003e\n  \u003cli\u003eInstallation indoors, outdoors, on tray, in conduit, or buried.\u003c\/li\u003e\n  \u003cli\u003eProfessional format: \u003cstrong\u003e50 m roll\u003c\/strong\u003e for construction and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCPR Safety\u003c\/strong\u003e: very low smoke opacity and acidity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior manageability\u003c\/strong\u003e due to class 5 conductor and reduced bending radius.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e for lighting, socket, control, and general service circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e and extended service life thanks to XLPE insulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProductivity\u003c\/strong\u003e: the 50 m roll reduces splices and installation time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for lighting and power wiring in homes, offices, and commercial premises; distribution and control in warehouses; auxiliary lines in solar installations on alternating current. Suitable for tray, corrugated conduit, or buried ducts in accordance with REBT\/ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e3 (without protective conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e3 × 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 12.1 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 m roll\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with cable glands, ferrules, and terminals for 1.5 mm², as well as with standardized conduits (tube, tray, trench). Select protections and cross-section according to REBT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x1.5mm² 50M Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, flexibility, and performance for reliable and durable low-voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330263381,"sku":"REVICAB032","price":63.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_8d939ca8-f29b-4e91-8ab3-0f38931ddf8b.png?v=1762630052"},{"product_id":"manguera-rz1-k-3x10-mm-libre-halogeno","title":"RZ1-K Green Hose 3x10mm² Halogen-Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable with a large cross-section for high-demand power supply and branch circuits in low voltage. It is designed for building, industry, and photovoltaic plant balance of system (AC side), where maximum safety and minimal voltage drop are required. Its RZ1-K (AS) construction integrates \u003cstrong\u003eclass 5 copper\u003c\/strong\u003e conductors for agile installation, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation rated for 90 °C service, and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath with very low smoke opacity and toxicity. The \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e classification allows its use in public spaces and demanding civil works. It is supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e to precisely match the required cable length.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eConductors: \u003cstrong\u003e3 × 10 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eInsulation \u003cstrong\u003eXLPE\u003c\/strong\u003e (90 °C) and \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath.\u003c\/li\u003e\n  \u003cli\u003eVersatile installation: indoor, outdoor, tray, conduit, or buried.\u003c\/li\u003e\n  \u003cli\u003eSold \u003cstrong\u003eby the meter\u003c\/strong\u003e to optimize costs and avoid splices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReduced voltage drop\u003c\/strong\u003e compared to smaller cross-sections over medium\/long runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCPR safety\u003c\/strong\u003e with low smoke emission and halogen-free.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEase of handling\u003c\/strong\u003e and favorable bending radii due to class 5 conductor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e inherent to XLPE in continuous service at 90 °C.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible supply\u003c\/strong\u003e thanks to sale by the meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eMain risers and power feeds, branch circuits to panels, service entries, and internal low voltage networks. In photovoltaics, ideal for AC distribution (from inverters to panels\/CT) when a larger cross-section is required due to current or distance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e3 × 10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.91 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReaction to fire (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold \u003cstrong\u003eby the meter\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts terminals and ferrules for 10 mm², metric cable glands, and standard conduits. Select protection devices and cross-section according to REBT, permissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e offers CPR safety, high current capacity, and custom supply for low voltage power lines.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330394453,"sku":"REVICAB033","price":8.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_b4a392e2-16fe-4785-9ef2-2fee4f720c22.png?v=1762630054"},{"product_id":"manguera-rz1-k-3x16-mm-libre-halogeno","title":"RZ1-K Green Hose 3x16mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable with a large cross-section designed for high-demand power supplies and branches in low voltage. Its RZ1-K (AS) construction combines three class 5 electrolytic copper conductors—which facilitate routing and bending in trays or conduits—with \u003cstrong\u003eXLPE\u003c\/strong\u003e (cross-linked polyethylene) insulation and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath, with very low smoke opacity and toxicity. With a fire reaction classification of \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, it is ideal for public buildings, civil works, industry, and photovoltaic plant balance of system (AC side). It is supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e to adjust the exact length of the installation, optimizing costs and reducing splices.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage: \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConductors: \u003cstrong\u003e3 × 16 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n\u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e for continuous service at 90 °C and excellent dielectric strength.\u003c\/li\u003e\n\u003cli\u003eSheath: \u003cstrong\u003eLSZH\u003c\/strong\u003e (halogen-free), low emission of smoke and corrosive gases.\u003c\/li\u003e\n\u003cli\u003eCertification: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e for applications with safety requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation: indoor, outdoor, in tray, conduit, or \u003cstrong\u003eburied\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimal voltage drop\u003c\/strong\u003e compared to smaller cross-sections, ideal for long runs or concentrated loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior safety\u003c\/strong\u003e: low opacity\/toxicity smoke and zero halogen emission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong service life\u003c\/strong\u003e due to the thermal and mechanical stability of XLPE in continuous service at 90 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutstanding manageability\u003c\/strong\u003e thanks to class 5 conductors and favorable bending radii.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e in building, industry, and solar installations (AC distribution, panels, and connections).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eMain power supplies and branches for main panels, riser columns, connections from transformer stations, internal networks of buildings and warehouses, and \u003cem\u003eAC\u003c\/em\u003e distribution in solar plants (from inverters to panels\/transformer center). Suitable for installation in tray, corrugated conduit, buried duct, or outdoors, complying with REBT and ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e3 × 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C in service \/ 250 °C, 5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePolyolefin \u003cstrong\u003eLSZH\u003c\/strong\u003e, halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.21 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSold by the meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts 16 mm² ferrules\/terminals, metric cable glands, and standard conduits (tube, tray, trench). Size protections and cross-section according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, high current capacity, and custom supply for reliable and durable low voltage cabling.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330591061,"sku":"REVICAB034","price":9.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_9dae9bcc-d072-4020-98e6-5971b40c0e97.png?v=1762630056"},{"product_id":"manguera-rz1-k-3x2-5-mm-100m-libre-halogeno","title":"RZ1-K Green Hose 3x2.5mm² 100M Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x2.5mm² 100M Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable designed for distribution circuits and general services in low voltage applications that require maximum safety and reliability. It incorporates three class 5 copper conductors of 2.5 mm² with \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (service at 90 °C) and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath, which drastically reduces the opacity and toxicity of smoke in case of fire. Its \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e certification makes it suitable for public buildings, unique buildings, industry, and photovoltaic plant balance of system (AC side). The \u003cstrong\u003e100 m roll\u003c\/strong\u003e format streamlines new construction, renovations, and maintenance, minimizing splices and installation time.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eConductors: \u003cstrong\u003e3 × 2.5 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eInsulation: \u003cstrong\u003eXLPE\u003c\/strong\u003e (90 °C); sheath: \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free.\u003c\/li\u003e\n  \u003cli\u003eFire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e (low smoke opacity and acidity).\u003c\/li\u003e\n  \u003cli\u003eVersatile use: indoor, outdoor, on tray, in conduit, or buried.\u003c\/li\u003e\n  \u003cli\u003eContinuous \u003cstrong\u003e100 m roll\u003c\/strong\u003e for clean runs without splices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety\u003c\/strong\u003e in buildings and civil works: very low smoke opacity\/toxicity, halogen-free.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuick installation\u003c\/strong\u003e: class 5 conductors with favorable bending radii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e and balance between current capacity and cost in 2.5 mm².\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e thanks to XLPE insulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e with standardized REBT fittings and conduits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eLighting and power circuits, general outlets in residential and tertiary buildings, distribution and control in warehouses, auxiliary lines in solar installations (AC), and runs in tray, corrugated conduit, or buried ducts where CPR Cca is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection\u003c\/td\u003e\n\u003ctd\u003e3 × 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C service \/ 250 °C, 5 s short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePolyolefin \u003cstrong\u003eLSZH\u003c\/strong\u003e, halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 7.41 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 m roll\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts terminals and ferrules for 2.5 mm², metric cable glands, and standardized conduits (tube, tray, trench). Select protections and section according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x2.5mm² 100M Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, flexibility, and a professional format for reliable and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330754901,"sku":"REVICAB035","price":148.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_5adabbfa-2963-4b4e-be97-b935148bbd26.png?v=1762630060"},{"product_id":"manguera-rz1-k-3x2-5-mm-50m-libre-halogeno","title":"RZ1-K Green Hose 3x2.5mm² 50M Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x2.5mm² 50M Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable for distribution circuits and general services in low voltage. Its RZ1-K (AS) construction combines class 5 copper conductors with \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C) and a halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath, achieving very low smoke opacity and toxicity in case of fire. It complies with \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, making it suitable for public buildings, special buildings, industry, and photovoltaic plant balance of system (AC side). The \u003cstrong\u003e50 m roll\u003c\/strong\u003e format reduces splices and speeds up on-site installation.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e and test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eConductors: \u003cstrong\u003e3 × 2.5 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C continuous; 250 °C\/5 s in short circuit).\u003c\/li\u003e\n  \u003cli\u003eHalogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eFire reaction classification: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eInstallation: indoor, outdoor, on tray, in conduit, or buried duct.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCPR safety\u003c\/strong\u003e in buildings and civil works, with low opacity and acidity smoke.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgile installation\u003c\/strong\u003e thanks to its great flexibility and favorable bending radii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e in 2.5 mm² for power circuits, sockets, and lighting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e due to XLPE insulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e50 m roll\u003c\/strong\u003e: fewer splices, greater reliability of the wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eLighting and power circuits in residential and tertiary buildings, distribution and control in industrial facilities, auxiliary \u003cem\u003eAC\u003c\/em\u003e lines in solar installations. Suitable for tray, corrugated conduit, or trench according to REBT\/ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection\u003c\/td\u003e\n\u003ctd\u003e3 × 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 7.41 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 m roll\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with metric cable glands and terminals for 2.5 mm²; suitable for standardized conduits (tube, tray, trench). Size protections and section according to REBT and admissible currents.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x2.5mm² 50M Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, flexibility, and a practical format for reliable and durable LV wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330853205,"sku":"REVICAB036","price":84.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_9f2cd097-bcd9-4297-b8d4-2ad8e97c1a63.png?v=1762630063"},{"product_id":"manguera-rz1-k-3x4-mm-libre-halogeno","title":"RZ1-K Green Hose 3x4mm² Halogen-Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x4mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable designed for power circuits and general services in low voltage applications that require high safety and reliability. It integrates three class 5 electrolytic copper conductors, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (service at 90 °C), and a halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath, minimizing the emission of smoke and corrosive gases. Certified \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, it is suitable for residential, tertiary, industrial, and photovoltaic plant balance of system (\u003cem\u003eAC\u003c\/em\u003e). It is supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e to precisely adjust the cable length and reduce costs.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eConductors: \u003cstrong\u003e3 × 4 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eInsulation \u003cstrong\u003eXLPE\u003c\/strong\u003e 90 °C · Halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath.\u003c\/li\u003e\n  \u003cli\u003eFire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eInstallation indoors, outdoors, on tray, in conduit, or buried duct.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSold by the meter\u003c\/strong\u003e to avoid splices and optimize materials.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreater capacity\u003c\/strong\u003e than 2.5 mm², with \u003cstrong\u003elower voltage drop\u003c\/strong\u003e over medium distances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced safety\u003c\/strong\u003e: low smoke opacity\/toxicity, halogen-free.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutstanding manageability\u003c\/strong\u003e due to class 5 conductor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e characteristic of XLPE.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply flexibility\u003c\/strong\u003e as it is sold by the meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eDistribution and branch circuits in buildings and warehouses, supply to panels, service lines, and auxiliary circuits in solar plants (AC side). Suitable for trays, corrugated conduits, or trenches, complying with REBT and ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSection\u003c\/td\u003e\n\u003ctd\u003e3 × 4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 4.61 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eThermal range\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSold by the meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts ferrules\/terminals for 4 mm², metric cable glands, and standardized conduits. Size protections and section according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x4mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e offers CPR safety, excellent manageability, and custom supply for reliable and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503330951509,"sku":"REVICAB037","price":3.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_9a90d598-2b81-40f9-a9fb-f765719a0a60.png?v=1762630064"},{"product_id":"manguera-rz1-k-3x6-mm-libre-halogeno","title":"RZ1-K Green Hose 3x6mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable designed for low voltage power supply and distribution where safety, durability, and ease of installation are priorities. Its RZ1-K (AS) design combines three class 5 electrolytic copper conductors, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation that allows continuous service at 90 °C, and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath with very low smoke opacity and toxicity in case of fire. It meets the demanding fire reaction standard \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, making it ideal for public buildings, civil works, industry, and photovoltaic plant balance of system on the AC side. It is supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e, so you can adjust the exact length of the run and avoid unnecessary splices.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e and test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e for low voltage networks.\u003c\/li\u003e\n  \u003cli\u003eThree \u003cstrong\u003eclass 5 copper\u003c\/strong\u003e conductors (high flexibility) with 3×6 mm² cross-section.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C in service; 250 °C\/5 s in short circuit).\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath: low emission of smoke and corrosive gases.\u003c\/li\u003e\n  \u003cli\u003eFire reaction classification \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eVersatile installation: indoor, outdoor, in tray, conduit, or buried duct.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced safety\u003c\/strong\u003e in buildings and high-traffic areas: low opacity\/toxicity smoke and halogen-free.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower voltage drop\u003c\/strong\u003e compared to smaller cross-sections thanks to 6 mm² per conductor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuick installation\u003c\/strong\u003e due to the flexibility of class 5 copper and favorable bending radii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e of XLPE, stable at 90 °C in continuous service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCost optimization\u003c\/strong\u003e as it is sold \u003cstrong\u003eby the meter\u003c\/strong\u003e, avoiding waste and splices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eThe 3×6 mm² hose is suitable for power and distribution circuits in homes, commercial buildings, and industrial warehouses; supply to sectional panels; service lines in parking lots; and, in photovoltaics, for \u003cem\u003eAC\u003c\/em\u003e distribution between inverters and panels, or between panels and the transformer station when the runs and currents require this cross-section. Suitable for installation in tray, corrugated conduit, or trench, in compliance with REBT and ITC-BT.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e3 (without protective conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e3 × 6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.30 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSold by the meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with 6 mm² ferrules\/terminals, metric cable glands, and standard conduits (pipe, tray, trench). Size protections, admissible current, and voltage drop according to REBT\/ITC-BT and installation conditions.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 3x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, flexibility, and resistance for reliable and durable low voltage wiring in residential, commercial, industrial, and solar applications.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503331049813,"sku":"REVICAB038","price":4.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-3-HILOS-RZ1_ddaa90cf-7f28-4e80-8692-cbf0414f84d5.png?v=1762630069"},{"product_id":"manguera-rz1-k-4x1-5-mm-100m-libre-halogeno","title":"RZ1-K Green Hose 4x1.5mm² 100M Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x1.5mm² 100M Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable designed for low voltage distribution and control where safety, reliability, and quick installation are required. Its four class 5 electrolytic copper conductors provide great flexibility and favorable bending radii; the \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation ensures thermal stability at 90 °C and the \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath drastically reduces smoke opacity and toxicity in case of fire. With \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e certification, it is suitable for residential buildings, offices, public spaces, industry, and photovoltaic plant balance of system on the AC side. The \u003cstrong\u003e100 m roll\u003c\/strong\u003e format allows for continuous runs with fewer splices, optimizing installation time and costs.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e and test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFour \u003cstrong\u003eclass 5 copper\u003c\/strong\u003e conductors (high flexibility), cross-section 4×1.5 mm².\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation (90 °C in service; 250 °C\/5 s in short circuit).\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath: low smoke emission and corrosivity.\u003c\/li\u003e\n  \u003cli\u003eFire reaction \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e for safety-demanding environments.\u003c\/li\u003e\n  \u003cli\u003eInstallation indoors, outdoors, on tray, in conduit, or buried duct.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety\u003c\/strong\u003e in buildings and civil works: low opacity and toxicity smoke, halogen-free.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProductivity\u003c\/strong\u003e on site: \u003cstrong\u003e100 m roll\u003c\/strong\u003e reduces splices and failure points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior manageability\u003c\/strong\u003e due to class 5 conductor and optimized diameter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatility\u003c\/strong\u003e for lighting, sockets, control, switching, and auxiliary \u003cem\u003eAC\u003c\/em\u003e in PV.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e of XLPE in continuous service at 90 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for lighting and power circuits in residential and commercial buildings, distribution and control in industrial facilities, general and auxiliary service lines in photovoltaic installations (\u003cem\u003eAC\u003c\/em\u003e), as well as wiring in cable trays, corrugated conduits, exposed ducts, or trenches, in compliance with current regulations (REBT\/ITC-BT).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eManufacturing standard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e4 × 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 12.1 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE (90 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 m roll\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with cable glands and terminals for 1.5 mm², as well as with standardized conduits (tube, tray, trench). Select protections and cross-section according to REBT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x1.5mm² 100M Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, manageability, and professional format for reliable, organized, and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503331148117,"sku":"REVICAB039","price":129.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-4-HILOS-RZ1.png?v=1762630072"},{"product_id":"manguera-rz1-k-4x10-mm-libre-halogeno","title":"RZ1-K Green Hose 4x10mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable designed for low voltage power and control lines. With four class 5 copper conductors, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation, and \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath, it offers fire safety (low smoke opacity and toxicity) and high thermal durability at 90 °C. Its \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e classification makes it suitable for public buildings, industry, and photovoltaic plant balance of system (AC side). It is supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e to optimize costs and reduce splicing.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage: 0.6\/1 kV; test voltage: 3.5 kV.\u003c\/li\u003e\n  \u003cli\u003eConductors: 4 × 10 mm² class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eXLPE insulation (90 °C in service; 250 °C\/5 s in short circuit).\u003c\/li\u003e\n  \u003cli\u003eLSZH halogen-free sheath, low smoke emission.\u003c\/li\u003e\n  \u003cli\u003eFire reaction: CPR Cca-s1b,d1,a1 for maximum safety.\u003c\/li\u003e\n  \u003cli\u003eInstallation: indoor, outdoor, tray, conduit, or buried.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLower voltage drop over medium\/long runs compared to smaller cross-sections.\u003c\/li\u003e\n  \u003cli\u003eGreat manageability due to class 5 conductor and favorable bending radii.\u003c\/li\u003e\n  \u003cli\u003eEvacuation safety: low opacity, halogen-free smoke.\u003c\/li\u003e\n  \u003cli\u003eProlonged service life thanks to XLPE insulation.\u003c\/li\u003e\n  \u003cli\u003eCustom supply: sold by the meter to fit the project.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRisers, main and branch feeds to panels, service lines in buildings and industry, and \u003cem\u003eAC\u003c\/em\u003e distribution in solar plants (from inverters to panels\/CT) when a larger cross-section is required due to current or distance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e4 × 10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.91 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage \/ test\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV · 3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s sc)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eLSZH, halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts ferrules\/terminals for 10 mm², metric cable glands, and standard conduits (tube, tray, trench). Size protections and cross-section according to REBT\/ITC-BT, admissible currents, and voltage drop.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x10mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e provides CPR safety, current capacity, and custom supply for reliable and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503331246421,"sku":"REVICAB040","price":8.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-4-HILOS-RZ1_bb4825a6-3e3d-47de-9728-53567f55063b.png?v=1762630074"},{"product_id":"manguera-rz1-k-4x16-mm-libre-halogeno","title":"RZ1-K Green Hose 4x16mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable with a large cross-section for power supply and branch circuits with high currents in low voltage. It integrates four class 5 copper conductors that facilitate installation, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation for continuous service at 90 °C, and a halogen-free \u003cstrong\u003eLSZH\u003c\/strong\u003e sheath, minimizing smoke opacity and toxicity. With \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, it meets safety requirements for public buildings, industry, and infrastructure, as well as photovoltaic plant balance of system (AC side). It is offered \u003cstrong\u003eby the meter\u003c\/strong\u003e to precisely match the required cable length.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage 0.6\/1 kV; test voltage 3.5 kV.\u003c\/li\u003e\n  \u003cli\u003eConductors: 4 × 16 mm² class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eXLPE insulation (90 °C) and halogen-free LSZH sheath.\u003c\/li\u003e\n  \u003cli\u003eFire reaction: CPR Cca-s1b,d1,a1.\u003c\/li\u003e\n  \u003cli\u003eIndoor, outdoor, tray, conduit, or buried installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimal voltage drop\u003c\/strong\u003e and excellent current capacity for long runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced safety\u003c\/strong\u003e: low smoke opacity\/toxicity and zero halogen emission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior manageability\u003c\/strong\u003e compared to rigid conductors thanks to class 5.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e due to XLPE insulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply flexibility\u003c\/strong\u003e as it is sold by the meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eRisers, main and plant panel feeds, connections from transformer stations, low voltage internal networks, and \u003cem\u003eAC\u003c\/em\u003e distribution in solar plants (from inverters to panels\/transformer stations) when currents or distances require 16 mm² per conductor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e4 × 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 1.21 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated voltage \/ test\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV · 3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eHalogen-free LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003eSold by the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts ferrules\/terminals for 16 mm², metric cable glands, and standard conduits. Size protections and cross-section according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x16mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, high current capacity, and custom supply for robust and durable low voltage cabling.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503331344725,"sku":"REVICAB041","price":12.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-4-HILOS-RZ1_e6df53ea-2ef7-4243-a41d-fe12a1c2134c.png?v=1762630077"},{"product_id":"manguera-rz1-k-4x4-mm-libre-halogeno","title":"RZ1-K Green Hose 4x4mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x4mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable for low voltage distribution and control circuits with high safety requirements. It integrates four class 5 copper conductors that facilitate installation in conduit and tray, \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation for continuous service at 90 °C, and a \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath with very low smoke opacity and toxicity. With \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e classification, it is suitable for residential, tertiary, industrial, and photovoltaic plant balance of system (AC side). Supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e to precisely adjust the installation length and minimize splices.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFour \u003cstrong\u003eclass 5 copper\u003c\/strong\u003e conductors, 4×4 mm² cross-section (high flexibility).\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eXLPE\u003c\/strong\u003e insulation 90 °C and \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath.\u003c\/li\u003e\n  \u003cli\u003eFire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, low emission of smoke and corrosive gases.\u003c\/li\u003e\n  \u003cli\u003eIndoor, outdoor, tray, conduit, or buried installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigher capacity\u003c\/strong\u003e than 3×2.5 mm² and \u003cstrong\u003elower voltage drop\u003c\/strong\u003e over medium distances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior handling\u003c\/strong\u003e due to class 5 flexible conductor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced safety\u003c\/strong\u003e in buildings and civil works (LSZH, CPR Cca).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e thanks to XLPE.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCustom supply\u003c\/strong\u003e: sold by the meter to optimize costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003eLow voltage distribution, panel supply, control, and general services in residential, office, and industrial settings. In photovoltaics, suitable for auxiliary \u003cem\u003eAC\u003c\/em\u003e distribution and service lines with CPR requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e4 × 4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 4.61 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated \/ test voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV · 3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSold by the meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eAccepts ferrules\/terminals for 4 mm², metric cable glands, and standardized conduits (tube, tray, trench). Size protections and currents according to REBT\/ITC-BT and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x4mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e combines CPR safety, flexibility, and custom supply for reliable and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503331508565,"sku":"REVICAB042","price":5.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-4-HILOS-RZ1_c2a524e0-0b2b-4526-acd9-c2673676e91f.png?v=1762630078"},{"product_id":"manguera-rz1-k-4x6-mm-libre-halogeno","title":"RZ1-K Green Hose 4x6mm² Halogen Free 0.6\/1kV","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e is a flexible multipolar cable with a larger cross-section for low voltage distributions and connections with high demand. Its four class 5 copper conductors ensure great manageability; the \u003cstrong\u003eXLPE\u003c\/strong\u003e insulation provides thermal stability up to 90 °C and the \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath offers maximum safety with very low smoke opacity\/toxicity. Certified \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e, it is suitable for residential, tertiary, industrial, and infrastructure applications, as well as for photovoltaic plant balance of system (AC side). Supplied \u003cstrong\u003eby the meter\u003c\/strong\u003e to adjust the length of the run.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated voltage \u003cstrong\u003e0.6\/1 kV\u003c\/strong\u003e; test voltage \u003cstrong\u003e3.5 kV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eConductors: \u003cstrong\u003e4 × 6 mm²\u003c\/strong\u003e class 5 copper (high flexibility).\u003c\/li\u003e\n  \u003cli\u003eInsulation \u003cstrong\u003eXLPE\u003c\/strong\u003e 90 °C and \u003cstrong\u003eLSZH\u003c\/strong\u003e halogen-free sheath.\u003c\/li\u003e\n  \u003cli\u003eFire reaction: \u003cstrong\u003eCPR Cca-s1b,d1,a1\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eInstallation: indoor, outdoor, on tray, in conduit, or buried duct.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvantages or Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower voltage drop\u003c\/strong\u003e and higher current capacity compared to 4 mm².\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCPR safety\u003c\/strong\u003e with low smoke emission and zero halogen content.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutstanding manageability\u003c\/strong\u003e due to class 5 conductor and favorable bending radii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal and mechanical durability\u003c\/strong\u003e inherent to XLPE.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCustom supply\u003c\/strong\u003e thanks to sale by the meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurpose or Applications\u003c\/h3\u003e\n\u003cp\u003ePower supply and branch circuits between panels, risers, and internal networks in buildings and warehouses; \u003cem\u003eAC\u003c\/em\u003e distribution in solar plants (from inverters to panels\/transformer stations) when 6 mm² per conductor is required due to distance or current.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDesignation\u003c\/td\u003e\n\u003ctd\u003eRZ1-K (AS) · XLPE\/LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUNE 21123-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNo. of conductors\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCross-section\u003c\/td\u003e\n\u003ctd\u003e4 × 6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eClass 5 copper (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConductor resistance (20 °C)\u003c\/td\u003e\n\u003ctd\u003e≈ 3.30 Ω\/km per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated \/ test voltage\u003c\/td\u003e\n\u003ctd\u003e0.6\/1 kV · 3.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eService temperature\u003c\/td\u003e\n\u003ctd\u003e−15…+90 °C (250 °C\/5 s in short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFire reaction (CPR)\u003c\/td\u003e\n\u003ctd\u003eCca-s1b,d1,a1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003eLSZH halogen-free\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSheath color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePresentation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSold by the meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibilities\u003c\/h3\u003e\n\u003cp\u003eCompatible with ferrules\/terminals for 6 mm², metric cable glands, and standard conduits (pipe, tray, trench). Size protections and cross-section according to REBT\/ITC-BT, admissible currents, and voltage drop calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRZ1-K Green Hose 4x6mm² Halogen-Free 0.6\/1kV\u003c\/strong\u003e offers CPR safety, high manageability, and electrical capacity for reliable and durable low voltage wiring.\u003c\/p\u003e","brand":"Revi","offers":[{"title":"Default Title","offer_id":51503331639637,"sku":"REVICAB043","price":6.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0252\/6805\/files\/MANGUERA-4-HILOS-RZ1_744daf99-d4a4-4e2a-817a-00bbea09f897.png?v=1762630080"}],"url":"https:\/\/aurensol.net\/en\/collections\/cables-mangueras.oembed","provider":"Aurensol","version":"1.0","type":"link"}