{"title":"Hybrid Surface Pumps","description":"\u003c!-- ===================== COLLECTION: HYBRID SURFACE PUMPS — LONG DESCRIPTION (SEO, UPDATED) ===================== --\u003e\n\u003ch2\u003eWhat are hybrid surface pumps and what are they used for?\u003c\/h2\u003e\n\u003cp\u003eThese are pumps installed outside the water that draw from \u003cem\u003etanks or sumps\u003c\/em\u003e and can operate with both \u003cstrong\u003esolar energy\u003c\/strong\u003e and \u003cstrong\u003esingle-phase 230 V AC\u003c\/strong\u003e. The hybrid electronics prioritize solar and switch to 230 V when irradiation does not cover the \u003cstrong\u003eoperating point\u003c\/strong\u003e (flow rate and TDH), ensuring continuity in transfers, irrigation, and local pressurization. In our catalog, hybridization is implemented with \u003cstrong\u003eLorentz PowerPack\u003c\/strong\u003e (PP2000S\/PP4000AC\/PP600H) on Lorentz PS2 solar pumps and with \u003cstrong\u003eZIRI controllers\u003c\/strong\u003e for protection\/dual input for their DC series.\u003c\/p\u003e\n\n\u003ch3\u003eAdvantages and limitations\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh availability\u003c\/strong\u003e: operates on solar and maintains service with \u003cstrong\u003e230 V single-phase\u003c\/strong\u003e on cloudy days or during peaks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: prioritizes photovoltaic to reduce consumption and costs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical simplicity\u003c\/strong\u003e: backup with grid\/generator \u003cstrong\u003eonly 230 V single-phase\u003c\/strong\u003e (not three-phase).\u003c\/li\u003e\n  \u003cli\u003eLimitations: requires correct configuration of switching and DC\/AC protections; suction lift is limited (see “Best practices”).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransfers\u003c\/strong\u003e between tanks\/ponds and filling of cisterns.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIrrigation\u003c\/strong\u003e by drip or sprinkler from a tank or surface intake.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal pressurization\u003c\/strong\u003e of auxiliary lines (wash areas, hoses, remote points).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to choose your hybrid surface pump\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating point\u003c\/strong\u003e: define flow rate (m³\/h) and \u003cstrong\u003eTDH\u003c\/strong\u003e (m). TDH = static head + friction losses (pipes, elbows, valves, and filters). Select by the model’s \u003cem\u003eflow–head curve\u003c\/em\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHydraulics\u003c\/strong\u003e: centrifugal (CS-F\/CPM\/QB\/SHF) for medium–high flow rates and low–medium heads; \u003cstrong\u003ehigh pressure\/BOOST\u003c\/strong\u003e options for greater head with moderate flow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectronics\u003c\/strong\u003e:\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLorentz PS2 + PowerPack\u003c\/strong\u003e (PP2000S\/PP4000AC\/PP600H): converts PS2 solar units into \u003cem\u003ehybrid\u003c\/em\u003e systems with \u003cstrong\u003e230 V single-phase\u003c\/strong\u003e input.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eZIRI hybrid\u003c\/strong\u003e: use of \u003ca href=\"\/en\/collections\/accesorios-para-bombas\"\u003eZIRI controllers\u003c\/a\u003e to combine DC and \u003cstrong\u003e230 V single-phase\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC backup supply\u003c\/strong\u003e: exclusively \u003cstrong\u003e230 V single-phase\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction\u003c\/strong\u003e: minimize suction lift; install a foot valve and strainer. If the intake is deep, consider a \u003ca href=\"\/en\/collections\/bombas-sumergibles-hibridas\"\u003ehybrid submersible pump\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIndicative specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003ePriority solar DC + \u003cstrong\u003e230 V single-phase AC\u003c\/strong\u003e (backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlow range\u003c\/td\u003e\n\u003ctd\u003e~0.3–57 m³\/h (depending on CS-F\/CPM\/QB\/SHF\/BOOST series)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTotal dynamic head\u003c\/td\u003e\n\u003ctd\u003e~10–150 m (up to 150 m in high pressure\/BOOST)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eMPPT (solar), DC\/AC switching, optional VFD in AC loop if applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eDry run (probes\/press-control), non-return, DC isolation, DC\/AC surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCatalog status\u003c\/td\u003e\n\u003ctd\u003eHybrid lines expanding; Lorentz PowerPack and ZIRI controllers available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eBest installation practices\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlace the pump \u003cstrong\u003eclose to and below the water level\u003c\/strong\u003e to facilitate priming; use generous suction piping and avoid elbows.\u003c\/li\u003e\n  \u003cli\u003eEnable \u003cstrong\u003edry run\u003c\/strong\u003e shutdown and install a non-return valve on the discharge.\u003c\/li\u003e\n  \u003cli\u003eCorrectly configure \u003cstrong\u003esolar\/230 V switching\u003c\/strong\u003e and protections (PV isolator, surge protection, circuit breaker\/RCBO).\u003c\/li\u003e\n  \u003cli\u003eMaintenance plan: clean filters, check seals, tighten terminals, and periodically verify insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eComparisons and related accessories\u003c\/h3\u003e\n\u003cp\u003eIf you do not need backup and prioritize simplicity, see \u003ca href=\"\/en\/collections\/bombas-de-superficie-solares\"\u003eSolar Surface Pumps\u003c\/a\u003e. For pure AC, consider \u003ca href=\"\/en\/collections\/bombas-de-superficie-de-alterna\"\u003eAC Surface Pumps\u003c\/a\u003e. For deep water intake, see \u003ca href=\"\/en\/collections\/bombas-sumergibles-hibridas\"\u003eHybrid Submersible Pumps\u003c\/a\u003e. Complete the installation with \u003ca href=\"\/en\/collections\/accesorios-para-bombas\"\u003eAccessories\u003c\/a\u003e (foot valve, filters, Lorentz PowerPack\/ZIRI hybrid controllers, DC\/AC protections) and consult \u003ca href=\"\/en\/collections\/repuestos-para-bombas\"\u003eSpare Parts\u003c\/a\u003e when you need specific components.\u003c\/p\u003e","products":[],"url":"https:\/\/aurensol.net\/en\/collections\/bombas-de-superficie-hibridas.oembed","provider":"Aurensol","version":"1.0","type":"link"}